Movement related activity in the high gamma range of the human EEG

Electrocorticographic (ECoG) recordings obtained using intracranially implanted electrodes in epilepsy patients indicate that high gamma band (HGB) activity of sensorimotor cortex is focally increased during voluntary movement. These movement related HGB modulations may play an important role in sensorimotor cortex function. It is however currently not clear to what extent this type of neural activity can be detected using non-invasive electroencephalography (EEG) and how similar HGB responses in healthy human subjects are to those observed in epilepsy patients. Using the same arm reaching task, we have investigated spectral power changes both in intracranial ECoG recordings in epilepsy patients and in non-invasive EEG recordings optimized for detecting HGB activity in healthy subjects. Our results show a common HGB response pattern both in ECoG and EEG recorded above the sensorimotor cortex contralateral to the side of arm movement. In both cases, HGB activity increased around movement onset in the 60-90 Hz range and became most pronounced at reaching movement end. Additionally, we found EEG HGB activity above the frontal midline possibly generated by the anterior supplementary motor area (SMA), a region that was however not covered by the intracranial electrodes used in the present study. In summary, our findings show that HGB activity from human sensorimotor cortex can be non-invasively detected in healthy subjects using EEG, opening a new perspective for investigating the role of high gamma range neuronal activity both in function and dysfunction of the human cortical sensorimotor network.

[1]  G. Ojemann,et al.  Increased gamma-range activity in human sensorimotor cortex during performance of visuomotor tasks , 1999, Clinical Neurophysiology.

[2]  Christa Neuper,et al.  40-Hz oscillations during motor behavior in man , 1993, Neuroscience Letters.

[3]  François Mauguière,et al.  Intracerebral study of gamma rhythm reactivity in the sensorimotor cortex , 2005, The European journal of neuroscience.

[4]  E. Whitham,et al.  Scalp electrical recording during paralysis: Quantitative evidence that EEG frequencies above 20Hz are contaminated by EMG , 2007, Clinical Neurophysiology.

[5]  J. Schoffelen,et al.  Neuronal Coherence as a Mechanism of Effective Corticospinal Interaction , 2005, Science.

[6]  R. Lesser,et al.  Functional mapping of human sensorimotor cortex with electrocorticographic spectral analysis. I. Alpha and beta event-related desynchronization. , 1998, Brain : a journal of neurology.

[7]  N. E. Crone,et al.  Computationally efficient approaches to calculating significant ERD/ERS changes in the time–frequency plane , 2005, Journal of Neuroscience Methods.

[8]  G. Pfurtscheller,et al.  Event-related dynamics of cortical rhythms: frequency-specific features and functional correlates. , 2001, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[9]  Charles L. Wilson,et al.  Quantitative analysis of high-frequency oscillations (80-500 Hz) recorded in human epileptic hippocampus and entorhinal cortex. , 2002, Journal of neurophysiology.

[10]  Michael R. Chernick,et al.  Wavelet Methods for Time Series Analysis , 2001, Technometrics.

[11]  Ichiro Shimoyama,et al.  Event-related dynamics of the gamma-band oscillation in the human brain: information processing during a GO/NOGO hand movement task , 1999, Neuroscience Research.

[12]  Werner Lutzenberger,et al.  Dynamics of Gamma-Band Activity during an Audiospatial Working Memory Task in Humans , 2002, The Journal of Neuroscience.

[13]  N. Crone,et al.  High-frequency gamma oscillations and human brain mapping with electrocorticography. , 2006, Progress in brain research.

[14]  Sven P. Heinrich,et al.  High-frequency oscillations in human visual cortex do not mirror retinal frequencies , 2004, Neuroscience Letters.

[15]  Marie-Claude Hepp-Reymond,et al.  Gamma-range corticomuscular coherence during dynamic force output , 2007, NeuroImage.

[16]  R. C. Oldfield The assessment and analysis of handedness: the Edinburgh inventory. , 1971, Neuropsychologia.

[17]  Werner Lutzenberger,et al.  Distinct Gamma-Band Components Reflect the Short-Term Memory Maintenance of Different Sound Lateralization Angles , 2008, Cerebral cortex.

[18]  R. Lesser,et al.  Functional mapping of human sensorimotor cortex with electrocorticographic spectral analysis. II. Event-related synchronization in the gamma band. , 1998, Brain : a journal of neurology.

[19]  R J Ilmoniemi,et al.  Estimates of neuronal current distributions. , 1991, Acta oto-laryngologica. Supplementum.

[20]  K. Sekihara,et al.  Spatial Localization of Cortical Time-Frequency Dynamics , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  Simon B. Eickhoff,et al.  A new SPM toolbox for combining probabilistic cytoarchitectonic maps and functional imaging data , 2005, NeuroImage.

[22]  D. Krieger,et al.  High frequency scalp potentials evoked by a reaction time task. , 1987, Electroencephalography and clinical neurophysiology.

[23]  Ernst Fernando Lopes Da Silva Niedermeyer,et al.  Electroencephalography, basic principles, clinical applications, and related fields , 1982 .

[24]  C. Mehring,et al.  Encoding of Movement Direction in Different Frequency Ranges of Motor Cortical Local Field Potentials , 2005, The Journal of Neuroscience.

[25]  R. Hari,et al.  Synchronous cortical oscillatory activity during motor action , 2003, Current Opinion in Neurobiology.

[26]  Philippe Kahane,et al.  High gamma frequency oscillatory activity dissociates attention from intention in the human premotor cortex , 2005, NeuroImage.

[27]  B. Conway,et al.  Synchronization between motor cortex and spinal motoneuronal pool during the performance of a maintained motor task in man. , 1995, The Journal of physiology.

[28]  Gerwin Schalk,et al.  A brain–computer interface using electrocorticographic signals in humans , 2004, Journal of neural engineering.

[29]  I. Fried,et al.  Coupling Between Neuronal Firing, Field Potentials, and fMRI in Human Auditory Cortex , 2005, Science.

[30]  Rajesh P. N. Rao,et al.  Spectral Changes in Cortical Surface Potentials during Motor Movement , 2007, The Journal of Neuroscience.

[31]  S. P. Levine,et al.  Spatiotemporal patterns of beta desynchronization and gamma synchronization in corticographic data during self-paced movement , 2003, Clinical Neurophysiology.

[32]  B. Gordon,et al.  Induced electrocorticographic gamma activity during auditory perception. Brazier Award-winning article, 2001. , 2001, Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology.

[33]  B. Feige,et al.  The Role of Higher-Order Motor Areas in Voluntary Movement as Revealed by High-Resolution EEG and fMRI , 1999, NeuroImage.

[34]  G. Schalk,et al.  ELECTROCORTICOGRAPHIC FREQUENCY ALTERATION MAPPING: A CLINICAL TECHNIQUE FOR MAPPING THE MOTOR CORTEX , 2007, Neurosurgery.

[35]  José del R. Millán,et al.  Very high frequency oscillations (VHFO) as a predictor of movement intentions , 2006, NeuroImage.

[36]  Ernst Niebur,et al.  High-frequency gamma activity (80–150Hz) is increased in human cortex during selective attention , 2008, Clinical Neurophysiology.

[37]  W. Freeman,et al.  Spatial spectral analysis of human electrocorticograms including the alpha and gamma bands , 2000, Journal of Neuroscience Methods.

[38]  Gerhard Schneider,et al.  High-frequency Components of Auditory Evoked Potentials Are Detected in Responsive but Not in Unconscious Patients , 2005, Anesthesiology.

[39]  W. Singer,et al.  Hemodynamic Signals Correlate Tightly with Synchronized Gamma Oscillations , 2005, Science.

[40]  Masako Okamoto,et al.  Three-dimensional probabilistic anatomical cranio-cerebral correlation via the international 10–20 system oriented for transcranial functional brain mapping , 2004, NeuroImage.

[41]  H. Shibasaki,et al.  Movement-related change of electrocorticographic activity in human supplementary motor area proper. , 2000, Brain : a journal of neurology.

[42]  J. Wolpaw,et al.  EMG contamination of EEG: spectral and topographical characteristics , 2003, Clinical Neurophysiology.

[43]  A. Schnitzler,et al.  Physiological and pathological oscillatory networks in the human motor system , 2006, Journal of Physiology-Paris.

[44]  G. Pfurtscheller,et al.  Simultaneous EEG 10 Hz desynchronization and 40 Hz synchronization during finger movements. , 1992, Neuroreport.

[45]  B. Gordon,et al.  Induced electrocorticographic gamma activity during auditory perception , 2001, Clinical Neurophysiology.

[46]  M. Fuchs,et al.  Linear and nonlinear current density reconstructions. , 1999, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[47]  S. Baker,et al.  Network oscillations and intrinsic spiking rhythmicity do not covary in monkey sensorimotor areas , 2007, The Journal of physiology.

[48]  C. Crainiceanu,et al.  Electrocorticographic high gamma activity versus electrical cortical stimulation mapping of naming. , 2005, Brain : a journal of neurology.

[49]  J. Bouyer,et al.  Anatomical localization of cortical beta rhythms in cat , 1987, Neuroscience.

[50]  M. Berger,et al.  High Gamma Power Is Phase-Locked to Theta Oscillations in Human Neocortex , 2006, Science.

[51]  N. Logothetis,et al.  Neurophysiological investigation of the basis of the fMRI signal , 2001, Nature.

[52]  W. Cobb,et al.  The latency and form in man of the occipital potentials evoked by bright flashes , 1960, The Journal of physiology.