In vivo measurement of lead in bone using x-ray fluorescence.

The factors affecting the accuracy and minimum detectable concentration of in vivo tibia lead measurement are discussed, and it is demonstrated that the use of a 109Cd source in a backscatter geometry and using the 88 keV coherently scattered photon for normalisation optimizes both criteria. The measurement is shown to be independent of variations in source-sample distance, thickness of overlying tissue and tibia size and shape. Applying the same technique in vitro to samples of human tibia and metatarsals, it is shown that the results are not significantly different (p approximately equal to 0.9) from atomic absorption spectrometry results from another laboratory. The results of Monte Carlo dose distribution calculations are presented and compared with measurements using thermoluminescent dosemeters: the mean absorbed dose to a 20 cm leg section is less than 0.1 mGy (10 mrad) and the maximum absorbed skin dose is 0.45 mGy (45 mrad). For this dose the minimum detectable lead concentration is 10 micrograms g-1. Finally, the technique has been applied to groups of normals and occupationally exposed workers, and the means have been shown to be significantly different, namely 10 and 31 micrograms g-1 respectively. In the normal subjects tibia lead correlated strongly with age (r = 0.63, p less than 0.001).

[1]  Robert T. Brown,et al.  Differential cross sections for coherent photon scattering by elements Z = 2 through Z = 26 , 1975 .

[2]  J. H. Hubbell,et al.  Relativistic atomic form factors and photon coherent scattering cross sections , 1979 .

[3]  B. W. Thomas,et al.  In vivo X-ray fluorescence estimation of bone lead concentrations in Queensland adults. , 1984, The British journal of radiology.

[4]  A. Aufderheide,et al.  Lead in bone. I. Direct analysis for lead in milligram quantities of bone ash by graphite furnace atomic absorption spectroscopy. , 1981, American journal of clinical pathology.

[5]  S. Mattsson,et al.  An X-ray fluorescence technique for in vivo determination of lead concentration in a bone matrix. , 1979, Physics in medicine and biology.

[6]  D. Slatkin,et al.  Feasibility Study for the in Vivo Measurement of Lead in Bone Using L-X-Ray Fluorescence , 1981, IEEE Transactions on Nuclear Science.

[7]  D. Chettle,et al.  The factors affecting in vivo x-ray fluorescence measurements of lead in bone , 1982 .

[8]  P. R. Bevington,et al.  Data Reduction and Error Analysis for the Physical Sciences , 1969 .

[9]  P. Bloch,et al.  Measurement of lead content of children's teeth in situ by x-ray fluorescence. , 1977, Physics in medicine and biology.

[10]  H. Woodard,et al.  The elementary composition of human cortical bone. , 1962, Health physics.

[11]  E. Pfitzer,et al.  Lead in human tissues. , 1975, Toxicology and applied pharmacology.

[12]  P. Barry A comparison of concentrations of lead in human tissues. , 1975, British journal of industrial medicine.