A new automatic phase mask filter for high-resolution brain venography at 3 T: theoretical background and experimental validation.

To improve vessel contrast in high-resolution susceptibility-based brain venography, an automatic phase contrast enhancing procedure is proposed, based on a new phase mask filter suitable for maximizing contrast of venous MR signals. The effectiveness of the new approach was assessed both on digital phantoms and on acquired MR human brain images, and then compared with venographic results of phase masking methods in recent literature. The digital phantom consisted of a simulated MR dataset with given signal-to-noise ratios (SNRs), while real human data were collected by scanning healthy volunteers with a 3.0-T MR system and a 3D gradient echo pulse sequence. The new phase mask (NM) was more effective than the conventional mask (CM) both on the digital phantoms and on the acquired MR images. A quantitative comparison based on phantom venograms indicates how this phase enhancement can lead to a significant increase in the contrast-to-noise ratio (CNR) for all considered phase values as well as for all vessel sizes of clinical interest. Likewise, the in vivo brain venograms reveal a better depiction of the smallest venous vessels and the enhancement of many details undetectable in conventional venograms.

[1]  E. Haacke,et al.  High‐resolution BOLD venographic imaging: a window into brain function , 2001, NMR in biomedicine.

[2]  J R Reichenbach,et al.  High-Resolution MR Venography at 3.0 Tesla , 2000, Journal of computer assisted tomography.

[3]  Andreas Greiser,et al.  The sign convention for phase values on different vendor systems: definition and implications for susceptibility-weighted imaging. , 2010, Magnetic resonance imaging.

[4]  L R Schad,et al.  Improved target volume characterization in stereotactic treatment planning of brain lesions by using high‐resolution BOLD MR‐venography , 2001, NMR in biomedicine.

[5]  L R Schad,et al.  Comparison of functional MR-venography and EPI-BOLD fMRI at 1.5 T. , 1998, Magnetic resonance imaging.

[6]  M. Pui,et al.  Cerebral MR venography. , 2004, Clinical imaging.

[7]  J Debus,et al.  [High resolution MR-venography of cerebral arteriovenous malformations]. , 1999, Der Radiologe.

[8]  Sergio Casciaro,et al.  Quantification of venous blood signal contribution to BOLD functional activation in the auditory cortex at 3 T. , 2008, Magnetic resonance imaging.

[9]  Ravi S. Menon,et al.  Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[10]  Yu-Chung N. Cheng,et al.  Susceptibility weighted imaging (SWI) , 2004, Zeitschrift fur medizinische Physik.

[11]  A. Bikfalvi,et al.  Molecular mechanisms of tumor vascularization. , 2005, Critical reviews in oncology/hematology.

[12]  E M Haacke,et al.  Artery and vein separation using susceptibility‐dependent phase in contrast‐enhanced MRA , 2000, Journal of magnetic resonance imaging : JMRI.

[13]  Lothar R. Schad,et al.  High-resolution venography of the brain using magnetic resonance imaging , 1998, Magnetic Resonance Materials in Physics, Biology and Medicine.

[14]  R. Edelman,et al.  Magnetic resonance imaging (2) , 1993, The New England journal of medicine.

[15]  W. Lin,et al.  MR high-resolution blood oxygenation level-dependent venography of occult (low-flow) vascular lesions. , 1999, AJNR. American journal of neuroradiology.

[16]  Yingbiao Xu,et al.  The role of voxel aspect ratio in determining apparent vascular phase behavior in susceptibility weighted imaging. , 2006, Magnetic resonance imaging.

[17]  Michael Lim,et al.  New vessel formation in the central nervous system during tumor growth, vascular malformations, and Moyamoya. , 2006, Current neurovascular research.

[18]  Song Lai,et al.  Spatial Selectivity of BOLD Contrast: Effects In and Around Draining Veins , 2000 .

[19]  S. Ogawa,et al.  Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields , 1990, Magnetic resonance in medicine.

[20]  J R Reichenbach,et al.  Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent. , 1997, Radiology.