Performance Analysis of a Wind-Catcher With Water Spray

Wind-catchers have been serving as a cooling system for providing acceptable natural ventilation using the renewable energy of wind. The effects of wind velocity and mass flow rate of water spray are investigated regarding the relative humidity and temperature of a wind-catcher in a hot and dry climate. Water spray increases the relative humidity and decreases the air temperature inside the wind-catcher. With an increase in the mass flow rate of water spray, the average relative humidity and temperature of indoor-space increase and decrease, respectively. Low wind speed with the same water spray mass flow rate provides a more pleasant air condition in comparison with that of the high wind speed. Adding water spray systems to wind-catchers contribute to pleasant air condition in hot and arid regions.

[1]  B. J. Vickery,et al.  Evaluation of pressure coefficients and estimation of air flow rates in buildings employing wind towers , 1986 .

[2]  Mohsen Mazidi,et al.  Experimental investigation of new designs of wind towers , 2008 .

[3]  Mohamed B. Gadi,et al.  Using CFD to Investigate Ventilation Characteristics of Domes as Wind-Inducing Devices in Buildings , 2007 .

[4]  Mehdi N. Bahadori,et al.  An improved design of wind towers for natural ventilation and passive cooling , 1985 .

[5]  Bin Liu,et al.  Energy Saving in Building Construction in China: A Review , 2004 .

[6]  Dr. Abdel-moniem El-Shorbagy Traditional Islamic-Arab House : Vocabulary And Syntax , 2013 .

[7]  S. A. Morsi,et al.  An investigation of particle trajectories in two-phase flow systems , 1972, Journal of Fluid Mechanics.

[8]  Vali Kalantar,et al.  Numerical simulation of cooling performance of wind tower (Baud-Geer) in hot and arid region , 2009 .

[9]  Ben Richard Hughes,et al.  A study of wind and buoyancy driven flows through commercial wind towers , 2011 .

[10]  Cheuk Ming Mak,et al.  Numerical evaluation of louver configuration and ventilation strategies for the windcatcher system , 2011 .

[11]  Abdel-moniem El-Shorbagy,et al.  Design with Nature: Windcatcher as a Paradigm of Natural Ventilation Device in Buildings , 2010 .

[12]  H Hamid Montazeri,et al.  Experimental and numerical study on natural ventilation performance of various multi-opening wind catchers , 2011 .

[13]  H Hamid Montazeri,et al.  Experimental study on natural ventilation performance of one-sided wind catcher , 2008 .

[14]  Hamid Saffari,et al.  Two-phase Euler-Lagrange CFD simulation of evaporative cooling in a Wind Tower , 2009 .

[15]  G. S. Battle,et al.  Wind Towers and Wind Driven Ventilation , 2000 .

[16]  Cheuk Ming Mak,et al.  The assessment of the performance of a windcatcher system using computational fluid dynamics , 2007 .

[17]  W. Ranz Evaporation from drops : Part II , 1952 .

[18]  V. S. Majali,et al.  Solar Thermal Modeling of Non-Air-Conditioned Multi-Zone Building: Evaluation of Heat Fluxes and Room Air Temperatures , 2008 .

[19]  Yuehong Su,et al.  Experimental and CFD study of ventilation flow rate of a Monodraught™ windcatcher , 2008 .

[20]  Abbas Elmualim,et al.  Dynamic modelling of a wind catcher/tower turret for natural ventilation , 2006 .

[21]  Abbas Elmualim,et al.  Effect of damper and heat source on wind catcher natural ventilation performance , 2006 .

[22]  H. Fathy,et al.  Natural energy and vernacular architecture : principles and examples with reference to hot arid climates , 1986 .

[23]  V. Costa,et al.  Use of Phase-Change Materials as Passive Elements for Climatization Purposes in Summer: The Portuguese Case , 2009 .

[24]  G. Gong,et al.  Research on the Air Stability of Limited Space , 2010 .

[25]  H Hamid Montazeri,et al.  Two-sided wind catcher performance evaluation using experimental, numerical and analytical modeling , 2010 .

[26]  W. E. Ranz,et al.  Evaporation from drops , 1952 .