Cone-beam CT statistical reconstruction with a model for fluence modulation and electronic readout noise

Purpose: Cone-beam CT (CBCT) systems with a flat-panel detector (FPD) have advanced in a variety of specialty diagnostic imaging scenarios, with fluence modulation and multiple-gain detectors playing important roles in extending dynamic range and improving image quality. We present a penalized weighted least-squares (PWLS) reconstruction approach with a noise model that includes the effects of fluence modulation and electronic readout noise, and we show preliminary results that tests the concept with a CBCT head scanner prototype. Methods: Statistical weights in PWLS were modified using a realistic noise model for the FPD that considers factors such as system blur and spatially varying electronic noise in multiple-gain readout detectors (PWLSe). A spatially varying gain term was then introduced in the calculation of statistical weights to account for the change in quantum noise due to fluence modulation (e.g. bowtie filter) (PWLS∗). The methods were tested in phantom experiments involving an elliptical phantom specially designed to stress dual-gain readout, and a water phantom and an anthropomorphic head phantom to quantify improvements in noise-resolution characteristics for the new PWLS methods (PWLS𝑒 and PWLS∗, and combined PWLS∗e). The proposed methods were further tested using a high-quality, low-dose CBCT head scanner prototype in a clinical study involving patients with head injury. Results: Preliminary results show that the PWLSe method demonstrated superior noise-resolution tradeoffs compared to conventional PWLS, with variance reduced by ~15-25% at matched resolution of 0.65 mm edge-spread-function (ESF) width. Clinical studies confirmed these findings, with variance reduced by ~15% in peripheral regions of the head without loss in spatial resolution, improving visual image quality in detection of peridural hemorrhage. A bowtie filter and polyenergetic gain correction improved image uniformity, and early results demonstrated that the proposed PWLS∗ method showed a ~40% reduction in variance compared to conventional PWLS when used with a bowtie filter. Conclusion: A more accurate noise model incorporated in PWLS statistical weights to account for fluence modulation and electronic readout noise reduces image noise and improves soft-tissue imaging performance in CBCT for clinical applications requiring a high degree of contrast resolution.

[1]  J H Siewerdsen,et al.  Modeling and design of a cone-beam CT head scanner using task-based imaging performance optimization , 2016, Physics in medicine and biology.

[2]  Richard E. Colbeth,et al.  Multiple-gain-ranging readout method to extend the dynamic range of amorphous silicon flat-panel imagers , 2004, SPIE Medical Imaging.

[3]  Aswin Mathews,et al.  Fluence-field modulated x-ray CT using multiple aperture devices , 2016, SPIE Medical Imaging.

[4]  Jeffrey H. Siewerdsen,et al.  Image quality, scatter, and dose in compact CBCT systems with flat and curved detectors , 2018, Medical Imaging.

[5]  Jeffrey A. Fessler Penalized weighted least-squares image reconstruction for positron emission tomography , 1994, IEEE Trans. Medical Imaging.

[6]  D. Yang,et al.  A dedicated cone-beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization. , 2011, Medical physics.

[7]  J. Boone,et al.  Dedicated breast CT: radiation dose and image quality evaluation. , 2001, Radiology.

[8]  Wenxiang Cong,et al.  Dynamic Bowtie Filter for Cone-Beam/Multi-Slice CT , 2014, PloS one.

[9]  Norbert J Pelc,et al.  The feasibility of a piecewise-linear dynamic bowtie filter. , 2013, Medical physics.

[10]  J Yorkston,et al.  Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology. , 1997, Medical physics.

[11]  J H Siewerdsen,et al.  Statistical reconstruction for cone-beam CT with a post-artifact-correction noise model: application to high-quality head imaging , 2015, Physics in medicine and biology.

[12]  Wojciech Zbijewski,et al.  Evaluation of detector readout gain mode and bowtie filters for cone-beam CT imaging of the head. , 2016, Physics in medicine and biology.