In vivo bioluminescence and reflectance imaging of multiple organs in bioluminescence reporter mice by bundled-fiber-coupled microscopy.

Bioluminescence imaging (BLI) is used in biomedical research to monitor biological processes within living organisms. Recently, fiber bundles with high transmittance and density have been developed to detect low light with high resolution. Therefore, we have developed a bundled-fiber-coupled microscope with a highly sensitive cooled-CCD camera that enables the BLI of organs within the mouse body. This is the first report of in vivo BLI of the brain and multiple organs in luciferase-reporter mice using bundled-fiber optics. With reflectance imaging, the structures of blood vessels and organs can be seen clearly with light illumination, and it allowed identification of the structural details of bioluminescence images. This technique can also be applied to clinical diagnostics in a low invasive manner.

[1]  Marleen Keyaerts,et al.  Bioluminescence imaging: looking beyond the light. , 2012, Trends in molecular medicine.

[2]  B. Rice,et al.  Quantitative comparison of the sensitivity of detection of fluorescent and bioluminescent reporters in animal models. , 2004, Molecular imaging.

[3]  S. Nakanishi,et al.  Spatio‐temporal control of neural activity in vivo using fluorescence microendoscopy , 2012, The European journal of neuroscience.

[4]  Christian E Badr,et al.  Bioluminescence imaging: progress and applications. , 2011, Trends in biotechnology.

[5]  P. H. Yap,et al.  Determining refractive index of single living cell using an integrated microchip , 2007 .

[6]  S. Reppert,et al.  Coordination of circadian timing in mammals , 2002, Nature.

[7]  Takeharu Nagai,et al.  Luminescent proteins for high-speed single-cell and whole-body imaging , 2012, Nature Communications.

[8]  Y Sakaki,et al.  Resetting central and peripheral circadian oscillators in transgenic rats. , 2000, Science.

[9]  Jin U. Kang,et al.  Dark-field illuminated reflectance fiber bundle endoscopic microscope. , 2011, Journal of biomedical optics.

[10]  Wafik S El-Deiry,et al.  Bioluminescent Molecular Imaging of Endogenous and Exogenous p53-Mediated Transcription In Vitro and In Vivo Using an HCT116 Human Colon Carcinoma Xenograft Model , 2003, Cancer biology & therapy.

[11]  D. Taylor,et al.  Structural organization of interphase 3T3 fibroblasts studied by total internal reflection fluorescence microscopy , 1985, The Journal of cell biology.

[12]  Erik D Herzog,et al.  Photic and circadian expression of luciferase in mPeriod1-luc transgenic mice in vivo , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[13]  Feng Zhang,et al.  Channelrhodopsin-2 and optical control of excitable cells , 2006, Nature Methods.

[14]  Guang-Zhong Yang,et al.  Fiber bundle endocytoscopy. , 2013, Biomedical optics express.

[15]  Joel N. Bixler,et al.  Confocal Endomicroscopy: Instrumentation and Medical Applications , 2012, Annals of Biomedical Engineering.

[16]  R. Harper,et al.  Imaging of hippocampal neural activity in freely behaving animals , 1991, Behavioural Brain Research.

[17]  Yutaka Yamashita,et al.  In vivo visualization of hippocampal cells and dynamics of Ca2+ concentration during anoxia: feasibility of a fiber-optic plate microscope system for in vivo experiments , 1996, Brain Research.

[18]  Joseph S. Takahashi,et al.  Cell autonomy and synchrony of suprachiasmatic nucleus circadian oscillators , 2011, Trends in Neurosciences.

[19]  E. Cocker,et al.  Fiber-optic fluorescence imaging , 2005, Nature Methods.

[20]  Marleen Keyaerts,et al.  Dynamic bioluminescence imaging for quantitative tumour burden assessment using IV or IP administration of d-luciferin: effect on intensity, time kinetics and repeatability of photon emission , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[21]  Perry Ping Shum,et al.  Review of diverse optical fibers used in biomedical research and clinical practice. , 2014, Journal of biomedical optics.

[22]  B Messerschmidt,et al.  Endoscope-compatible confocal microscope using a gradient index-lens system , 2001 .

[23]  Takeharu Nagai,et al.  Recent progress in luminescent proteins development. , 2015, Current opinion in chemical biology.

[24]  Petros Giataganas,et al.  Color reflectance fiber bundle endomicroscopy without back-reflections , 2014, Journal of biomedical optics.

[25]  Kowa Koida,et al.  Activity-dependent signal changes in neurons by fiber-coupled microscopy , 2014, Photonics West - Biomedical Optics.

[26]  K. Wood THE CHEMICAL MECHANISM and EVOLUTIONARY DEVELOPMENT OF BEETLE BIOLUMINESCENCE , 1995 .

[27]  Gregor Eichele,et al.  RIGUI, a Putative Mammalian Ortholog of the Drosophila period Gene , 1997, Cell.

[28]  Haruhiko Soma,et al.  Transcriptional oscillation of canonical clock genes in mouse peripheral tissues , 2004, BMC Molecular Biology.

[29]  A. Mehta,et al.  In vivo mammalian brain imaging using one- and two-photon fluorescence microendoscopy. , 2004, Journal of neurophysiology.

[30]  D T Moore,et al.  Gradient-index optics: a review. , 1980, Applied optics.

[31]  K. Node,et al.  Compensation for intracellular environment in expression levels of mammalian circadian clock genes , 2014, Scientific Reports.

[32]  A. Miyawaki,et al.  Bioluminescent system for dynamic imaging of cell and animal behavior. , 2012, Biochemical and biophysical research communications.

[33]  Yoshiyuki Sakaki,et al.  Circadian oscillation of a mammalian homologue of the Drosophila period gene , 1997, Nature.

[34]  平野 雅彦 In vivo visualization of hippocampal cells and dynamics of Ca[2+] concentration during anoxia : Feasibility of a fiber-optic plate microscope system for in vivo experiments , 1997 .

[35]  Takashi Kudo,et al.  In Vivo Monitoring of Peripheral Circadian Clocks in the Mouse , 2012, Current Biology.

[36]  Masaru Murai,et al.  Endocytoscopy: novel endoscopic imaging technology for in-situ observation of bladder cancer cells. , 2006, Journal of endourology.

[37]  Yoshiyuki Sakaki,et al.  Constitutive expression of the Period1 gene impairs behavioral and molecular circadian rhythms. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[38]  Mark J Schnitzer,et al.  Fiber optic in vivo imaging in the mammalian nervous system , 2004 .

[39]  Rebekah Drezek,et al.  Needle-compatible single fiber bundle image guide reflectance endoscope. , 2010, Journal of biomedical optics.

[40]  Meir Nitzan,et al.  Pulse oximetry: fundamentals and technology update , 2014, Medical devices.

[41]  S. Shibata,et al.  Gene expression: View of a mouse clock gene ticking , 2001, Nature.

[42]  S. Miller,et al.  Beyond D-luciferin: expanding the scope of bioluminescence imaging in vivo. , 2014, Current opinion in chemical biology.

[43]  Y Sakaki,et al.  The human and mouse Period1 genes: five well-conserved E-boxes additively contribute to the enhancement of mPer1 transcription. , 2000, Genomics.