A Study on Method for Identifying Capacity Factor Declination of Wind Turbines
暂无分享,去创建一个
Abstract—The investigation on wind turbine degradation was carried out using the nacelle wind data. The three Vestas V80-2MW wind turbines of Sungsan wind farm in Jeju Island, South Korea were selected for this work. The SCADA data of the wind farm for five years were analyzed to draw power curve of the turbines. It is assumed that the wind distribution is the Rayleigh distribution to calculate the normalized capacity factor based on the drawn power curve of the three wind turbines for each year. The result showed that the reduction of power output from the three wind turbines occurred every year and the normalized capacity factor decreased to 0.12%/year on average.
[1] Wilmar Hernandez,et al. Power Performance Verification of a Wind Farm Using the Friedman’s Test , 2016, Sensors.
[2] T. McCoy,et al. Applicability of Nacelle Anemometer Measurements for Use in Turbine Power Performance Tests: Preprint , 2002 .
[3] Hyeon-Wu Kim,et al. Wind Turbine Power Performance Testing using Nacelle Transfer Function , 2013 .