Noncontact RF Vital Sign Sensor for Continuous Monitoring of Driver Status

In this paper, a radio frequency vital sign sensor based on double voltage-controlled oscillators (VCOs) combined with a switchable phase-locked loop (PLL) is proposed for a noncontact remote vital sign sensing system. Our sensing system primarily detects the periodic movements of the human lungs and the hearts via the impedance variation of the resonator. With a change in impedance, both the VCO oscillation frequency and the PLL feedback voltage also change. Thus, by tracking the feedback voltage of the PLL, breath and heart rate signals can be acquired simultaneously. However, as the distance between the body and the sensor varies, there are certain points with minimal sensitivity, making it is quite difficult to detect vital signs. These points, called impedance null points, periodically occur at distances proportional to the wavelength. To overcome the impedance null point problem, two resonators operating at different frequencies, 2.40 and 2.76 GHz, are employed as receiving components. In an experiment to investigate the sensing performance as a function of distance, the measurement distance was accurately controlled by a linear actuator. Furthermore, to evaluate the sensing performance in a real environment, experiments were carried out with a male and a female subject in a static vehicle. To demonstrate the real-time vital sign monitoring capability, spectrograms were utilized, and the accuracy was assessed relative to reference sensors. Based on the results, it is demonstrated that the proposed remote sensor can reliably detect vital signs in a real vehicle environment.

[1]  Giovanni Corsini,et al.  A Single On-Body Antenna as a Sensor for Cardiopulmonary Monitoring , 2010, IEEE Antennas and Wireless Propagation Letters.

[2]  Hans P A Van Dongen,et al.  Efficient driver drowsiness detection at moderate levels of drowsiness. , 2013, Accident; analysis and prevention.

[3]  Y. Kim,et al.  Through-Wall Human Tracking With Multiple Doppler Sensors Using an Artificial Neural Network , 2009, IEEE Transactions on Antennas and Propagation.

[4]  Roc Berenguer,et al.  Full Passive UHF Tag With a Temperature Sensor Suitable for Human Body Temperature Monitoring , 2010, IEEE Transactions on Circuits and Systems II: Express Briefs.

[5]  Changzhi Li,et al.  A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[6]  Jinhong Guo,et al.  Clinical identification of diabetic ketosis/diabetic ketoacidosis acid by electrochemical dual channel test strip with medical smartphone , 2018, Sensors and Actuators B: Chemical.

[7]  Yong Gyu Lim,et al.  ECG Recording on a Bed During Sleep Without Direct Skin-Contact , 2007, IEEE Transactions on Biomedical Engineering.

[8]  Jinhong Guo,et al.  Uric Acid Monitoring with a Smartphone as the Electrochemical Analyzer. , 2016, Analytical chemistry.

[9]  Enrique Medina,et al.  Drowsiness Detection Based on the Analysis of Breathing Rate Obtained from Real-time Image Recognition , 2016 .

[10]  Chin-Lung Yang,et al.  Wearable sensors based on a high sensitive complementary split-ring resonator for accurate cardiorespiratory sign measurements , 2017, 2017 IEEE MTT-S International Microwave Symposium (IMS).

[11]  Steffen Leonhardt,et al.  A Multisensor Implant for Continuous Monitoring of Intracranial Pressure Dynamics , 2012, IEEE Transactions on Biomedical Circuits and Systems.

[12]  Sun Yanfeng,et al.  Yawning Detection Based on Gabor Wavelets and LDA , 2009 .

[13]  Jong-Gwan Yook,et al.  Real-time Humidity Sensor Based on Microwave Resonator Coupled with PEDOT:PSS Conducting Polymer Film , 2018, Scientific Reports.

[14]  Tsuyoshi Kato,et al.  Capacitive Sensing of Electrocardiographic Potential Through Cloth From the Dorsal Surface of the Body in a Supine Position: A Preliminary Study , 2007, IEEE Transactions on Biomedical Engineering.

[15]  A. Porch,et al.  Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor , 2015, IEEE Transactions on Microwave Theory and Techniques.

[16]  Minah Suh,et al.  Real-time in vivo two-photon imaging study reveals decreased cerebro-vascular volume and increased blood-brain barrier permeability in chronically stressed mice , 2018, Scientific Reports.

[17]  Ajay Mittal,et al.  Head movement-based driver drowsiness detection: A review of state-of-art techniques , 2016, 2016 IEEE International Conference on Engineering and Technology (ICETECH).

[18]  Gi-Ho Yun,et al.  Temperature-Corrected Fluidic Glucose Sensor Based on Microwave Resonator , 2018, Sensors.

[19]  Sangdong Kim,et al.  Low-Complexity Joint Extrapolation-MUSIC-Based 2-D Parameter Estimator for Vital FMCW Radar , 2019, IEEE Sensors Journal.

[20]  Sang-Gyu Kim,et al.  A Label-Free Biosensing Platform Using a PLL Circuit and Biotin-Streptavidin Binding System. , 2015, IEEE transactions on biomedical circuits and systems.

[21]  J. Yook,et al.  A real-time humidity sensor based on a microwave oscillator with conducting polymer PEDOT:PSS film , 2019, Sensors and Actuators B: Chemical.

[22]  Sang-Gyu Kim,et al.  Noncontact Proximity Vital Sign Sensor Based on PLL for Sensitivity Enhancement , 2014, IEEE Transactions on Biomedical Circuits and Systems.

[23]  Toshiyo Tamura,et al.  Wearable Photoplethysmographic Sensors—Past and Present , 2014 .

[24]  Jinhong Guo,et al.  Smartphone-Powered Electrochemical Biosensing Dongle for Emerging Medical IoTs Application , 2018, IEEE Transactions on Industrial Informatics.

[25]  Jong-Gwan Yook,et al.  A highly sensitive and label free biosensing platform for wireless sensor node system. , 2013, Biosensors & bioelectronics.

[26]  Ivan Ho Mien,et al.  Heart rate variability can be used to estimate sleepiness-related decrements in psychomotor vigilance during total sleep deprivation. , 2012, Sleep.

[27]  Jinhong Guo,et al.  Smartphone-Powered Electrochemical Dongle for Point-of-Care Monitoring of Blood β-Ketone. , 2017, Analytical chemistry.

[28]  B. Tefft,et al.  Prevalence of motor vehicle crashes involving drowsy drivers, United States, 1999-2008. , 2012, Accident; analysis and prevention.

[29]  D. Samardzija,et al.  Doppler radar sensing of multiple subjects in single and multiple antenna systems , 2005, TELSIKS 2005 - 2005 uth International Conference on Telecommunication in ModernSatellite, Cable and Broadcasting Services.

[30]  Norbert Noury,et al.  A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising? , 2014 .

[31]  L. Downey,et al.  Stationary gaze entropy predicts lane departure events in sleep-deprived drivers , 2018, Scientific Reports.

[32]  Xing Ma,et al.  Simultaneous monitoring of glucose and uric acid on a single test strip with dual channels. , 2017, Biosensors & bioelectronics.

[33]  Lei Zhu,et al.  Gain-Enhanced Patch Antennas With Loading of Shorting Pins , 2016, IEEE Transactions on Antennas and Propagation.

[34]  Mahmoud Al Ahmad,et al.  Piezoelectric extraction of ECG signal , 2016, Scientific Reports.

[35]  Yong-Jun An,et al.  Sensitivity Enhanced Vital Sign Detection Based on Antenna Reflection Coefficient Variation , 2016, IEEE Transactions on Biomedical Circuits and Systems.

[36]  Adeel Ahmad,et al.  Vital signs monitoring of multiple people using a FMCW millimeter-wave sensor , 2018, 2018 IEEE Radar Conference (RadarConf18).

[37]  Gi-Ho Yun,et al.  Compact Vital Signal Sensor Using Oscillation Frequency Deviation , 2012, IEEE Transactions on Microwave Theory and Techniques.