Influence of the cantilever holder on the vibrations of AFM cantilevers

Dynamic techniques exploiting the vibration of atomic force microscope (AFM) cantilevers are often superior to quasi-static operation, in particular with respect to the signal-to-noise ratio. Tapping mode, magnetic force microscopy or torsional resonance (TR)-mode for example exploit the resonance amplification of bending or torsional modes of the cantilever. In atomic force acoustic microscopy (AFAM) and related techniques aiming to measure elasticity or adhesion quantitatively on a nanometre scale, the cantilever vibrates while the tip is in contact with a sample surface. The higher vibration modes are included in the evaluation. Well-defined resonance maxima of the cantilever are a prerequisite for all resonance techniques. To allow their handling, microscaled commercial cantilevers are fabricated in one piece with a holder of millimetre dimensions providing the base to which the cantilever beam is suspended. Here, we examine experimentally and theoretically how the cantilever holder influences the vibration of the cantilevers.

[1]  D. Rugar,et al.  Magnetic Force Microscopy (MFM) , 1992 .

[2]  J. D. Adams,et al.  Reduction of spurious resonance peaks in microcantilever tuning through substrate contact surface reduction , 2004 .

[3]  E. Dupas,et al.  High-frequency mechanical spectroscopy with an atomic force microscope , 2001 .

[4]  Ryutaro Maeda,et al.  Evaluation of the Elastic Properties of a Cantilever Using Resonant Frequencies , 1997 .

[5]  Othmar Marti,et al.  Combined scanning force and friction microscopy of mica , 1990 .

[6]  Robert W. Stark,et al.  Determination of shear stiffness based on thermal noise analysis in atomic-force microscopy: Passive overtone microscopy , 2001 .

[7]  Joseph A. Turner,et al.  Imaging of flexural and torsional resonance modes of atomic force microscopy cantilevers using optical interferometry , 2003 .

[8]  U. Hartmann Magnetic force microscopy , 1990 .

[9]  Kazushi Yamanaka,et al.  Quantitative material characterization by ultrasonic AFM , 1999 .

[10]  Ute Rabe,et al.  Vibrations of free and surface‐coupled atomic force microscope cantilevers: Theory and experiment , 1996 .

[11]  W. Arnold,et al.  Atomic Force Microscopy with Lateral Modulation , 2004 .

[12]  Jonathan S. Colton,et al.  Characterization of microcantilevers solely by frequency response acquisition , 2005 .

[13]  P. Vairac,et al.  Electromechanical resonator in scanning microdeformation microscopy: theory and experiment , 1999 .

[14]  Joseph A. Turner,et al.  Imaging using lateral bending modes of atomic force microscope cantilevers , 2004 .

[15]  Bharat Bhushan,et al.  Imaging and measurement of elasticity and friction using the TRmode , 2005 .

[16]  Mathias Göken,et al.  Imaging and measurement of local mechanical material properties by atomic force acoustic microscopy , 2002 .

[17]  G. Lévêque,et al.  Vibration of the cantilever in Force Modulation Microscopy analysis by a finite element model , 2003 .