Further calculations on field emission initiated vacuum breakdown

This letter reports calculations of breakdown field for vacuum gaps using the model previously discussed by Chatterton. In this case the effect of varying the electrode temperature at which primary instability could occur is examined. The results indicate that if comparison is to be made between theory and experiment the instability temperature must be known for the materials and configuration under consideration.