Miniaturization of plastic lens by injection molding for disposable endoscopie optical coherence tomography system

Minimally invasive robotic surgery required disposable endoscopie optical coherence tomography (OCT) for high-resolution deep tissue imaging and cross-contamination prevention. Here, we developed a miniaturized plastic lens by injection molding for developing a disposable endoscopie optical coherence tomography system for the first time. Injection molding provided low-cost and high-production rate to produce a disposable plastic lens and enabled the miniaturization of plastic lens. Transmittance and curvature of the plastic lens was measured. The plastic lens was integrated with an endoscopie OCT system, and the images of human-skin and microspheres embedded in agarose gel were captured. We are currently trying to integrate the plastic lens with a disposable endoscopie OCT system.

[1]  J. Fujimoto Optical coherence tomography for ultrahigh resolution in vivo imaging , 2003, Nature Biotechnology.

[2]  Alois Knoll,et al.  The Endo[PA]R system for minimally invasive robotic surgery , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[3]  Pietro Addeo,et al.  Robot-assisted laparoscopic pancreatic surgery: single-surgeon experience , 2010, Surgical Endoscopy.

[4]  Xuehong Lu,et al.  A statistical experimental study of the injection molding of optical lenses , 2001 .

[5]  Matthew D. Chidley,et al.  Design, assembly, and optical bench testing of a high-numerical-aperture miniature injection-molded objective for fiber-optic confocal reflectance microscopy. , 2006, Applied optics.

[6]  Jan Peirs,et al.  A micro optical force sensor for force feedback during minimally invasive robotic surgery , 2003 .

[7]  G. Gelikonov,et al.  In vivo endoscopic OCT imaging of precancer and cancer states of human mucosa. , 1997, Optics express.

[8]  C. Alvarado,et al.  Nosocomial infections from contaminated endoscopes: a flawed automated endoscope washer. An investigation using molecular epidemiology. , 1991, The American journal of medicine.

[9]  Sang June Yoon,et al.  Combined two-photon microscopy and optical coherence tomography using individually optimized sources. , 2011, Optics express.

[10]  G. Fedder,et al.  Endoscopic optical coherence tomography based on a microelectromechanical mirror. , 2001, Optics letters.

[11]  A. Okamura Haptic feedback in robot-assisted minimally invasive surgery , 2009, Current opinion in urology.

[12]  Kuo-Ming Tsai,et al.  A study of the effects of process parameters for injection molding on surface quality of optical lenses , 2009 .

[13]  J. Fujimoto,et al.  In vivo endoscopic optical biopsy with optical coherence tomography. , 1997, Science.