A miniature and low-cost glucose measurement system

Abstract One of the bottlenecks in widespread adoption of biosensors is the large and sophisticated bioanalytical system that is required to perform signal transduction and analysis. A miniaturized bioanalytical system facilitates biosensing techniques that are portable, easy to handle and inexpensive for fast and reliable measurements of biochemical species. Thus, downscaling the bioanalytical system has become a highly active research area, significantly assisted by recent advances in the microelectronics technology. In this work, a miniaturized system is designed and implemented for amperometric detection, and subsequently tested with a glucose biosensor based on the one-step approach utilizing water soluble poly(o-aminophenol). Several experiments are conducted to assess the viability of this system including calibration, interference and application tests. The results are compared with the previously published work performed using the same biosensor tested with a commercial potentiostat in order to verify the applicability of the designed system.

[1]  Zeynep Altintas,et al.  Lab-on-a-chip based biosensor for the real-time detection of aflatoxin. , 2016, Talanta.

[2]  Kevin W. Plaxco,et al.  CheapStat: An Open-Source, “Do-It-Yourself” Potentiostat for Analytical and Educational Applications , 2011, PloS one.

[3]  Shen-ming Chen,et al.  Amperometric glucose biosensor based on glucose oxidase dispersed in multiwalled carbon nanotubes/graphene oxide hybrid biocomposite. , 2014, Materials science & engineering. C, Materials for biological applications.

[4]  D. Chan,et al.  Immunosensors--principles and applications to clinical chemistry. , 2001, Clinica chimica acta; international journal of clinical chemistry.

[5]  M. Şenel,et al.  Novel reagentless glucose biosensor based on ferrocene cored asymmetric PAMAM dendrimers , 2013 .

[6]  S. Cosnier Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review. , 1999, Biosensors & bioelectronics.

[7]  S. Dong,et al.  The direct electron transfer of glucose oxidase and glucose biosensor based on carbon nanotubes/chitosan matrix. , 2005, Biosensors & bioelectronics.

[8]  Mitsuyuki Morita,et al.  Electrochromic behavior and stability of polyaniline composite films combined with prussian blue , 1994 .

[9]  Alan G. MacDiarmid,et al.  ‘Polyaniline’: Protonic acid doping of the emeraldine form to the metallic regime , 1986 .

[10]  Sum Huan Ng,et al.  Microfluidics biosensor chip with integrated screen-printed electrodes for amperometric detection of nerve agent , 2014 .

[11]  J. Haginaka,et al.  Determination of ATP and its metabolites released from rat caudal artery by isocratic ion-pair reversed-phase high-performance liquid chromatography. , 1998, Analytical biochemistry.

[12]  Ece Buber,et al.  Construction and amperometric biosensing performance of a novel platform containing carbon nanotubes-zinc phthalocyanine and a conducting polymer. , 2017, International journal of biological macromolecules.

[13]  V. Tomás,et al.  Determination of ATP via the photochemical generation of hydrogen peroxide using flow injection luminol chemiluminescence detection , 2003, Analytical and bioanalytical chemistry.

[14]  Jingjing Ye,et al.  Colorimetric visualization of glucose at the submicromole level in serum by a homogenous silver nanoprism-glucose oxidase system. , 2013, Analytical chemistry.

[15]  Yihe Zhang,et al.  Hierarchical composites of conductivity controllable polyaniline layers on the exfoliated graphite for dielectric application , 2012 .

[16]  G. Pacey,et al.  Determination of ATP using chelation-enhanced fluorescence. , 1996, Talanta.

[17]  Antonio Facchetti,et al.  π-Conjugated Polymers for Organic Electronics and Photovoltaic Cell Applications† , 2011 .

[18]  M. Shimomura,et al.  Amperometric glucose sensing with polyaniline/poly(acrylic acid) composite film bearing covalently-immobilized glucose oxidase: A novel method combining enzymatic glucose oxidation and cathodic O2 reduction , 2014 .

[19]  J. Vörös,et al.  Electrochemical Biosensors - Sensor Principles and Architectures , 2008 .

[20]  Y. Karatas,et al.  Synthesis and characterization of a novel polyphosphazene and its application to biosensor in combination with a conducting polymer , 2014 .

[21]  Joseph Wang Electrochemical glucose biosensors. , 2008, Chemical reviews.

[22]  Aaron R Wheeler,et al.  DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration , 2015, PloS one.

[23]  S. Ng,et al.  Lab-on-a-chip for rapid electrochemical detection of nerve agent Sarin , 2014, Biomedical microdevices.

[24]  Gabriele Meloni,et al.  Building a Microcontroller Based Potentiostat: A Inexpensive and Versatile Platform for Teaching Electrochemistry and Instrumentation , 2016 .

[25]  N. Sethy,et al.  A cost-effective volume miniaturized and microcontroller based cytochrome c assay , 2014 .

[26]  Rajesh,et al.  Biomolecular immobilization on conducting polymers for biosensing applications. , 2007, Biomaterials.

[27]  Yingchun Fu,et al.  Recent advances in electrochemical glucose biosensors: a review , 2013 .

[28]  A. Soldatkin,et al.  Amperometric biosensor system for simultaneous determination of adenosine-5'-triphosphate and glucose. , 2014, Analytical chemistry.

[29]  John R. Reynolds,et al.  Molecular Engineering of π-Conjugated Polymers , 1999 .

[30]  A. Turner,et al.  Home blood glucose biosensors: a commercial perspective. , 2005, Biosensors & bioelectronics.

[31]  Gordon G. Wallace,et al.  Electrofunctional polymers: their role in the development of new analytical systems , 1999 .

[32]  Alex Nemiroski,et al.  Universal mobile electrochemical detector designed for use in resource-limited applications , 2014, Proceedings of the National Academy of Sciences.

[33]  Eun-Hyung Yoo,et al.  Glucose Biosensors: An Overview of Use in Clinical Practice , 2010, Sensors.

[34]  Y. Udum,et al.  Polymerization and biosensor application of water soluble peptide-SNS type monomer conjugates. , 2017, Journal of materials chemistry. B.

[35]  Y. Yagcı,et al.  Poly(o-aminophenol) prepared by Cu(II) catalyzed air oxidation and its use as a bio-sensing architecture , 2017 .

[36]  L. Toppare,et al.  A bio-sensing platform utilizing a conjugated polymer, carbon nanotubes and PAMAM combination , 2017 .

[37]  L. Toppare,et al.  Selenium containing conducting polymer based pyranose oxidase biosensor for glucose detection. , 2015, Food chemistry.

[38]  A. Soldatkin,et al.  Microbiosensor based on glucose oxidase and hexokinase co-immobilised on platinum microelectrode for selective ATP detection. , 2009, Talanta.

[39]  Fabio Augusto,et al.  Point-of-use electroanalytical platform based on homemade potentiostat and smartphone for multivariate data processing , 2016 .

[40]  Njagi Jm,et al.  Diabetes mellitus ? a devastating metabolic disorder , 2015 .

[41]  Michael Holzinger,et al.  Adamantane/beta-cyclodextrin affinity biosensors based on single-walled carbon nanotubes. , 2009, Biosensors & bioelectronics.

[42]  B. Eggins Chemical Sensors and Biosensors , 2002 .