Fast laboratory-based micro-computed tomography for pore-scale research: Illustrative experiments and perspectives on the future

Abstract Over the past decade, the wide-spread implementation of laboratory-based X-ray micro-computed tomography (micro-CT) scanners has revolutionized both the experimental and numerical research on pore-scale transport in geological materials. The availability of these scanners has opened up the possibility to image a rock's pore space in 3D almost routinely to many researchers. While challenges do persist in this field, we treat the next frontier in laboratory-based micro-CT scanning: in-situ, time-resolved imaging of dynamic processes. Extremely fast (even sub-second) micro-CT imaging has become possible at synchrotron facilities over the last few years, however, the restricted accessibility of synchrotrons limits the amount of experiments which can be performed. The much smaller X-ray flux in laboratory-based systems bounds the time resolution which can be attained at these facilities. Nevertheless, progress is being made to improve the quality of measurements performed on the sub-minute time scale. We illustrate this by presenting cutting-edge pore scale experiments visualizing two-phase flow and solute transport in real-time with a lab-based environmental micro-CT set-up. To outline the current state of this young field and its relevance to pore-scale transport research, we critically examine its current bottlenecks and their possible solutions, both on the hardware and the software level. Further developments in laboratory-based, time-resolved imaging could prove greatly beneficial to our understanding of transport behavior in geological materials and to the improvement of pore-scale modeling by providing valuable validation.

[1]  Stuart Crozier,et al.  Denoising of Dynamic Contrast-Enhanced MR Images Using Dynamic Nonlocal Means , 2010, IEEE Transactions on Medical Imaging.

[2]  V. Cnudde,et al.  A pore-scale study of fracture dynamics in rock using X-ray micro-CT under ambient freeze-thaw cycling. , 2015, Environmental science & technology.

[3]  Roberto Dinapoli,et al.  A new family of pixel detectors for high frame rate X-ray applications , 2010 .

[4]  Philip Coppens,et al.  An optical chopper for generation of short X-ray pulses to allow in-house time-resolved photocrystallography. Corrigendum , 2014 .

[5]  Pawel Grybos,et al.  High frame rate measurements of semiconductor pixel detector readout IC , 2012 .

[6]  O. Bunk,et al.  High-throughput ptychography using Eiger: scanning X-ray nano-imaging of extended regions. , 2014, Optics express.

[7]  G. Herman,et al.  Advances in discrete tomography and its applications , 2007 .

[8]  Gábor Székely,et al.  Estimation of affine transformations directly from tomographic projections in two and three dimensions , 2009, 2009 Proceedings of 6th International Symposium on Image and Signal Processing and Analysis.

[9]  Tim Salditt,et al.  Phase contrast tomography of the mouse cochlea at microfocus x-ray sources , 2013 .

[10]  Anders Kaestner,et al.  Imaging and image processing in porous media research , 2008 .

[11]  D. E. Moncton,et al.  Compact x-ray source based on burst-mode inverse Compton scattering at 100 kHz , 2014, 1409.6954.

[12]  Steffen Berg,et al.  Interfacial velocities and capillary pressure gradients during Haines jumps. , 2013, Physical review. E, Statistical, nonlinear, and soft matter physics.

[13]  A. C. Payatakes,et al.  Flow mechanisms, relative permeabilities, and coupling effects in steady-state two-phase flow through porous media. The case of strong wettability , 1999 .

[14]  Jan Flusser,et al.  Image registration methods: a survey , 2003, Image Vis. Comput..

[15]  Trond Varslot,et al.  IMAGE REGISTRATION: ENHANCING AND CALIBRATING X-RAY MICRO-CT IMAGING , 2008 .

[16]  Isabelle Bloch,et al.  Multiple hypothesis tracking in microscopy images , 2009, 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[17]  Nathalie Harder,et al.  A benchmark for comparison of cell tracking algorithms , 2014, Bioinform..

[18]  A. Kingston,et al.  Dynamic tomography with a priori information. , 2011, Applied optics.

[19]  Marco Stampanoni,et al.  Towards Ultra-Fast X-ray Tomographic Microscopy of Liquid Water in PEFC , 2011 .

[20]  Ayaz Mehmani,et al.  The effect of microporosity on transport properties in porous media , 2014 .

[21]  Christoph H. Arns,et al.  Techniques in helical scanning, dynamic imaging and image segmentation for improved quantitative analysis with X-ray micro-CT , 2014 .

[22]  Kees Joost Batenburg,et al.  Region-Based Iterative Reconstruction of Structurally Changing Objects in CT , 2014, IEEE Transactions on Image Processing.

[23]  Jan Carmeliet,et al.  Characterisation of pore structure by combining mercury porosimetry and micrography , 2001 .

[24]  Martin J. Blunt,et al.  Dynamic Pore-scale Imaging of Reactive Transport in Heterogeneous Carbonates at Reservoir Conditions , 2014 .

[25]  Matthieu N. Boone,et al.  Dynamics of microcrack propagation in hardwood during heat treatment investigated by synchrotron-based X-ray tomographic microscopy , 2013, Wood Science and Technology.

[26]  Holger Ott,et al.  Subsecond pore-scale displacement processes and relaxation dynamics in multiphase flow , 2014, Water resources research.

[27]  Peter K. Kitanidis,et al.  Experimental Investigation and Pore-Scale Modeling Interpretation of Compound-Specific Transverse Dispersion in Porous Media , 2012, Transport in Porous Media.

[28]  Roberto Dinapoli,et al.  PILATUS: A single photon counting pixel detector for X-ray applications , 2009 .

[29]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[30]  Hans Knutsson,et al.  True 4D Image Denoising on the GPU , 2011, Int. J. Biomed. Imaging.

[31]  Veerle Cnudde,et al.  Three-Dimensional Analysis of High-Resolution X-Ray Computed Tomography Data with Morpho+ , 2011, Microscopy and Microanalysis.

[32]  L Van Hoorebeke,et al.  EDART, a discrete algebraic reconstructing technique for experimental data obtained with high resolution computed tomography. , 2014, Journal of X-ray science and technology.

[33]  John C. Russ,et al.  The image processing handbook (3. ed.) , 1995 .

[34]  H M Hertz,et al.  Comparison of Two X-ray Phase-contrast Imaging Methods with a Microfocus Source References and Links , 2022 .

[35]  H M Hertz,et al.  X-ray phase-contrast CO2 angiography for sub-10 μm vessel imaging , 2012, Physics in medicine and biology.

[36]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[37]  Marco Stampanoni,et al.  Development of a laser-based heating system for in situ synchrotron-based X-ray tomographic microscopy , 2012, Journal of synchrotron radiation.

[38]  J. Hopmans,et al.  Pore‐scale measurements of solute breakthrough using microfocus X‐ray computed tomography , 2000 .

[39]  D. Wildenschild,et al.  X-ray imaging and analysis techniques for quantifying pore-scale structure and processes in subsurface porous medium systems , 2013 .

[40]  Christopher H. Pentland,et al.  CO2 REACTIVE TRANSPORT IN LIMESTONE: FLOW REGIMES, FLUID FLOW AND MECHANICAL ROCK PROPERTIES , 2013 .

[41]  Patrick Dupont,et al.  An iterative maximum-likelihood polychromatic algorithm for CT , 2001, IEEE Transactions on Medical Imaging.

[42]  Eric R. Fossum,et al.  A high-speed, 240-frames/s, 4.1-Mpixel CMOS sensor , 2003 .

[43]  M. Blunt,et al.  Pore-scale imaging and modelling , 2013 .

[44]  Philip Coppens,et al.  An optical chopper for generation of short X-ray pulses to allow in-house time-resolved photocrystallography , 2014 .

[45]  Veerle Cnudde,et al.  Monitoring of stainless-steel slag carbonation using X-ray computed microtomography. , 2014, Environmental science & technology.

[46]  Martin J. Blunt,et al.  Pore-scale imaging of trapped supercritical carbon dioxide in sandstones and carbonates , 2014 .

[47]  O Betz,et al.  On the possibilities of hard X-ray imaging with high spatio-temporal resolution using polychromatic synchrotron radiation. , 2010, Journal of X-ray science and technology.

[48]  M. Glas,et al.  Principles of Computerized Tomographic Imaging , 2000 .

[49]  Технология Springer Science+Business Media , 2013 .

[50]  Veerle Cnudde,et al.  Recent Micro-CT Scanner Developments at UGCT , 2014 .

[51]  M. Fourar,et al.  Non-Fickian Description of Tracer Transport Through Heterogeneous Porous Media , 2009 .

[52]  Holger Steeb,et al.  A low-cost X-ray-transparent experimental cell for synchrotron-based X-ray microtomography studies under geological reservoir conditions. , 2014, Journal of synchrotron radiation.

[53]  Daccord Chemical dissolution of a porous medium by a reactive fluid. , 1987, Physical review letters.

[54]  R. Ritchie,et al.  Real-time Quantitative Imaging of Failure Events in Materials under Load at Temperatures above 1,600 , 2012 .

[55]  William J. Godinez,et al.  Objective comparison of particle tracking methods , 2014, Nature Methods.

[56]  Kees Joost Batenburg,et al.  DART: A Practical Reconstruction Algorithm for Discrete Tomography , 2011, IEEE Transactions on Image Processing.

[57]  Guido Gerig,et al.  Spatio-temporal Image Analysis for Longitudinal and Time-Series Image Data , 2014, Lecture Notes in Computer Science.

[58]  Rita Graceffa,et al.  High-speed detector for time-resolved diffraction studies. , 2013, Journal of physics. Conference series.

[59]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[60]  Federica Marone,et al.  Following dynamic processes by X-ray tomographic microscopy with sub-second temporal resolution , 2011 .

[61]  Martin J. Blunt,et al.  Changes in Pore Structure and Connectivity Induced by CO2 Injection in Carbonates: A Combined Pore-Scale Approach , 2013 .

[62]  Anna Burvall,et al.  First application of liquid-metal-jet sources for small-animal imaging: high-resolution CT and phase-contrast tumor demarcation. , 2013, Medical physics.

[63]  Yoshito Otake,et al.  Volume-of-change cone-beam CT for image-guided surgery , 2012, Physics in medicine and biology.

[64]  Roberto Dinapoli,et al.  Eiger: a single-photon counting x-ray detector , 2014 .

[65]  Veerle Cnudde,et al.  High-resolution X-ray computed tomography in geosciences: A review of the current technology and applications , 2013 .

[66]  Max A. Viergever,et al.  Using the Fourth Dimension to Distinguish Between Structures for Anisotropic Diffusion Filtering in 4D CT Perfusion Scans , 2014, STIA.

[67]  Ali Q. Raeini,et al.  Predictions of non-Fickian solute transport in different classes of porous media using direct simulation on pore-scale images. , 2013, Physical review. E, Statistical, nonlinear, and soft matter physics.

[68]  Andrew Kingston,et al.  Ground-truth verification of dynamic x-ray micro-tomography images of fluid displacement , 2012, Optics & Photonics - Optical Engineering + Applications.

[69]  W. Ludwig,et al.  First laboratory X‐ray diffraction contrast tomography for grain mapping of polycrystals , 2013 .

[70]  Frieder Enzmann,et al.  Real-time 3D imaging of Haines jumps in porous media flow , 2013, Proceedings of the National Academy of Sciences.

[71]  S. Pizer,et al.  The Image Processing Handbook , 1994 .

[72]  A. Lent,et al.  Iterative reconstruction algorithms. , 1976, Computers in biology and medicine.

[73]  Mohammad Piri,et al.  Pore-scale modeling of dispersion in disordered porous media. , 2011, Journal of contaminant hydrology.

[74]  Manuel Dierick,et al.  A novel beam hardening correction method requiring no prior knowledge, incorporated in an iterative reconstruction algorithm , 2012 .

[75]  Bram van Ginneken,et al.  Noise filtering in thin-slice 4D cerebral CT perfusion scans , 2010, Medical Imaging.

[76]  Uwe Oelfke,et al.  Imaging properties of small-pixel spectroscopic x-ray detectors based on cadmium telluride sensors , 2012, Physics in medicine and biology.

[77]  A. Makurat,et al.  Core-flood experiment for transport of reactive fluids in rocks. , 2012, The Review of scientific instruments.

[78]  Mats Larsbo,et al.  Imaging and quantification of preferential solute transport in soil macropores , 2014 .

[79]  Stefano Coraluppi,et al.  Multi-Stage Multiple-Hypothesis Tracking , 2011, J. Adv. Inf. Fusion.

[80]  H M Hertz,et al.  A 24 keV liquid-metal-jet x-ray source for biomedical applications. , 2011, The Review of scientific instruments.

[81]  Frouke Hoogland Liquid redistribution behind a drainage front in porous media imaged by neutron radiography , 2013 .

[82]  B. Bay,et al.  Digital volume correlation: Three-dimensional strain mapping using X-ray tomography , 1999 .

[83]  Lucia Mancini,et al.  A four-dimensional X-ray tomographic microscopy study of bubble growth in basaltic foam , 2012, Nature Communications.

[84]  Dorthe Wildenschild,et al.  Effect of fluid topology on residual nonwetting phase trapping: Implications for geologic CO 2 sequestration , 2013 .

[85]  Richard Frayne,et al.  Robust dynamic susceptibility contrast MR perfusion using 4D nonlinear noise filters , 2007, Journal of magnetic resonance imaging : JMRI.

[86]  Veerle Cnudde,et al.  Multi-scale, micro-computed tomography-based pore network models to simulate drainage in heterogeneous rocks , 2015 .

[87]  Tommy Andersson,et al.  Liquid-metal-jet x-ray tube technology and tomography applications , 2014, Optics & Photonics - Optical Engineering + Applications.

[88]  P. Withers,et al.  Quantitative X-ray tomography , 2014 .

[89]  Martin J. Blunt,et al.  Residual CO2 imaged with X‐ray micro‐tomography , 2011 .

[90]  Andrew Kingston,et al.  DYNAMIC X-RAY MICRO-TOMOGRAPHY FOR REAL TIME IMAGING OF DRAINAGE AND IMBIBITION PROCESSES AT THE PORE SCALE , 2011 .

[91]  R. Ruth,et al.  X-ray phase-contrast tomography with a compact laser-driven synchrotron source , 2015, Proceedings of the National Academy of Sciences.

[92]  R. Armstrong,et al.  Critical capillary number: Desaturation studied with fast X‐ray computed microtomography , 2014 .