Potassium selective CHEMFET based on an ion-partitioning membrane

Abstract The use of a novel type of electroactive ion-partitioning membrane is employed for the development of a potassium selective chemically modified field-effect transistor (CHEMFET). As is in the case of optodes, the membrane is doped with two ion carriers, one selective to the ion of interest (K+) and the other to protons. The careful optimization of the chemical composition of the membrane allows for ion-exchange to take place between the partitioned cation and the membrane protons. The potassium ions extracted into the bulk of the membrane phase displace protons of equal charge out of the membrane, and towards the sample solution and the pH-sensitive transducer. The potentiometric response of the sensor is based on the magnitude of this proton flux, as it is measured by the pH-ISFET. Both the effect of the ionic composition of the sample solution and the chemical constituents of the polymeric membrane are evaluated in relation to the potentiometric response of the CHEMFET. It is shown that the increase of the mole ratios of potassium to proton in the sample solution, the use of small amounts of a highly acidic proton carrier, and the use of a low dielectric constant plasticizer of the sensor to potassium ions. The performance of the K-CHEMFET developed based on the optimized ion-partitioning membrane is evaluated by the measurement of potassium levels in real blood serum samples.

[1]  M. Meyerhoff,et al.  Response properties of ion-selective polymeric membrane electrodes prepared with aminated and carboxylated poly(vinyl chloride). , 1988, Analytical chemistry.

[2]  Meng-Nian Niu,et al.  Effect of two types of surface sites on the characteristics of Si3N4-gate pH-ISFETs , 1996 .

[3]  P. Bühlmann,et al.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors. , 1998, Chemical reviews.

[4]  P Bergveld,et al.  Development of an ion-sensitive solid-state device for neurophysiological measurements. , 1970, IEEE transactions on bio-medical engineering.

[5]  E. Pretsch,et al.  Design of neutral hydrogen ion carriers for solvent polymeric membrane electrodes of selected pH range , 1986 .

[6]  P. Hauser,et al.  Optode for bulk-response membranes , 1990 .

[7]  Piet Bergveld,et al.  Chemically modified field effect transistors: the effect of ion-pair association on the membrane potentials , 1994 .

[8]  R. Buck,et al.  Carboxylated Poly(vinyl chloride) as a Substrate for Ion Sensors: Effects of Native Ion Exchange on Responses , 1994 .

[9]  M. D. Castro,et al.  Ion‐sensitive field‐effect transistors and ion‐selective electrodes as sensors in dynamic systems , 1995 .

[10]  A R Midgley,et al.  Electrochemical performance, biocompatibility, and adhesion of new polymer matrices for solid-state ion sensors. , 1991, Analytical chemistry.

[11]  Ernö Pretsch,et al.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics. , 1997, Chemical reviews.

[12]  A selfconsistent set of reference values , 1989 .

[13]  P. Hauptmann Sensors: A Comprehensive Survey , 1996 .

[14]  R. Buck,et al.  Anion effects on Donnan failure of aminated-poly(vinyl chloride)-based and neutral-carrier-based pH sensors , 1993 .

[15]  M. Grattarola,et al.  An atomic force microscope estimation of the point of zero charge of silicon insulators , 1998 .

[16]  D. Reinhoudt,et al.  Transduction of selective recognition of heavy metal ions by chemically modified field effect transistors (CHEMFETs) , 1992 .

[17]  John Aurie Dean,et al.  Lange's Handbook of Chemistry , 1978 .

[18]  J. Bartrolí,et al.  Continuous-Flow System for On-Line Water Monitoring Using Back-Side Contact ISFET-Based Sensors. , 1996, Analytical chemistry.

[19]  Karl Cammann,et al.  Novel membrane material for ion-selective field-effect transistors with extended lifetime and improved selectivity , 1996 .

[20]  Curtis C. Johnson,et al.  Potassium ion-sensitive field effect transistor , 1975 .

[21]  E. Bakker,et al.  Synthesis and characterization of neutral hydrogen ion-selective chromoionophores for use in bulk optodes , 1993 .