Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD

Spinning-disc interferometry (SDI) is a high-speed laser scanning approach to surface metrology that uses common-path interferometry to measure protein spots on a BioCD disk. The measurement sensitivity depends on the scanning pitch and on the time-base. Based on high-resolution laser scanning images of printed antibody spots, we quantify the protein sensitivity as a function of the scan parameters. For smoothly printed antibody spots scanned with a transverse spatial resolution of 1 μm, the surface height precision for a single 100 μm diameter protein spot is approximately 1 pm. This detection sensitivity sets the fundamental limit of detection for label-free BioCD biosensors performing immunoassays.

[1]  M. Selim Ünlü,et al.  Label-free and dynamic detection of biomolecular interactions for high-throughput microarray applications , 2008, Proceedings of the National Academy of Sciences.

[2]  Ming Zhao,et al.  Prostate-specific antigen immunoassays on the BioCD , 2009, Analytical and bioanalytical chemistry.

[3]  Ming Zhao,et al.  Molecular interferometric imaging. , 2008, Optics express.

[4]  L. Bachas,et al.  Oriented immobilization of proteins , 1998 .

[5]  David D Nolte,et al.  Invited Review Article: Review of centrifugal microfluidic and bio-optical disks. , 2009, The Review of scientific instruments.

[6]  F. Regnier,et al.  Spinning-disk self-referencing interferometry of antigen-antibody recognition. , 2004, Optics letters.

[7]  Chang-Hee Lee,et al.  Oriented immobilization of antibodies by a self-assembled monolayer of 2-(biotinamido)ethanethiol for immunoarray preparation. , 2006, Colloids and surfaces. B, Biointerfaces.

[8]  Ming Zhao,et al.  Mass-transport limitations in spot-based microarrays , 2010, Biomedical optics express.

[9]  B. Polisky,et al.  Thin film biosensor for rapid visual detection of nucleic acid targets. , 1999, Clinical chemistry.

[10]  Guenter Gauglitz,et al.  Multiple reflectance interference spectroscopy measurements made in parallel for binding studies , 2005 .

[11]  B Guss,et al.  Chimeric IgG-binding receptors engineered from staphylococcal protein A and streptococcal protein G. , 1988, The Journal of biological chemistry.

[12]  Wang Xuefeng,et al.  Molecular Interferometric Imaging for Biosensor Applications , 2007, IEEE Journal of Selected Topics in Quantum Electronics.

[13]  Guenter Gauglitz,et al.  Direct optical sensors: principles and selected applications , 2005, Analytical and bioanalytical chemistry.

[14]  Leilei Peng,et al.  Adaptive interferometry of protein on a BioCD. , 2007, Applied optics.

[15]  D. Nolte,et al.  Ambient molecular water accumulation on silica surfaces detected by a reflectance interference optical balance. , 2010, Applied physics letters.

[16]  D. Nolte,et al.  Common-path interferometric detection of protein monolayer on the BioCD. , 2007, Applied optics.

[17]  Ming Zhao,et al.  Combined fluorescent and interferometric detection of protein on a BioCD. , 2008, Applied optics.

[18]  Ming Zhao,et al.  Differential phase-contrast BioCD biosensor. , 2007, Applied optics.

[19]  Yutaka Yamagata,et al.  Surface morphology and biological activity of protein thin films produced by electrospray deposition. , 2004, Journal of colloid and interface science.

[20]  D. Nolte Interferometric Thin-Film Optical Biosensors , 2012 .

[21]  R. Jenison,et al.  Interference-based detection of nucleic acid targets on optically coated silicon , 2001, Nature Biotechnology.

[22]  D. Nolte,et al.  Area-scaling of interferometric and fluorescent detection of protein on antibody microarrays. , 2008, Biosensors & bioelectronics.

[23]  Ming Zhao,et al.  High-speed interferometric detection of label-free immunoassays on the biological compact disc. , 2006, Clinical chemistry.

[24]  Ming Zhao,et al.  Prostate specific antigen detection in patient sera by fluorescence-free BioCD protein array. , 2011, Biosensors & bioelectronics.