Evaluation of effective dose and entrance skin dose in digital radiology

Abstract Background: Ionizing radiation has an indispensable role in diagnostic radiology and clinical treatments. Apparently, medical exposure in diagnostic radiology pertains to be the preeminent man-made source of radiation. Objective: The aim of the present scientific study is to calculate the Entrance Surface Dose (ESD) and Effective Dose (ED) in digital radiography in Mazandaran province. Materials and methods: The study was performed on 3600 patients in digital X-ray rooms 15 hospitals and the required data were collected from two age groups (10>15 years and adults) in each projection. Based on the results of this study, ESD and ED were calculated for skull (PA), skull (lateral), cervical spine (AP), cervical spine (lateral), chest (PA), chest (lateral), abdomen (AP), lumbar spine (AP), lumbar spine (lateral), pelvis (AP), thoracic spine (AP) and thoracic spine (lateral) examinations. It was calculated using PCXMC software (version 2.0). Results: In this study, mean ESDs for the 10-15 year group varied from 0.97±0.21 mGy to 3.62±1.38 mGy for chest (PA) and lumbar spine (lateral), respectively. For the adult group varied from 1.05±0.31 to 3.85±1.44 for cervical spine (AP) and lumbar spine (lateral), respectively. And also ED value was from in the range of 10.40 µSv to 378.46 µSv for skull (PA) 10-15 year group and abdomen adults, respectively Conclusion: This survey revealed a significant variation in the radiation dose of digital radiology examinations among hospitals in Mazandaran province. Application of a dose reference level (DRL) could be an optimization procedure for reducing the patient’s dose in Mazandaran province.

[1]  Patient Dosimetry for X Rays Used in Medical Imaging , 2005 .

[2]  J. I. Ten,et al.  Transition from screen-film to digital radiography: evolution of patient radiation doses at projection radiography. , 2007, Radiology.

[3]  D. Brenner,et al.  Cancer risks from diagnostic radiology. , 2008, The British journal of radiology.

[4]  J. Darko,et al.  A Survey of Organ Equivalent and Effective Doses from Diagnostic Radiology Procedures , 2012, ISRN radiology.

[5]  V. Muse,et al.  What Patients Want to Know about Imaging Examinations: A Multiinstitutional U.S. Survey in Adult and Pediatric Teaching Hospitals on Patient Preferences for Receiving Information before Radiologic Examinations. , 2018, Radiology.

[6]  P. C. Shrimpton,et al.  Effective dose and risks from medical x-ray procedures , 2012, Annals of the ICRP.

[7]  N. Shams,et al.  Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD) , 2017 .

[8]  D. Košutić,et al.  First results on patient dose measurements from conventional diagnostic radiology procedures in Serbia and Montenegro. , 2005, Radiation protection dosimetry.

[9]  B. Mohsenzadeh,et al.  The National Diagnostic Reference Level in Routine Digital Radiography Examinations in Iran , 2018, Biomedical Journal of Scientific & Technical Research.

[10]  J. Alsuwaidi,et al.  Patient dose monitoring in Dubai in radiography and interventional procedures , 2015, Annals of the ICRP.

[11]  E. O. Darko,et al.  Estimation of adult patient doses for selected X-ray diagnostic examinations , 2014 .

[12]  M. Deevband,et al.  Local-Reference Patient Dose Evaluation in Conventional Radiography Examinations in Mazandaran, Iran , 2016, Journal of biomedical physics & engineering.

[13]  H. Nahangi,et al.  Assessment of radiation risk to pediatric patients undergoing conventional X-ray examinations , 2015 .

[14]  T. Parviainen,et al.  Organ doses and effective doses in pediatric radiography: Patient-dose survey in finland , 2009, Acta radiologica.

[15]  I. Koturbash,et al.  Environmental Research and Public Health Pediatric Exposures to Ionizing Radiation: Carcinogenic Considerations , 2022 .

[16]  W. J. Bair Overview of ICRP Respiratory Tract Model , 1991 .

[17]  K. Theodorou,et al.  Estimation of effective dose and radiation risk in pediatric barium studies procedures. , 2017, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.