Correction of parallel transmission using concurrent RF and gradient field monitoring

ObjectivesThe accuracy and precision of the parallel RF excitations are highly dependent on the spatial and temporal fidelity of the magnetic fields involved in spin excitation. The consistency between the nominal and effective fields is typically limited by the imperfections of the employed hardware existing both in the gradient system and the RF chain. In this work, we experimentally presented highly improved spatially tailored parallel excitations by turning the native hardware accuracy challenge into a measurement and control problem using an advanced field camera technology to fully correct parallel RF transmission experiment.Materials and methodsAn array of NMR field probes is used to measure the multiple channel RF pulses and gradient waveforms recording the high power RF pulses simultaneously with low frequency gradient fields on equal time basis. The recorded waveforms were integrated in RF pulse design for gradient trajectory correction, time imperfection compensation and introduction of iterative RF pre-emphasis.ResultsSuperior excitation accuracy was achieved. Two major applications were presented at 7 Tesla including multi-dimensional tailored RF pulses for spatially selective excitation and slice-selective spoke pulses for $$B_{1}^{ + }$$B1+ mitigation.ConclusionComprehensive field monitoring is a highly effective means of correcting for the field deviations during parallel transmit pulse design.

[1]  J. Pauly,et al.  Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging]. , 1991, IEEE transactions on medical imaging.

[2]  K. Pruessmann,et al.  Spatiotemporal magnetic field monitoring for MR , 2008, Magnetic resonance in medicine.

[3]  William A Grissom,et al.  Small‐tip‐angle spokes pulse design using interleaved greedy and local optimization methods , 2012, Magnetic resonance in medicine.

[4]  Peter Börnert,et al.  On spatially selective RF excitation and its analogy with spiral MR image acquisition , 1998, Magnetic Resonance Materials in Physics, Biology and Medicine.

[5]  Greig C. Scott,et al.  Frequency-Offset Cartesian Feedback for MRI Power Amplifier Linearization , 2011, IEEE Transactions on Medical Imaging.

[6]  D. I. Hoult,et al.  Overcoming high-field RF problems with non-magnetic Cartesian feedback transceivers , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[7]  P. Börnert,et al.  Transmit SENSE , 2003, Magnetic resonance in medicine.

[8]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[9]  Benedikt A. Poser,et al.  Estimating and eliminating the excitation errors in bipolar gradient composite excitations caused by radiofrequency‐gradient delay: Example of bipolar spokes pulses in parallel transmission , 2016, Magnetic resonance in medicine.

[10]  Simon Gross,et al.  Concurrent recording of RF pulses and gradient fields – comprehensive field monitoring for MRI , 2016, NMR in biomedicine.

[11]  P. Jezzard,et al.  Calibration of gradient propagation delays for accurate two‐dimensional radiofrequency pulses , 2005, Magnetic Resonance in Medicine.

[12]  J. Hennig,et al.  Robust spatially selective excitation using radiofrequency pulses adapted to the effective spatially encoding magnetic fields , 2011, Magnetic resonance in medicine.

[13]  Klaas P Pruessmann,et al.  A transmit/receive system for magnetic field monitoring of in vivo MRI , 2009, Magnetic resonance in medicine.

[14]  William A. Grissom,et al.  Iterative Method for Predistortion of MRI Gradient Waveforms , 2014, IEEE Transactions on Medical Imaging.

[15]  Johnpauly A k-Space Analysis of Small-Tip-Angle Excitation , 2012 .

[16]  Vasily L Yarnykh,et al.  Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency field , 2007, Magnetic resonance in medicine.

[17]  Anthonie Hendrik Bergman,et al.  Optimization of eddy-current compensation☆ , 1990 .

[18]  Adam B Kerr,et al.  Minimum envelope roughness pulse design for reduced amplifier distortion in parallel excitation , 2010, Magnetic resonance in medicine.

[19]  Lars Kasper,et al.  Gradient system characterization by impulse response measurements with a dynamic field camera , 2013, Magnetic resonance in medicine.

[20]  C. Boesch,et al.  Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: Optimization of corrections and quantitative characterization of magnet/gradient systems , 1991, Magnetic resonance in medicine.

[21]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[22]  Douglas C Noll,et al.  Joint design of trajectory and RF pulses for parallel excitation , 2007, Magnetic resonance in medicine.

[23]  Peter Börnert,et al.  Improvements in spiral MR imaging , 1999, Magnetic Resonance Materials in Physics, Biology and Medicine.

[24]  Yudong Zhu,et al.  Parallel excitation with an array of transmit coils , 2004, Magnetic resonance in medicine.

[25]  Dardo Tomasi,et al.  Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging , 2005, Magnetic resonance in medicine.

[26]  J. M. Pauly,et al.  Vector Iterative Pre-Distortion : An Auto-calibration Method for Transmit Arrays , 2008 .

[27]  Xiaoping Wu,et al.  Parallel excitation in the human brain at 9.4 T counteracting k‐space errors with RF pulse design , 2010, Magnetic resonance in medicine.

[28]  I J Lowe,et al.  A novel eddy current compensation scheme for pulsed gradient systems , 1994, Magnetic resonance in medicine.

[29]  Zhi-Pei Liang,et al.  Joint design of spoke trajectories and RF pulses for parallel excitation , 2011, Magnetic resonance in medicine.

[30]  Douglas C Noll,et al.  Iterative RF pulse design for multidimensional, small‐tip‐angle selective excitation , 2005, Magnetic resonance in medicine.

[31]  C K Mechefske,et al.  Gradient‐induced acoustic and magnetic field fluctuations in a 4T whole‐body MR imager , 2000, Magnetic resonance in medicine.

[32]  Vivek K. Goyal,et al.  Sparsity-Enforced Slice-Selective MRI RF Excitation Pulse Design , 2008, IEEE Transactions on Medical Imaging.

[33]  K. Pruessmann,et al.  B  1+ interferometry for the calibration of RF transmitter arrays , 2009, Magnetic resonance in medicine.

[34]  Xiaojing Huang,et al.  Phase-Shifted Interpolation for Complex Signals , 2012, IEEE Communications Letters.

[35]  P. Jehenson,et al.  Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradients in NMR systems , 1990 .

[36]  Jurek A Nordmeyer-Massner,et al.  NMR probes for measuring magnetic fields and field dynamics in MR systems , 2008, Magnetic resonance in medicine.

[37]  Kawin Setsompop,et al.  Slice‐selective RF pulses for in vivo B  1+ inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16‐element coil , 2008, Magnetic resonance in medicine.

[38]  P Börnert,et al.  Effects of gradient anisotropy in MRI , 1998, Magnetic resonance in medicine.

[39]  Douglas C Noll,et al.  Spatial domain method for the design of RF pulses in multicoil parallel excitation , 2006, Magnetic resonance in medicine.

[40]  Alexis Amadon,et al.  New method to characterize and correct with sub‐µs precision gradient delays in bipolar multispoke RF pulses , 2017, Magnetic resonance in medicine.

[41]  A Macovski,et al.  Effects of RF amplifier distortion on selective excitation and their correction by prewarping , 1992, Magnetic resonance in medicine.

[42]  Steven M. Wright,et al.  Iterative RF pulse refinement for magnetic resonance imaging , 2002, IEEE Transactions on Biomedical Engineering.

[43]  D. G. Hughes,et al.  Quantitative characterization of the eddy current fields in a 40‐cm bore superconducting magnet , 1994, Magnetic resonance in medicine.

[44]  Shaihan J. Malik,et al.  Slice profile correction for transmit sensitivity mapping using actual flip angle imaging , 2011, Magnetic resonance in medicine.