Rapid ELISA Using a Film-Stack Reaction Field with Micropillar Arrays

A film-stack reaction field with a micropillar array using a motor stirrer was developed for the high sensitivity and rapid enzyme-linked immunosorbent assay (ELISA) reaction. The effects of the incubation time of a protein (30 s, 5 min, and 10 min) on the fluorescence intensity in ELISAs were investigated using a reaction field with different micropillar array dimensions (5-µm, 10-µm and 50-µm gaps between the micropillars). The difference in fluorescence intensity between the well with the reaction field of 50-µm gap for the incubation time of 30 s and the well without the reaction field with for incubation time of 10 min was 6%. The trend of the fluorescence intensity in the gap between the micro pillars in the film-stack reaction field was different between the short incubation time and the long incubation time. The theoretical analysis of the physical parameters related with the biomolecule transport indicated that the reaction efficiency defined in this study was the dominant factor determining the fluorescence intensity for the short incubation time, whereas the volumetric rate of the circulating flow through the space between films and the specific surface area were the dominant factors for the long incubation time.

[1]  Yanyi Huang,et al.  High-throughput immunoassay through in-channel microfluidic patterning. , 2012, Lab on a chip.

[2]  K. Uchiyama,et al.  Preparation of Two-dimensionally Ordered Microbeads Structure Dispensed with an Ink-jet and Its Application to ELISA , 2009, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[3]  A. Manz,et al.  Miniaturized total chemical analysis systems: A novel concept for chemical sensing , 1990 .

[4]  J. Beck,et al.  Enzyme immunoassays with special reference to ELISA techniques. , 1978, Journal of clinical pathology.

[5]  R. Lequin Enzyme immunoassay (EIA)/enzyme-linked immunosorbent assay (ELISA). , 2005, Clinical chemistry.

[6]  M. Shimojima,et al.  High sensitivity, high surface area Enzyme-linked Immunosorbent Assay (ELISA). , 2015, Bio-medical materials and engineering.

[7]  Mina Hoorfar,et al.  Numerical modeling of mass transport in microfluidic biomolecule-capturing devices equipped with reactive surfaces , 2010 .

[8]  A. Rasooly,et al.  ELISA-LOC: lab-on-a-chip for enzyme-linked immunodetection. , 2010, Lab on a chip.

[9]  Tetsuhide Shimizu,et al.  Fabrication and evaluation of micro-structured reaction field with vertically aligned carbon nanotubes for micro bio-analysis device , 2016 .

[10]  L. G. Mendoza,et al.  High-throughput microarray-based enzyme-linked immunosorbent assay (ELISA). , 1999, BioTechniques.

[11]  M. Schmidt,et al.  Microfabrication in biology and medicine. , 1999, Annual review of biomedical engineering.

[12]  K. Uchiyama,et al.  Influence of structural dimensions of micro-pillar array in reaction field on sensitivity of enzyme-linked immunosorbent assay (ELISA) , 2018 .

[13]  Pieter Telleman,et al.  Microsystem Engineering of Lab-on-a-chip devices. , 2003 .

[14]  Jianmin Yang,et al.  A Compact Immunoassay Platform Based on a Multicapillary Glass Plate , 2014, Sensors.

[15]  E. Engvall,et al.  ELISA (Enzyme‐Linked Immunosorbent Assay) , 2002 .

[16]  Y. K. Cheung,et al.  1 Supplementary Information for : Microfluidics-based diagnostics of infectious diseases in the developing world , 2011 .

[17]  J. Butler Enzyme-Linked Immunosorbent Assay , 2000, Journal of immunoassay.