Characteristic Analysis for Multisampled Digital Implementation of Fixed-Switching-Frequency Closed-Loop Modulation of Voltage-Source Inverter

In this paper, a fixed-switching-frequency closed-loop modulation of a voltage-source inverter (VSI), upon the digital implementation of the modulation process, is analyzed and characterized. The sampling frequency of the digital processor is considered as an integer multiple of the modulation switching frequency. An expression for the determination of the modulation design parameter is developed for smooth modulation at a fixed switching frequency. The variation of the sampling frequency, switching frequency, and modulation index has been analyzed for the determination of the switching condition under closed loop. It is shown that the switching condition determined based on the continuous-time analysis of the closed-loop modulation will ensure smooth modulation upon the digital implementation of the modulation process. However, the stability properties need to be tested prior to digital implementation as they get deteriorated at smaller sampling frequencies. The closed-loop modulation index needs to be considered maximum while determining the design parameters for smooth modulation. In particular, a detailed analysis has been carried out by varying the control gain in the sliding-mode control of a two-level VSI. The proposed analysis of the closed-loop modulation of the VSI has been verified for the operation of a distribution static compensator. The theoretical results are validated experimentally on both single- and three-phase systems.

[1]  Donald Grahame Holmes,et al.  Corrections to "Opportunities for harmonic cancellation with carrier-based PWM for two-level and multilevel cascaded inverters" , 2001 .

[2]  B. C. Kuo Forced oscillations and suppression of oscillations in nonlinear sampled-data systems , 1966 .

[3]  Francesc Guinjoan,et al.  A fixed-frequency quasi-sliding control algorithm: application to power inverters design by means of FPGA implementation , 2003 .

[4]  Hiroshi Kawakami,et al.  Bifurcation analysis of switched dynamical systems with periodically moving borders , 2004, IEEE Transactions on Circuits and Systems I: Regular Papers.

[5]  Zeliang Shu,et al.  Steady-State and Dynamic Study of Active Power Filter With Efficient FPGA-Based Control Algorithm , 2008, IEEE Transactions on Industrial Electronics.

[6]  Samir Kouro,et al.  Reduced Switching-Frequency-Modulation Algorithm for High-Power Multilevel Inverters , 2007, IEEE Transactions on Industrial Electronics.

[7]  Benjamin C. Kuo,et al.  Digital Control Systems , 1977 .

[8]  Geoffrey R. Walker,et al.  Digitally-implemented naturally sampled PWM suitable for multilevel converter control , 2003 .

[9]  P. Mattavelli,et al.  Fully digital hysteresis modulation with switching time prediction , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[10]  Francesc Guinjoan,et al.  Interleaving Quasi-Sliding-Mode Control of Parallel-Connected Buck-Based Inverters , 2008, IEEE Transactions on Industrial Electronics.

[11]  F. D. Tan,et al.  A unified model for current-programmed converters , 1995 .

[12]  Marian P. Kazmierkowski,et al.  Current control techniques for three-phase voltage-source PWM converters: a survey , 1998, IEEE Trans. Ind. Electron..

[13]  Aman Behal,et al.  Experimental Comparison of Digital Implementations of Single-Phase PFC Controllers , 2008, IEEE Transactions on Industrial Electronics.

[14]  C. K. Michael Tse,et al.  General Design Issues of Sliding-Mode Controllers in DC–DC Converters , 2008, IEEE Transactions on Industrial Electronics.

[15]  Arthur Gelb,et al.  Multiple-Input Describing Functions and Nonlinear System Design , 1968 .

[16]  Mariusz Malinowski,et al.  Comparison of 2.3-kV Medium-Voltage Multilevel Converters for Industrial Medium-Voltage Drives , 2007, IEEE Transactions on Industrial Electronics.

[17]  Arindam Ghosh,et al.  Switching Characterization of Cascaded Multilevel-Inverter-Controlled Systems , 2008, IEEE Transactions on Industrial Electronics.

[18]  A. Joshi,et al.  Application of Immune-Based Optimization Method for Fault-Section Estimation in a Distribution System , 2002, IEEE Power Engineering Review.

[19]  Johann W. Kolar,et al.  Comparison of Prediction Techniques to Compensate Time Delays Caused by Digital Control of a Three-Phase Buck-Type PWM Rectifier System , 2008, IEEE Transactions on Industrial Electronics.

[20]  F. S. Merwe,et al.  Voltage harmonics generated by voltage-fed inverters using PWM natural sampling , 1988 .

[21]  Paolo Mattavelli,et al.  High-Bandwidth Multisampled Digitally Controlled DC–DC Converters Using Ripple Compensation , 2008, IEEE Transactions on Industrial Electronics.

[22]  Arindam Ghosh,et al.  A flexible DSTATCOM operating in voltage or current control mode , 2002 .

[23]  Arindam Ghosh,et al.  Frequency-domain characterization of sliding mode control of an inverter used in DSTATCOM application , 2006, IEEE Transactions on Circuits and Systems I: Regular Papers.

[24]  Nicolas Patin,et al.  FPGA-Based Current Controllers for AC Machine Drives—A Review , 2007, IEEE Transactions on Industrial Electronics.

[25]  Holmes,et al.  Pulse width modulation for power converters , 2003 .