Preliminary Evaluation of a Combined MicroPET®-MR System

There are many motivations for adding simultaneously acquired MR images to PET scanning. The most straight forward are, superior registration of MR and PET images, the addition of morphological detail when there is non-rigid motion and for pre-clinical studies simultaneous imaging could lead to a significant reduction in the time that animals are required to be anesthetised. In addition simultaneous MR has the potential to provide accurate motion correction for PET image reconstruction. For functional imaging simultaneous acquisition is required to assess the subject in the same physiological state, such as acute stroke studies. The elimination of the additional radiation associated with combining CT with PET, by providing anatomic detail with MR, would be a crucial advantage for cancer screening. Combining the two instruments necessitates some engineering tradeoffs, especially associated with the use of the highly developed photomultiplier tube (PMT) used for light amplification, because of its incompatibility with strong magnetic fields. Our approach is to provide a split in the magnet and gradients to locate the magnetic sensitive components, the PMTs, in regions of low magnetic field, leaving only the essential PET components, the scintillator blocks, in the strong magnetic field region. The crystals are coupled to the PMTs by extending the optical fibres. A further advantage accrues by moving the PET electronics out of the region seen by the MR radio-frequency (RF) and gradient coils as electromagnetic interference effects between the PET and MR systems, which could cause artefacts in either modality, are eliminated. Here we describe a preliminary evaluation of the system, which is essentially a microPET Focus-120 located in a 1T split magnet, and compare its performance to previous microPET instruments.

[1]  Bernd J. Pichler,et al.  Studies with a prototype high resolution PET scanner based on LSO-APD modules , 1997 .

[2]  Michel Defrise,et al.  Exact and approximate rebinning algorithms for 3-D PET data , 1997, IEEE Transactions on Medical Imaging.

[3]  Paul Kinahan,et al.  Analytic 3D image reconstruction using all detected events , 1989 .

[4]  Jeffrey T. Yap,et al.  Performance evaluation of the microPET-Focus - F120 , 2004 .

[5]  R Gruetter,et al.  Automatic, localized in Vivo adjustment of all first‐and second‐order shim coils , 1993, Magnetic resonance in medicine.

[6]  Paul Kinahan,et al.  Determining block detector positions for PET scanners , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[7]  R. C. Hawkes,et al.  Development of a Combined microPET®-MR System , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[8]  Roger Lecomte,et al.  Initial results from the Sherbrooke avalanche photodiode positron tomograph , 1996 .

[9]  G. Delso,et al.  PET/MRI system design , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[10]  Dale L. Bailey,et al.  A method for measuring the absolute sensitivity of positron emission tomographic scanners , 1991, European Journal of Nuclear Medicine.

[11]  Gerald Entine,et al.  Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes , 2006, Physics in medicine and biology.

[12]  Magdalena Rafecas,et al.  A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals , 2001, European Journal of Nuclear Medicine.

[13]  Richard Bowtell,et al.  Split gradient coils for simultaneous PET‐MRI , 2009, Magnetic resonance in medicine.

[14]  R. N. Goble,et al.  Performance evaluation of the microPET R4 PET scanner for rodents , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[15]  E. Hoffman,et al.  Measuring PET scanner sensitivity: relating countrates to image signal-to-noise ratios using noise equivalents counts , 1990 .

[16]  M. Daube-Witherspoon,et al.  Treatment of axial data in three-dimensional PET. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.