Wireless smart implants dedicated to multichannel monitoring and microstimulation

Innovative circuits and systems techniques are required to build advanced smart medical devices (SMD). The high reliability and very low power consumption are among the main criteria that must be given priority to implement in such implantable and wirelessly controlled microsystems. A typical device is composed of several integrated modules to be assembled on a thin substrate providing placement flexibility in the body. Monitoring of electrode-tissue interface condition is needed for enhanced safety, and for enabling troubleshooting after implantation. In order to improve controllability and observability, fully integrated binary phase-shift-keying (BPSK) demodulation combined with a passive modulation method allows full-duplex data high data rate communication between external controllers and implants. Case studies such as peripheral nerve interfaces to recuperate bladder functions, cortical multichannel stimulator, as well as cortical monitoring devices are reported.

[1]  Nigel H. Lovell,et al.  CMOS neurostimulation ASIC with 100 channels, scaleable output, and bidirectional radio-frequency telemetry , 2001, IEEE Transactions on Biomedical Engineering.

[2]  W. Ko,et al.  Design of radio-frequency powered coils for implant instruments , 1977, Medical and Biological Engineering and Computing.

[3]  S. Wong,et al.  Physical modeling of spiral inductors on silicon , 2000 .

[4]  L. Leija,et al.  ASIC-based batteryless implantable telemetry microsystem for recording purposes , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[5]  Gunnar Gudnason,et al.  CMOS CIRCUIT DESIGN FOR RF SENSORS , 2007 .

[6]  Dawn M. Taylor,et al.  Direct Cortical Control of 3D Neuroprosthetic Devices , 2002, Science.

[7]  C.M. Zierhofer,et al.  Geometric approach for coupling enhancement of magnetically coupled coils , 1996, IEEE Transactions on Biomedical Engineering.

[8]  Khalil Najafi,et al.  Towards a button-sized 1024-site wireless cortical microstimulating array , 2003 .

[9]  Qiuting Huang,et al.  A 0.5mW passive telemetry IC for biomedical applications , 1998, Proceedings of the 23rd European Solid-State Circuits Conference.

[10]  K.D. Wise Wireless implantable microsystems: coming breakthroughs in health care , 2002, 2002 Symposium on VLSI Circuits. Digest of Technical Papers (Cat. No.02CH37302).

[11]  Khalil Najafi,et al.  A high data transfer rate frequency shift keying demodulator chip for the wireless biomedical implants , 2002, The 2002 45th Midwest Symposium on Circuits and Systems, 2002. MWSCAS-2002..

[12]  Mohamad Sawan,et al.  Low-Power CMOS Interface for Recording and Processing Very Low Amplitude Signals , 2004 .

[13]  C. Wilson,et al.  Multiple site silicon-based probes for chronic recordings in freely moving rats: implantation, recording and histological verification , 2000, Journal of Neuroscience Methods.

[14]  M. Haugland,et al.  A Chip for an Implantable Neural Stimulator , 2000 .

[15]  Mohamad Sawan,et al.  Prosthetic Power Supplies , 1999 .

[16]  Colette Fabrigoule,et al.  Deep brain stimulation of the ventral caudate nucleus in the treatment of obsessive-compulsive disorder and major depression. Case report. , 2004, Journal of neurosurgery.

[17]  Mohamad Sawan,et al.  High power efficiency inductive link with full-duplex data communication , 2002, 9th International Conference on Electronics, Circuits and Systems.

[18]  M. Sawan Microsystems dedicated to wireless multichannel monitoring and microstimulation: design, test and packaging , 2004, Proceedings. 7th International Conference on Solid-State and Integrated Circuits Technology, 2004..

[19]  Kenneth W. Horch,et al.  Neuroprosthetics theory and practice , 2004 .

[20]  M. Sawan,et al.  New stimulation strategy to improve the bladder function in paraplegics: chronic experiments in dogs , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  Mohamad Sawan,et al.  Low-power implantable microsystem intended to multichannel cortical recording , 2004, 2004 IEEE International Symposium on Circuits and Systems (IEEE Cat. No.04CH37512).

[22]  Roland E. Best Phase-locked loops : design, simulation, and applications , 2003 .

[23]  C. Zierhofer,et al.  Electronic design of a cochlear implant for multichannel high-rate pulsatile stimulation strategies , 1995 .

[24]  P. H. Peckham,et al.  Data transmission from an implantable biotelemeter by load-shift keying using circuit configuration modulator , 1995 .

[25]  Mohamad Sawan,et al.  CMOS Front-end Amplifier Dedicated to Monitor Very Low Amplitude Signal from Implantable Sensors , 2000 .

[26]  Mohamad Sawan,et al.  A mixed-signal IC for multiple cortical stimulation strategies , 2002, The 2002 45th Midwest Symposium on Circuits and Systems, 2002. MWSCAS-2002..

[27]  Mohamad Sawan,et al.  A low-voltage 38/spl mu/W sigma-delta modulator dedicated to wireless signal recording applications , 2003, Proceedings of the 2003 International Symposium on Circuits and Systems, 2003. ISCAS '03..

[28]  C. Kufta,et al.  Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex. , 1996, Brain : a journal of neurology.

[29]  M. Sawan,et al.  Wireless Smart Implants Dedicated to Multichannel Monitoring and Microstimulation , 2005, The IEEE/ACS International Conference on Pervasive Services.

[30]  J.A. Cobos,et al.  Design issues of a core-less transformer for a contact-less application , 2002, APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335).

[31]  Tayfun Akin,et al.  A wireless implantable multichannel digital neural recording system for a micromachined sieve electrode , 1998, IEEE J. Solid State Circuits.

[32]  M. Sawan,et al.  Implantable measurement technique dedicated to the monitoring of electrode-nerve contact in bladder stimulators , 2006, Medical and Biological Engineering and Computing.

[33]  Yamu Hu,et al.  A 900 mV 25 /spl mu/W high PSRR CMOS voltage reference dedicated to implantable micro-devices , 2003, Proceedings of the 2003 International Symposium on Circuits and Systems, 2003. ISCAS '03..

[34]  M. Hull,et al.  A new technique for transmission of signals from implantable transducers , 1998, IEEE Transactions on Biomedical Engineering.

[35]  Kensall D. Wise,et al.  A 256-Site 3D CMOS Microelectrode Array for Multipoint Stimulation and Recording in the Central Nervous System , 2001 .

[36]  S. Pourmehdi,et al.  An externally powered, multichannel, implantable stimulator-telemeter for control of paralyzed muscle , 1998, IEEE Transactions on Biomedical Engineering.

[37]  Wentai Liu,et al.  An arbitrary waveform stimulus circuit for visual prostheses using a low-area multibias DAC , 2003, IEEE J. Solid State Circuits.

[38]  W. Liu,et al.  A neuro-stimulus chip with telemetry unit for retinal prosthetic device , 2000, IEEE Journal of Solid-State Circuits.

[39]  M. Sawan,et al.  CMOS front-end amplifier dedicated to monitor very low amplitude signal from implantable sensors , 2000, Proceedings of the 43rd IEEE Midwest Symposium on Circuits and Systems (Cat.No.CH37144).

[40]  B. Aouizerate,et al.  Deep brain stimulation of the ventral caudate nucleus in the treatment of obsessive—compulsive disorder and major depression , 2004 .

[41]  M. Elhilali,et al.  Implantable selective stimulator to improve bladder voiding: design and chronic experiments in dogs. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.