A configurable IC to contol, readout, and calibrate an array of biosensors

We present a novel integrated circuit for a biosensing data acquisition chain. The circuit controls and reads out five bimolecular sensors as well as pH and temperature sensors for biosensor calibration. The IC supports both chronoamper-ometry (CA) and cyclic voltammetry (CV) measurements, which are commonly used in biosensing. Different voltage waveforms are generated to control CV by using a single configurable waveform generator and programmable constant voltage levels are produced to enable CA. To reduce the area and power consumption of the interface electronics, a unified circuit is designed for CV, CA and pH readout. The biosensors produce currents that are converted by a 13.5-bit sigma delta analog to digital converter. The circuit has been designed and realized in 0.18 μW technology. It consumes 711 μW from a 1.8 V supply voltage, making it suitable for remotely powered and implantable applications.

[1]  Giovanni De Micheli,et al.  Design, fabrication, and test of a sensor array for perspective biosensing in chronic pathologies , 2012, 2012 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[2]  Mo Zhang,et al.  Low-Power Low-Voltage Current Readout Circuit for Inductively Powered Implant System , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[3]  K.L. Shepard,et al.  Active CMOS Sensor Array for Electrochemical Biomolecular Detection , 2008, IEEE Journal of Solid-State Circuits.

[4]  Hitoshi Shiga,et al.  A CMOS band-gap reference circuit with sub 1 V operation , 1998, 1998 Symposium on VLSI Circuits. Digest of Technical Papers (Cat. No.98CH36215).

[5]  B.K. Ahuja,et al.  An improved frequency compensation technique for CMOS operational amplifiers , 1983, IEEE Journal of Solid-State Circuits.

[6]  Giovanni De Micheli,et al.  Fully Integrated Biochip Platforms for Advanced Healthcare , 2012, Sensors.

[7]  Giovanni De Micheli,et al.  An integrated platform for advanced diagnostics , 2011, 2011 Design, Automation & Test in Europe.

[8]  M. D. Rooij,et al.  Electrochemical Methods: Fundamentals and Applications , 2003 .

[9]  L. R. Carley,et al.  Analysis of switched-capacitor common-mode feedback circuit , 2003, IEEE Trans. Circuits Syst. II Express Briefs.

[10]  Graham A. Jullien,et al.  Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors , 2009, IEEE Transactions on Circuits and Systems I: Regular Papers.

[11]  Fred M. Hawkridge,et al.  The effects of temperature and electrolyte at acidic and alkaline pH on the electron transfer reactions of cytochrome c at In2O3 electrodes , 1988 .

[12]  Lin Li,et al.  CMOS Amperometric Instrumentation and Packaging for Biosensor Array Applications , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[13]  Yu-Te Liao,et al.  A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring , 2012, IEEE Journal of Solid-State Circuits.

[14]  Giovanni De Micheli,et al.  New Approaches for Carbon Nanotubes-Based Biosensors and Their Application to Cell Culture Monitoring , 2012, IEEE Transactions on Biomedical Circuits and Systems.

[15]  K. Sakui,et al.  A CMOS bandgap reference circuit with sub-1-V operation , 1999 .

[16]  Giovanni De Micheli,et al.  Nano-sensor and circuit design for anti-cancer drug detection , 2011, 2011 IEEE/NIH Life Science Systems and Applications Workshop (LiSSA).