Optimization-Based Formulations for Short-Circuit Studies with Inverter-Interfaced Generation in PowerModelsProtection.jl

Protecting inverter-interfaced microgrids is challenging as conventional time-overcurrent protection becomes unusable due to the lack of fault current. There is a great need for novel protective relaying methods that enable the application of protection coordination on microgrids, thereby allowing for microgrids with larger areas and numbers of loads while not compromising reliable power delivery. Tools for modeling and analyzing such microgrids under fault conditions are necessary in order to help design such protective relaying and operate microgrids in a configuration that can be protected, though there is currently a lack of tools applicable to inverter-interfaced microgrids. This paper introduces the concept of applying an optimization problem formulation to the topic of inverter-interfaced microgrid fault modeling, and discusses how it can be employed both for simulating short-circuits and as a set of constraints for optimal microgrid operation to ensure protective device coordination.

[1]  J.W. Bialek,et al.  Direct incorporation of fault level constraints in optimal power flow as a tool for network capacity analysis , 2005, IEEE Transactions on Power Systems.

[2]  Jaehee Lee,et al.  Integrated Generation Capacity and Transmission Network Expansion Planning With Superconducting Fault Current Limiter (SFCL) , 2013, IEEE Transactions on Applied Superconductivity.

[3]  Fan Zhang,et al.  Analysis of the Fault Characteristics of Microgrid with Inverter-Interfaced Distributed Generators , 2019, 2019 IEEE 8th International Conference on Advanced Power System Automation and Protection (APAP).

[4]  Lambros Ekonomou,et al.  Protection Schemes of Meshed Distribution Networks for Smart Grids and Electric Vehicles , 2018, Energies.

[5]  Russell Bent,et al.  PowerModels.J1: An Open-Source Framework for Exploring Power Flow Formulations , 2017, 2018 Power Systems Computation Conference (PSCC).

[6]  Hatem H. Zeineldin,et al.  Optimal Protection Coordination for Meshed Distribution Systems With DG Using Dual Setting Directional Over-Current Relays , 2016, IEEE Transactions on Smart Grid.

[7]  T. M. Jahns,et al.  Comparison of Grid Following and Grid Forming Control for a High Inverter Penetration Power System , 2018, 2018 IEEE Power & Energy Society General Meeting (PESGM).

[8]  Wei Lee Woon,et al.  Optimal Protection Coordination for Microgrids With Grid-Connected and Islanded Capability , 2012 .

[9]  Sung-Kwan Joo,et al.  Fault Current Constrained Decentralized Optimal Power Flow Incorporating Superconducting Fault Current Limiter (SFCL) , 2011, IEEE Transactions on Applied Superconductivity.

[10]  Guido Carpinelli,et al.  Three-phase photovoltaic generators modeling in unbalanced short-circuit operating conditions , 2019 .

[11]  Hatem H. Zeineldin,et al.  Transient Stability Constrained Protection Coordination for Distribution Systems With DG , 2018, IEEE Transactions on Smart Grid.

[12]  Graeme Burt,et al.  Approaches to Network Protection for Inverter Dominated Electrical Distribution Systems , 2006 .

[13]  Jay Johnson,et al.  Fault Current Experimental Results of Photovoltaic Inverters Operating with Grid-Support Functionality , 2018, 2018 IEEE 7th World Conference on Photovoltaic Energy Conversion (WCPEC) (A Joint Conference of 45th IEEE PVSC, 28th PVSEC & 34th EU PVSEC).

[14]  Mojtaba Khederzadeh,et al.  A novel approach to increase FCL application in preservation of over-current relays coordination in presence of asynchronous DGs , 2013 .

[15]  Carleton Coffrin,et al.  PowerModelsRestoration.jl: An Open-Source Framework for Exploring Power Network Restoration Algorithms , 2020, ArXiv.

[16]  V. Vita,et al.  Linguistic Representation of Power System Signals , 2016 .

[17]  Carleton Coffrin,et al.  PowerModelsDistribution.jl: An Open-Source Framework for Exploring Distribution Power Flow Formulations , 2020, ArXiv.

[18]  E. Muljadi,et al.  Dynamic Model Validation of PV Inverters under Short-Circuit Conditions , 2013, 2013 IEEE Green Technologies Conference (GreenTech).

[19]  Mehdi Savaghebi,et al.  Modeling, Analysis, and Design of Stationary-Reference-Frame Droop-Controlled Parallel Three-Phase Voltage Source Inverters , 2013, IEEE Transactions on Industrial Electronics.

[20]  Mark O'Malley,et al.  Optimal allocation of embedded generation on the Irish distribution network , 2005 .

[21]  Manohar Singh,et al.  Adaptive protection coordination scheme for power networks under penetration of distributed energy resources , 2016 .

[22]  Eduardo Cotilla Sanchez,et al.  Analyzing and Mitigating the Impacts of GMD and EMP Events on the Electrical Grid with PowerModelsGMD.jl , 2021, ArXiv.

[23]  Zhe Chen,et al.  Modeling of Grid-Forming and Grid-Following Inverters for Dynamic Simulation of Large-Scale Distribution Systems , 2021, IEEE Transactions on Power Delivery.

[24]  Y. Pan,et al.  Impact of inverter interfaced distributed generation on overcurrent protection in distribution systems , 2011, 2011 IEEE Power Engineering and Automation Conference.

[25]  W. H. Kersting Radial distribution test feeders , 1991 .

[26]  Jai Govind Singh,et al.  Short circuit current level reduction in power system by optimal placement of fault current limiter , 2017 .

[27]  Timothy C. Green,et al.  Comparison of Current-Limiting Strategies During Fault Ride-Through of Inverters to Prevent Latch-Up and Wind-Up , 2014, IEEE Transactions on Power Electronics.

[28]  Timothy C. Green,et al.  Fault models of inverter-interfaced distributed generators: Experimental verification and application to fault analysis , 2011, 2011 IEEE Power and Energy Society General Meeting.

[29]  Abraham Ellis,et al.  Contribution of photovoltaic power generation systems to AC short circuits — A survey of current modeling practices and challenges , 2013, 2013 IEEE 39th Photovoltaic Specialists Conference (PVSC).

[30]  Qiushi Cui,et al.  A Microgrid Protection Scheme with Conventional Relay Measurements , 2018, 2018 IEEE Power & Energy Society General Meeting (PESGM).

[31]  Yilu Liu,et al.  Fault Characteristics of Distributed Solar Generation , 2020, IEEE Transactions on Power Delivery.

[32]  Saeed Lotfifard,et al.  Sparsity-Based Short-Circuit Analysis of Power Distribution Systems With Inverter Interfaced Distributed Generators , 2019, IEEE Transactions on Power Systems.

[33]  Ehab F. El-Saadany,et al.  Optimal Protection Coordination for Microgrids Considering N $-$1 Contingency , 2017, IEEE Transactions on Industrial Informatics.

[34]  Wook Kim,et al.  Fault Current Constraint Transmission Expansion Planning Based on the Inverse Matrix Modification Lemma and a Valid Inequality , 2019 .

[35]  Tianshu Bi,et al.  Theoretical Analysis on the Short-Circuit Current of Inverter-Interfaced Renewable Energy Generators with Fault-Ride-Through Capability , 2017 .

[36]  G. Carpinelli,et al.  Impact of Photovoltaic Generators on the Three Phase Short Circuit Operating Conditions , 2018, 2018 IEEE International Conference on Environment and Electrical Engineering and 2018 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe).

[37]  Frede Blaabjerg,et al.  Step-by-step design procedure for a grid-connected three-phase PWM voltage source converter , 2004 .

[38]  Sadegh Jamali,et al.  Non-communication protection method for meshed and radial distribution networks with synchronous-based DG , 2017 .

[39]  Adam Summers,et al.  Simulation of Grid-Forming Inverters Dynamic Models using a Power Hardware-in-the-Loop Testbed , 2019, 2019 IEEE 46th Photovoltaic Specialists Conference (PVSC).

[40]  Tae-Sun Kim,et al.  A network reconfiguration algorithm for the reduction of expected fault currents , 2013, 2013 IEEE Power & Energy Society General Meeting.

[41]  Amirhossein Khazali,et al.  Optimal power flow considering fault current level constraints and fault current limiters , 2014 .

[42]  Ali Bidram,et al.  Optimal Protection Relay Placement in Microgrids , 2020, 2020 IEEE Kansas Power and Energy Conference (KPEC).

[43]  Adam Summers,et al.  Grid-forming Inverter Experimental Testing of Fault Current Contributions , 2019, 2019 IEEE 46th Photovoltaic Specialists Conference (PVSC).

[44]  Janusz Bialek,et al.  Impact of Fault Level Constraints on the Economic Operation of Power Systems , 2006 .

[45]  F. Blaabjerg,et al.  Control of Power Converters in AC Microgrids , 2012, IEEE Transactions on Power Electronics.

[46]  Bijaya K. Panigrahi,et al.  Optimal location, size and protection coordination of distributed generation in distribution network , 2013, 2013 IEEE Symposium on Swarm Intelligence (SIS).

[47]  Alan Edelman,et al.  Julia: A Fast Dynamic Language for Technical Computing , 2012, ArXiv.

[48]  Farrokh Aminifar,et al.  MILP Formulation for Transmission Expansion Planning With Short-Circuit Level Constraints , 2016, IEEE Transactions on Power Systems.

[49]  A. P. Sakis Meliopoulos,et al.  Setting-Less Protection: Feasibility Study , 2013, 2013 46th Hawaii International Conference on System Sciences.

[50]  Yong Kang,et al.  Short-Circuit Fault Protection Strategy for High-Power Three-Phase Three-Wire Inverter , 2012, IEEE Transactions on Industrial Informatics.

[51]  Susmita Kar,et al.  Time-frequency transform-based differential scheme for microgrid protection , 2014 .

[52]  Insu Kim,et al.  Short-Circuit Analysis Models for Unbalanced Inverter-Based Distributed Generation Sources and Loads , 2019, IEEE Transactions on Power Systems.

[53]  Dmitry Shchetinin,et al.  Optimization-Based Settingless Algorithm Combining Protection and Fault Identification , 2020, IEEE Transactions on Power Delivery.

[54]  Arindam Ghosh,et al.  Networked Microgrids: State-of-the-Art and Future Perspectives , 2019, IEEE Transactions on Industrial Informatics.