Improving accuracy of bone resections using robotics tool holder and a high speed milling cutting tool.

The use of non-cemented prosthetic components in implant surgery is demanding a high quality of bone beds in order to allow for a good level of osseointegration. Two parameters are significant in the evaluation of the quality of the host bone: roughness, which reports on the presence of gaps and peeks, and flatness, which reports on the total percentage of bone which lies in a given interval from the prosthesis. Robot assisted cutting of 32 pig femours and tibiae was performed using various techniques and options. This paper demonstrates roughness and flatness can be taken of the order of the limits necessary for osseointegration, by using a milling cutting tool mounted on a strong support, in this case a robot arm, improving on the results obtained by similar studies referred to hand sawed bones by 10 times.

[1]  Michael A. Peshkin,et al.  Total Knee Replacement , 1973, The Lancet.

[2]  S. Toksvig-Larsen,et al.  Improved bone cutting using a semirotating saw. A cadaver study of the cut surface on tibial condyles. , 1994, Acta orthopaedica Scandinavica.

[3]  S. Toksvig-Larsen,et al.  Surface characteristics following tibial preparation during total knee arthroplasty. , 1994, The Journal of arthroplasty.

[4]  L. Whiteside,et al.  Cutting errors in preparation of femoral components in total knee arthroplasty. , 1993, The Journal of arthroplasty.

[5]  L Ryd,et al.  Surface flatness after bone cutting. A cadaver study of tibial condyles. , 1991, Acta orthopaedica Scandinavica.

[6]  S. Stulberg,et al.  A new model to assess tibial fixation. II. Concurrent histologic and biomechanical observations. , 1991, Clinical orthopaedics and related research.

[7]  T. Albrektsson,et al.  Implant fixation improved by close fit. Cylindrical implant-bone interface studied in rabbits. , 1988, Acta orthopaedica Scandinavica.

[8]  S. Cook,et al.  Biological fixation of porous-coated implants. , 1987, The Journal of bone and joint surgery. American volume.

[9]  R. Ling Observations on the fixation of implants to the bony skeleton. , 1986, Clinical Orthopaedics and Related Research.

[10]  G. Holt,et al.  Osseointegrated Titanium Implants , 1986 .

[11]  J. Pugh,et al.  Surgery of the Hip-joint* , 1960, Springer New York.

[12]  H. Hansson,et al.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. , 1981, Acta orthopaedica Scandinavica.