Signal quality measures for pulse oximetry through waveform morphology analysis

Pulse oximetry has been extensively used to estimate oxygen saturation in blood, a vital physiological parameter commonly used when monitoring a subject's health status. However, accurate estimation of this parameter is difficult to achieve when the fundamental signal from which it is derived, the photoplethysmograph (PPG), is contaminated with noise artifact induced by movement of the subject or the measurement apparatus. This study presents a novel method for automatic rejection of artifact contaminated pulse oximetry waveforms, based on waveform morphology analysis. The performance of the proposed algorithm is compared to a manually annotated gold standard. The creation of the gold standard involved two experts identifying sections of the PPG signal containing good quality PPG pulses and/or noise, in 104 fingertip PPG signals, using a simultaneous electrocardiograph (ECG) signal as a reference signal. The fingertip PPG signals were each 1 min in duration and were acquired from 13 healthy subjects (10 males and 3 females). Each signal contained approximately 20 s of purposely induced artifact noise from a variety of activities involving subject movement. Some unique waveform morphology features were extracted from the PPG signals, which were believed to be correlated with signal quality. A simple decision-tree classifier was employed to arrive at a classification decision, at a pulse-by-pulse resolution, of whether a pulse was of acceptable quality for use or not. The performance of the algorithm was assessed using Cohen's kappa coefficient (κ), sensitivity, specificity and accuracy measures. A mean κ of 0.64 ± 0.22 was obtained, while the mean sensitivity, specificity and accuracy were 89 ± 10%, 77 ± 19% and 83 ± 11%, respectively. Furthermore, a heart rate estimate, extracted from uncontaminated sections of PPG, as identified by the algorithm, was compared with the heart rate derived from an uncontaminated simultaneous ECG signal. The mean error between both heart rate readings was 0.49 ± 0.66 beats per minute (BPM), in comparison to an error value observed without using the artifact detection algorithm of 7.23 ± 5.78 BPM. These results demonstrate that automated identification of signal artifact in the PPG signal through waveform morphology analysis is achievable. In addition, a clear improvement in the accuracy of the derived heart rate is also evident when such methods are employed.

[1]  Peter R. Smith,et al.  A new method for pulse oximetry possessing inherent insensitivity to artifact , 2001, IEEE Transactions on Biomedical Engineering.

[2]  Yuan-Ting Zhang,et al.  An Efficient Motion-Resistant Method for Wearable Pulse Oximeter , 2008, IEEE Transactions on Information Technology in Biomedicine.

[3]  M. Petterson,et al.  Adaptive filtering and alternative calculations revolutionizes pulse oximetry sensitivity and specificity during motion and low perfusion , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  Steve Warren,et al.  Analysis and detection of motion artifact in photoplethysmographic data using higher order statistics , 2008, 2008 IEEE International Conference on Acoustics, Speech and Signal Processing.

[5]  L. G. Sison,et al.  Characterization and adaptive filtering of motion artifacts in pulse oximetry using accelerometers , 2002, Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology.

[6]  Conor Heneghan,et al.  Cardiorespiratory-based sleep staging in subjects with obstructive sleep apnea , 2006, IEEE Transactions on Biomedical Engineering.

[7]  D. Balasubramaniam,et al.  Implementation of ECG signal processing and analysis techniques in digital signal processor based system , 2009, 2009 IEEE International Workshop on Medical Measurements and Applications.

[8]  John M. Graybeal,et al.  The Effect of Motion on Pulse Oximetry and Its Clinical Significance , 2007, Anesthesia and analgesia.

[9]  X. Teng,et al.  The effect of contacting force on photoplethysmographic signals , 2004, Physiological measurement.

[10]  B. George,et al.  Motion Artifact Reduction and Data Compression of Photoplethysmo-graphic Signals utilizing Cycle by Cycle Fourier Series Analysis , 2008, 2008 IEEE Instrumentation and Measurement Technology Conference.

[11]  M. Nitzan,et al.  The measurement of oxygen saturation in arterial and venous blood , 2008, IEEE Instrumentation & Measurement Magazine.

[12]  Youngil Kim,et al.  Design of filter to reject motion artifact of pulse oximetry , 2004, Comput. Stand. Interfaces.

[13]  Stephen James Wilson,et al.  A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states , 2006, Medical and Biological Engineering and Computing.

[14]  Sandy Weininger,et al.  Development of a Standardized Method for Motion Testing in Pulse Oximeters , 2007, Anesthesia and analgesia.

[15]  T. L. Rusch,et al.  Signal processing methods for pulse oximetry , 1996, Comput. Biol. Medicine.

[16]  Nk Shah,et al.  Comparison of Three New Generation Pulse Oximeters during Motion and Low Perfusion in Volunteers , 2006 .

[17]  Jianchu Yao,et al.  A novel algorithm to separate motion artifacts from photoplethysmographic signals obtained with a reflectance pulse oximeter , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[18]  S J Barker,et al.  Effects of Motion on the Performance of Pulse Oximeters in Volunteers , 1996, Anesthesiology.

[19]  Michael R. Neuman,et al.  Motion Artifact In Pulse Oximetry , 1990, [1990] Proceedings of the Twelfth Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[20]  Hartmut Gehring,et al.  The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia. , 2002, Respiratory care.

[21]  K. Reddy,et al.  Motion Artifact Reduction in Photoplethysmographic Signals using Singular Value Decomposition , 2007, 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007.