Optimal focusing by spatio-temporal inverse filter. I. Basic principles.

A focusing technique based on the inversion of the propagation operator relating an array of transducers to a set of control points inside a medium was proposed in previous work [Tanter et al., J. Acoust. Soc. Am. 108, 223-234 (2000)] and is extended here to the time domain. As the inversion of the propagation operator is achieved both in space and time, this technique allows calculation of the set of temporal signals to be emitted by each element of the array in order to optimally focus on a chosen control point. This broadband inversion process takes advantage of the singular-value decomposition of the propagation operator in the Fourier domain. The physical meaning of this decomposition is explained in a homogeneous medium. In particular, a definition of the number of degrees of freedom necessary to define the acoustic field generated by an array of limited aperture in a focal plane of limited extent is given. This number corresponds to the number of independent signals that can be created in the focal area both in space and time. In this paper, this broadband inverse-focusing technique is compared in homogeneous media with the classical focusing achieved by simple geometrical considerations but also with time-reversal focusing. It is shown that, even in a simple medium, slight differences appear between these three focusing strategies. In the companion paper [Aubry et al., J. Acoust. Soc. Am. 110, 48-58 (2001)] the three focusing techniques are compared in heterogeneous, absorbing, or complex media where classical focusing is strongly degraded. The strong improvement achieved by the spatio-temporal inverse-filter technique emphasizes the great potential of multiple-channel systems having the ability to apply completely different signal waveforms on each transducer of the array. The application of this focusing technique could be of great interest in various ultrasonic fields such as medical imaging, nondestructive testing, and underwater acoustics.

[1]  M. Fink,et al.  The iterative time reversal mirror: A solution to self‐focusing in the pulse echo mode , 1991 .

[2]  J. Campbell,et al.  Effect of the skull in degrading the display of echoencephalographic B and C scans. , 1968, The Journal of the Acoustical Society of America.

[3]  V. Martin ACTIVE CONTROL OF MOVING SOUND SOURCE RADIATION—NUMERICAL MODELLING IN THE SPACE–FREQUENCY AND SPACE–TIME DOMAINS , 1999 .

[4]  Hareo Hamada,et al.  A MULTIPLE MICROPHONE RECORDING TECHNIQUE FOR THE GENERATION OF VIRTUAL ACOUSTIC IMAGES , 1999 .

[5]  Mathias Fink,et al.  Time Reversal Focusing Applied to Lithotripsy , 1996 .

[6]  C.A. Cain,et al.  Multiple-focus ultrasound phased-array pattern synthesis: optimal driving-signal distributions for hyperthermia , 1989, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  W. Kuperman,et al.  Iterative time reversal in the ocean , 1997 .

[8]  B. Steinberg,et al.  Wavefront amplitude distortion and image sidelobe levels. I. Theory and computer simulations , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  M. Fink,et al.  Time reversal of ultrasonic fields. I. Basic principles , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Mathias Fink,et al.  Eigenmodes of the time reversal operator: a solution to selective focusing in multiple-target media , 1994 .

[11]  Mathias Fink,et al.  Focusing in transmit–receive mode through inhomogeneous media: The time reversal matched filter approach , 1995 .

[12]  J L Thomas,et al.  Time reversal and the inverse filter. , 2000, The Journal of the Acoustical Society of America.

[13]  M. Fink Time reversed acoustics , 1997 .

[14]  P. VanBaren,et al.  Dynamic focusing in ultrasound hyperthermia treatments using implantable hydrophone arrays , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  R C Waag,et al.  Correction of ultrasonic wavefront distortion using backpropagation and a reference waveform method for time-shift compensation. , 1994, The Journal of the Acoustical Society of America.

[16]  Lin,et al.  Quantitative imaging using a time-domain eigenfunction method , 2000, The Journal of the Acoustical Society of America.

[17]  J L Thomas,et al.  Optimal focusing by spatio-temporal inverse filter. II. Experiments. Application to focusing through absorbing and reverberating media. , 2001, The Journal of the Acoustical Society of America.

[18]  M. O'Donnell,et al.  Phase Aberration Measurements in Medical Ultrasound: Human Studies , 1988 .

[19]  M. Fink,et al.  Time reversal of ultrasonic fields. Il. Experimental results , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  B.D. Steinberg,et al.  Wavefront amplitude distortion and image sidelobe levels. II. In vivo experiments , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.