A MEMS-based valveless impedance pump utilizing electromagnetic actuation

This study presents a planar valveless impedance-based micro pump for biomedical applications. The micro pump comprises four major components, namely a lower glass substrate containing a copper micro coil, a microchannel, an upper glass cover plate and a PDMS diaphragm with a magnet mounted on its upper surface. When a current is passed through the micro coil, an electromagnetic force is established between the coil and the magnet. The resulting deflection of the PDMS diaphragm creates an acoustic impedance mismatch within the microchannel, which results in a net flow. The performance of the micro pump is characterized both experimentally and numerically using Ansoft/Maxwell3D FEA software. The results show that the mechanical integrity of the micro pump is assured provided that the diaphragm deflection does not exceed 110 µm. This deflection is obtained by supplying the micro coil with an input current of 0.6 A, and results in a flow rate of 7.2 ml min−1 when the PDMS membrane is driven by an actuating frequency of 200 Hz.

[1]  M. Capanu,et al.  Design, fabrication, and testing of a bistable electromagnetically actuated microvalve , 2000, Journal of Microelectromechanical Systems.

[2]  C. Ahn,et al.  A bidirectional magnetic microactuator using electroplated permanent magnet arrays , 2002 .

[3]  E. Makino,et al.  Fabrication of TiNi shape memory micropump , 2001 .

[4]  Hsien-Tsung Chang,et al.  Theoretical analysis and optimization of electromagnetic actuation in a valveless microimpedance pump , 2007, Microelectron. J..

[5]  Bruce C. Towe,et al.  A thermopneumatic dispensing micropump , 2004 .

[6]  S. Timoshenko,et al.  THEORY OF PLATES AND SHELLS , 1959 .

[7]  Alan G. R. Evans,et al.  Investigation for the operation of an integrated peristaltic micropump , 2004 .

[8]  Kyihwan Park,et al.  Feasibility test of an electromagnetically driven valve actuator for glaucoma treatment , 2002 .

[9]  Linda G. Griffith,et al.  Design, modeling and fabrication of a constant flow pneumatic micropump , 2007 .

[10]  Göran Stemme,et al.  A valve-less planar fluid pump with two pump chambers , 1995 .

[11]  Tatsuya Fukami,et al.  Silicon micro optical switching device with an electromagnetically operated cantilever , 2000 .

[12]  M. C. Tracey,et al.  Dual independent displacement-amplified micropumps with a single actuator , 2006 .

[13]  Martin A. M. Gijs,et al.  Glass valveless micropump using electromagnetic actuation , 2005 .

[14]  H. F. Bauer,et al.  Axisymmetric oscillation of a viscous liquid covered by an elastic structure , 2005 .

[15]  M. Richter,et al.  A bidirectional silicon micropump , 1995 .

[16]  L. K. Lagorce,et al.  Magnetic microactuators based on polymer magnets , 1999 .

[17]  Jack W. Judy,et al.  Magnetic microactuation of torsional polysilicon structures , 1996 .

[18]  Peter Enoksson,et al.  A Valve-Less Diffuser Micropump for Microfluidic Analytical Systems , 2001 .

[19]  John A Rogers,et al.  A photocurable poly(dimethylsiloxane) chemistry designed for soft lithographic molding and printing in the nanometer regime. , 2003, Journal of the American Chemical Society.

[20]  Mir Majid Teymoori,et al.  Design and simulation of a novel electrostatic peristaltic micromachined pump for drug delivery applications , 2005 .

[21]  G. Kovacs Micromachined Transducers Sourcebook , 1998 .

[22]  Zhaoying Zhou,et al.  Design, optimization and simulation on microelectromagnetic pump , 2000 .

[23]  Jordan M. Berg,et al.  A two-stage discrete peristaltic micropump , 2003 .

[24]  Hsien-Tsung Chang,et al.  Design and modeling of electromagnetic actuator in mems-based valveless impedance pump , 2007 .

[25]  Anna I Hickerson,et al.  A valveless micro impedance pump driven by electromagnetic actuation , 2005 .

[26]  Jörg Müller,et al.  Numerical simulation and optimization of planar electromagnetic actuators , 1998 .

[27]  Peter Enoksson,et al.  A valve-less planar pump isotropically etched in silicon , 1996 .

[28]  C. Schabmueller,et al.  Self-aligning gas/liquid micropump , 2002 .

[29]  Wolfgang Benecke,et al.  Electromagnetically driven microvalve fabricated in silicon , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).

[30]  P. Bergveld,et al.  A plastic micropump constructed with conventional techniques and materials , 1999 .

[31]  Jaesung Jang,et al.  Theoretical and experimental study of MHD (magnetohydrodynamic) micropump , 2000 .

[32]  T. Bourouina,et al.  Design and simulation of an electrostatic micropump for drug-delivery applications , 1997 .

[33]  P. Dario,et al.  A piezoelectric-driven stereolithography-fabricated micropump , 1995 .

[34]  James S. Wilkinson,et al.  Design and theoretical evaluation of a novel microfluidic device to be used for PCR , 2003 .

[35]  Wai-Fah Chen,et al.  Plasticity for Structural Engineers , 1988 .

[36]  G. Stemme,et al.  Micromachined flat-walled valveless diffuser pumps , 1997 .

[37]  Li Wang,et al.  Characteristics and fabrication of NiTi/Si diaphragm micropump , 2001 .

[38]  Hermann Wätzig,et al.  Control of the electroosmotic flow by metal-salt-containing buffers , 1995 .

[39]  G. Fedder,et al.  Micro-electro-mechanical systems (MEMS)-based micro-scale direct methanol fuel cell development , 2006 .

[40]  Xiaoning Jiang,et al.  Micronozzle/diffuser flow and its application in micro valveless pumps , 1998 .

[41]  M. Allen,et al.  Integrated electroplated micromachined magnetic devices using low temperature fabrication processes , 2000 .

[42]  Bruce K. Gale,et al.  A PDMS-based gas permeation pump for on-chip fluid handling in microfluidic devices , 2006 .

[43]  Manuel Carmona,et al.  Design of a modular micropump based on anodic bonding , 1997 .

[44]  I. Zana,et al.  Co-Pt micromagnets by electrodeposition , 2002 .

[45]  Chih-Yung Wen,et al.  A Valveless Micro Impedance Pump Driven by PZT Actuation , 2006 .