Optimal hemoglobin extinction coefficient data set for near-infrared spectroscopy.

Extinction coefficient (ε) is a critical parameter for quantification of oxy-, deoxy-, and total-hemoglobin concentrations (Δ[HbO2], Δ[Hb], Δ[tHb]) from optical measurements of Near-infrared spectroscopy (NIRS). There are several different ε data sets which were frequently used in NIRS quantification. A previous study reported that even a small variation in ε could cause a significant difference in hemodynamic measurements. Apparently the selection of an optimal ε data set is important for NIRS. We conducted oxygen-state-varied and blood-concentration-varied model experiments with 57 human blood samples to mimic tissue hemodynamic variations. Seven reported ε data sets were evaluated by comparisons between quantifications and assumed values. We found that the Moaveni et al (1970)' ε data set was the optimal one, the NIRS quantification varied significantly among different ε data sets and parameter Δ[tHb] was most sensitive to ε data sets selection.

[1]  B Chance,et al.  Study of an algorithm based on model experiments and diffusion theory for a portable tissue oximeter. , 1997, Journal of biomedical optics.

[2]  David A. Boas,et al.  Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters , 2003, NeuroImage.

[3]  E. Gratton,et al.  Frequency-domain multichannel optical detector for noninvasive tissue spectroscopy and oximetry , 1995 .

[4]  D. Delpy,et al.  Quantification in tissue near–infrared spectroscopy , 1997 .

[5]  W. Zijlstra,et al.  Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin. , 1991, Clinical chemistry.

[6]  M. Arango,et al.  Near-infrared spectroscopy as an index of brain and tissue oxygenation. , 2009, British journal of anaesthesia.

[7]  Hanli Liu,et al.  Extinction coefficients of hemoglobin for near-infrared spectroscopy of tissue , 2005, IEEE Engineering in Medicine and Biology Magazine.

[8]  Setsuo Takatani,et al.  Theoretical Analysis of Diffuse Reflectance from a Two-Layer Tissue Model , 1979, IEEE Transactions on Biomedical Engineering.

[9]  S. Colak,et al.  Clinical optical tomography and NIR spectroscopy for breast cancer detection , 1999 .

[10]  J. Kim,et al.  Variation of haemoglobin extinction coefficients can cause errors in the determination of haemoglobin concentration measured by near-infrared spectroscopy , 2007, Physics in medicine and biology.

[11]  F. Jöbsis Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. , 1977, Science.

[12]  Hiroki Sato,et al.  Practicality of Wavelength Selection to Improve Signal-to-noise Ratio in Near-infrared Spectroscopy , 2003 .

[13]  D. Delpy,et al.  Characterization of the near infrared absorption spectra of cytochrome aa3 and haemoglobin for the non-invasive monitoring of cerebral oxygenation. , 1988, Biochimica et biophysica acta.

[14]  Ting Li,et al.  Bedside Monitoring of Patients with Shock Using a Portable Spatially-resolved Near-infrared Spectroscopy References and Links Study on Shock Monitoring Using a Space-resolved Nirs, " Pibm 2014, Proc. Spie. in Press , 2022 .

[15]  B. Horecker THE ABSORPTION SPECTRA OF HEMOGLOBIN AND ITS DERIVATIVES IN THE VISIBLE AND NEAR INFRA-RED REGIONS , 1943 .