Self-switching and resistive circuits for a piezo patch in vibration suppression

A self-switching circuit and a resistive circuit are designed and implemented for vibration suppression with a piezo patch in this study. A numerical model is developed for a rectangular beam bonded with a pair of piezo patches. One piezo patch is used to excite the system, the other one being used for vibration damping. Optimal resistances are respectively determined for the resistive circuit and self-switching circuit, and a new switch law is proposed for the switching circuit. These two circuits are implemented in an experimental setup to verify the model. Experimental results show that the vibration of a clamped beam can be effectively damped by using the resistive circuit or switching circuit. Due to the fact that switching is not perfect in practice, the damping performance of the switching circuit is a little different from the simulated result.

[1]  Hyun-Kyu Kang,et al.  Measuring dynamic strain of structures using a gold-deposited extrinsic Fabry–Perot interferometer , 2003 .

[2]  Andrew J. Fleming,et al.  A broadband controller for shunt piezoelectric damping of structural vibration , 2003 .

[3]  G. Caruso A critical analysis of electric shunt circuits employed in piezoelectric passive vibration damping , 2001 .

[4]  K. W. Wang,et al.  Active-passive hybrid piezoelectric networks for vibration control: comparisons and improvement , 2001 .

[5]  Meng-Shiun Tsai,et al.  ON THE STRUCTURAL DAMPING CHARACTERISTICS OF ACTIVE PIEZOELECTRIC ACTUATORS WITH PASSIVE SHUNT , 1999 .

[6]  R. Blevins,et al.  Formulas for natural frequency and mode shape , 1984 .

[7]  Shan-Min Swei,et al.  Active actuation and control of a miniaturized suspension structure in hard-disk drives using a polyvinylidene-fluoride actuator and sensor , 2000 .

[8]  Daniel Guyomar,et al.  Semi-passive damping using continuous switching of a piezoelectric device , 1999, Smart Structures.

[9]  J. Chen,et al.  Response of large space structures with stiffness control , 1984 .

[10]  Nesbitt W. Hagood,et al.  Damping of structural vibrations with piezoelectric materials and passive electrical networks , 1991 .

[11]  Shu-yau Wu,et al.  Piezoelectric shunts with a parallel R-L circuit for structural damping and vibration control , 1996, Smart Structures.

[12]  Abdullah Al Mamun,et al.  Precision control of hard disk drives , 2005 .

[13]  Yaolong Lou,et al.  Detection and suppression for mechanical resonance in hard disk drives with built-in piezoelectric sensors , 2002, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[14]  Yanchu Xu,et al.  Dynamics analysis of constrained layer damping treated covers for hard disk drives , 2002, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[15]  Shu-yau Wu,et al.  Method for multiple-mode shunt damping of structural vibration using a single PZT transducer , 1998, Smart Structures.

[16]  Junjiro Onoda,et al.  Vibration Suppression by Variable-Stiffness Members , 1990 .

[17]  Seung-Bok Choi,et al.  Vibration control of an HDD disk-spindle system utilizing piezoelectric bimorph shunt damping: I. Dynamic analysis and modeling of the shunted drive , 2007 .

[18]  W. Clark Vibration Control with State-Switched Piezoelectric Materials , 2000 .