The ability of Kromoscopy to measure glucose selectively is demonstrated in solutions composed glucose, urea, triacetin, bovine serum albumin (BSA), cholesterol, and hemoglobin (Hb). Kromoscopic measurements are made with a four-channel instrument designed for measuring light between 1500 and 1900 nm. The channels are configured to respond to four individual bands of near infrared light centered at 1600, 1700, 1750, and 1800 nm. An equation is proposed that describes the relative response for each channel as a function of relevant experimental parameters. This equation predicts the linear response observed for these types of measurements as a function of solute concentration. In addition, molar absorptivities are provided for glucose, urea, triacetin, BSA, Hb, and water. The non-negligible absorptivity of water demands the consideration of water displacement caused by solute dissolution. Channel responses are measured for a series of thirty-one samples. The chemical composition of these samples is designed to minimize the correlations between glucose concentration and the concentrations of all other solutes. Likewise, these samples provide negligible correlation between the concentration of glucose and the extent of water displacement. A calibration model is constructed for glucose by using a conventional P-matrix multiple linear regression analysis of the four-channel information. The resulting model demonstrates selectivity for glucose with values of 1.27 and 1.34 mM for the standard errors of calibration and prediction, respectively, over a glucose concentration range of 1.9 to 19 mM.
[1]
M A Arnold,et al.
Evaluation of Kromoscopy: resolution of glucose and urea.
,
2000,
Applied optics.
[2]
H. Gremlich,et al.
Infrared and Raman Spectroscopy of Biological Materials
,
2000
.
[3]
L. Kou,et al.
Refractive indices of water and ice in the 0.65- to 2.5-µm spectral range.
,
1993,
Applied optics.
[4]
M J Block,et al.
Kromoscopic analysis: a possible alternative to spectroscopic analysis for noninvasive measurement of analytes in vivo.
,
1994,
Clinical chemistry.
[5]
Emil W. Ciurczak,et al.
Handbook of Near-Infrared Analysis
,
1992
.
[6]
Irving H. Malitson,et al.
Refraction and Dispersion of Synthetic Sapphire
,
1962
.
[7]
Airat K. Amerov,et al.
Kromoscopic analysis in two- and three-component aqueous solutions of blood constituents
,
2001,
SPIE BiOS.
[8]
P. Huibers.
Models for the wavelength dependence of the index of refraction of water.
,
1997,
Applied optics.
[9]
J. G. Bayly,et al.
The absorption spectra of liquid phase H2O, HDO and D2O from 0·7 μm to 10 μm
,
1963
.