Low-dark-counting high-speed x-ray photon detection using an LSO Crystal and a small photomultiplier tube

To develop a dual-energy X-ray CT (DE-CT) system, we have performed investigation of high-speed dual-energy photon counting using two comparators and a low-dark-counting LSO-MPPC (multipixel photon counter) detector. To measure X-ray spectra, electric charges produced in the MPPC are converted into voltages and amplified by a highspeed current-voltage amplifier, and the event pulses are sent to a multichannel analyzer. The MPPC was driven under pre-Geiger mode at an MPPC bias voltage of 70.7 V. The event pulses are sent to two high-speed comparators for selecting two threshold energies to perform DE-CT. The ED-CT is accomplished by repeated linear scans and rotations of the object, and two sets of projection curves of the object are obtained simultaneously by the linear scan. In the DECT, two different-energy tomograms are obtained simultaneously, and photon-count energy subtraction imaging was carried out.

[1]  Katsuyuki Taguchi,et al.  Material separation in x-ray CT with energy resolved photon-counting detectors , 2011, Medical Imaging.

[2]  Eiichi Sato,et al.  100 μA-100 kV Photon-counting X-ray Computed Tomography System Using an LSO-MPPC Detector and a High-Speed Comparator and its Application to Gadolinium Imaging. , 2012, Journal of medical imaging and radiation sciences.

[3]  Eiichi Sato,et al.  Demonstration of enhanced iodine K-edge imaging using an energy-dispersive X-ray computed tomography system with a 25 mm/s-scan linear cadmium telluride detector and a single comparator. , 2012, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[4]  Eiichi Sato,et al.  Zero-dark-counting high-speed X-ray photon detection using a cerium-doped yttrium aluminum perovskite crystal and a small photomultiplier tube and its application to gadolinium imaging , 2014 .

[5]  Eiichi Sato,et al.  Application of an oscillation-type linear cadmium telluride detector to enhanced gadolinium K-edge computed tomography , 2011 .

[6]  Eiichi Sato,et al.  15Mcps photon-counting X-ray computed tomography system using a ZnO-MPPC detector and its application to gadolinium imaging. , 2012, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[7]  J. Schlomka,et al.  Multienergy photon-counting K-edge imaging: potential for improved luminal depiction in vascular imaging. , 2008, Radiology.

[8]  Eiichi Sato,et al.  Mcps-range photon-counting X-ray computed tomography system utilizing an oscillating linear-YAP(Ce) photon detector , 2011 .

[9]  Eiichi Sato,et al.  Investigation of Energy-Dispersive X-ray Computed Tomography System with CdTe Scan Detector and Comparing-Differentiator and Its Application to Gadolinium K-Edge Imaging , 2012 .