Removal of EEG Noise and Artifact Using Blind Source Separation

Summary: A study was performed to investigate and compare the relative performance of blind signal separation (BSS) algorithms at separating common types of contamination from EEG. The study develops a novel framework for investigating and comparing the relative performance of BSS algorithms that incorporates a realistic EEG simulation with a known mixture of known signals and an objective performance metric. The key finding is that although BSS is an effective and powerful tool for separating and removing contamination from EEG, the quality of the separation is highly dependant on the type of contamination, the degree of contamination, and the choice of BSS algorithm. BSS appears to be most effective at separating muscle and blink contamination and less effective at saccadic and tracking contamination. For all types of contamination, principal components analysis is a strong performer when the contamination is greater in amplitude than the brain signal whereas other algorithms such as second-order blind inference and Infomax are generally better for specific types of contamination of lower amplitude.

[1]  P Berg,et al.  Dipole modelling of eye activity and its application to the removal of eye artefacts from the EEG and MEG. , 1991, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[2]  C. Joyce,et al.  Automatic removal of eye movement and blink artifacts from EEG data using blind component separation. , 2004, Psychophysiology.

[3]  T. Sejnowski,et al.  Removal of eye activity artifacts from visual event-related potentials in normal and clinical subjects , 2000, Clinical Neurophysiology.

[4]  G. Gratton Dealing with artifacts: The EOG contamination of the event-related brain potential , 1998 .

[5]  P. Berg,et al.  Dipole models of eye movements and blinks. , 1991, Electroencephalography and clinical neurophysiology.

[6]  Arnaud Delorme,et al.  EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis , 2004, Journal of Neuroscience Methods.

[7]  Patrick Berg,et al.  Artifact Correction of the Ongoing EEG Using Spatial Filters Based on Artifact and Brain Signal Topographies , 2002, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[8]  Tzyy-Ping Jung,et al.  Extended ICA Removes Artifacts from Electroencephalographic Recordings , 1997, NIPS.

[9]  Martin J. McKeown,et al.  Removing electroencephalographic artifacts: comparison between ICA and PCA , 1998, Neural Networks for Signal Processing VIII. Proceedings of the 1998 IEEE Signal Processing Society Workshop (Cat. No.98TH8378).

[10]  T. Lagerlund,et al.  Spatial filtering of multichannel electroencephalographic recordings through principal component analysis by singular value decomposition. , 1997, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[11]  R N Vigário,et al.  Extraction of ocular artefacts from EEG using independent component analysis. , 1997, Electroencephalography and clinical neurophysiology.