Direct determination of amino acids and carbohydrates by high-performance capillary electrophoresis with refractometric detection.

This is an initial report to propose a novel approach in high-performance capillary electrophoresis (HPCE) for the direct detection of compounds without natural absorbance in the UV and visible spectral range, such as amino acids and carbohydrates. A refractometry detector with the 2 nl cell (Applied Systems, Minsk, Belarus) was employed to identify amino acids and carbohydrates without derivatization. The first results are provided on separation of seven free amino acids in the phosphate running buffer and three free carbohydrates in the borate-sodium dodecyl sulfate running buffer and detection by refractometer. Fused capillaries of 50 or 75 microm internal diameter and separation voltage (10-23 kV) were applied. Detection limits ranged typically from 10 to 100 fmol and the response was linear over two orders of magnitude for most of the amino acids and carbohydrates. The HPCE system demonstrated good long-term stability and reproducibility with a relative standard deviation, less than 5% for the migration time (n=10).

[1]  P. Oefner,et al.  Indirect UV detection of carbohydrates in capillary zone electrophoresis , 1992 .

[2]  K. Yokoi,et al.  Determination of amino acids by high-performance capillary electrophoresis with on-line mode in-capillary derivatization , 1997 .

[3]  Tomoyoshi Soga,et al.  Simultaneous determination of inorganic anions, organic acids, amino acids and carbohydrates by capillary electrophoresis , 1999 .

[4]  E. Yeung,et al.  Diode laser-induced fluorescence detection in capillary electrophoresis after pre-column derivatization of amino acids and small peptides. , 1995, Journal of chromatography. A.

[5]  A. Guttman,et al.  Analysis of monosaccharide composition by capillary electrophoresis. , 1997, Journal of chromatography. A.

[6]  Janusz Pawliszyn,et al.  Nanoliter volume sequential differential concentration gradient detector , 1988 .

[7]  S. Lunte,et al.  Direct determination of amino acids by capillary electrophoresis/electrochemistry using a copper microelectrode and zwitterionic buffers , 1995, Electrophoresis.

[8]  T. Soga,et al.  Simultaneous determination of monosaccharides in glycoproteins by capillary electrophoresis. , 1998, Analytical biochemistry.

[9]  T.-I. Lin,et al.  Capillary electrophoretic determination of amino acids. Improvement by cyclodextrin additives , 1995 .

[10]  I. Nazimov,et al.  Identification of unusual (modified and non-encoded) amino acid residues in peptides by combinations of high-performance liquid chromatography and high-performance capillary electrophoresis with matrix-assisted laser desorption ionization time-of-flight mass spectrometry. , 2000, Journal of chromatography. A.

[11]  F. Bossa,et al.  Automated amino acid analysis using precolumn derivatization with dansylchloride reversed-phase high-performance liquid chromatography , 1990 .

[12]  J. Pawliszyn Concentration Gradient Detector in Capillary Separation Technology , 1987 .

[13]  S. Ganno,et al.  Fluorimetric determination of reducing carbohydrates with 2-cyanoacetamide and application to automated analysis of carbohydrates as borate complexes. , 1980 .

[14]  T. Imasaka,et al.  Determination of cyanine-labeled amino acid enantiomers by cyclodextrin-modified capillary gel electrophoresis combined with diode laser fluorescence detection , 1998 .

[15]  H. Wan,et al.  Direct and indirect chiral separation of amino acids by capillary electrophoresis , 1995 .

[16]  T. Soga,et al.  Determination of carbohydrates by hydrophilic interaction chromatography with pulsed amperometric detection using postcolumn pH adjustment , 1992 .

[17]  Z. El Rassi,et al.  Recent developments in capillary electrophoresis of carbohydrate species , 1997, Electrophoresis.

[18]  D. Bornhop,et al.  Universal detection in capillary electrophoresis with a micro-interferometric backscatter detector , 1999 .

[19]  S. Terabe,et al.  Separation of 24 dansylamino acids by capillary electrophoresis with a non-ionic surfactant. , 1994, Journal of chromatography. A.

[20]  H. Takemoto,et al.  Microquantitative analysis of neutral and amino sugars as fluorescent pyridylamino derivatives by high-performance liquid chromatography. , 1985, Analytical biochemistry.

[21]  W. Faubel,et al.  Fiber optic modified thermal lens detector system for the determination of amino acids , 1998 .

[22]  H. Salimi-Moosavi,et al.  Selectivity control in the non-aqueous capillary electrophoretic separation of amino acids , 1997 .

[23]  R. M. Seifar,et al.  Application of capillary electrochromatography to the separation of phenylthiohydantoin-amino acids , 1999 .

[24]  L. P. Milligan,et al.  Improved sugar separation by high-performance liquid chromatography using porous microparticle carbohydrate columns , 1981 .

[25]  S. Michaelsen,et al.  Analysis of dansyl amino acids in feedstuffs and skin by micellar electrokinetic capillary chromatography. , 1994, Journal of chromatography. A.

[26]  J. Nakamura,et al.  High-performance liquid chromatography of reducing carbohydrates as strongly ultraviolet-absorbing and electrochemically sensitive 1-phenyl-3-methyl-5-pyrazolone derivatives. , 1989, Analytical biochemistry.

[27]  Y-H. Lee,et al.  Capillary electrophoretic determination of amino acids with indirect absorbance detection , 1994 .