Development of Embedded EM Sensors for Estimating Tensile Forces of PSC Girder Bridges

The tensile force of pre-stressed concrete (PSC) girders is the most important factor for managing the stability of PSC bridges. The tensile force is induced using pre-stressing (PS) tendons of a PSC girder. Because the PS tendons are located inside of the PSC girder, the tensile force cannot be measured after construction using conventional NDT (non-destructive testing) methods. To monitor the induced tensile force of a PSC girder, an embedded EM (elasto-magnetic) sensor was proposed in this study. The PS tendons are made of carbon steel, a ferromagnetic material. The magnetic properties of the ferromagnetic specimen are changed according to the induced magnetic field, temperature, and induced stress. Thus, the tensile force of PS tendons can be estimated by measuring their magnetic properties. The EM sensor can measure the magnetic properties of ferromagnetic materials in the form of a B (magnetic density)-H (magnetic force) loop. To measure the B-H loop of a PS tendon in a PSC girder, the EM sensor should be embedded into the PSC girder. The proposed embedded EM sensor can be embedded into a PSC girder as a sheath joint by designing screw threads to connect with the sheath. To confirm the proposed embedded EM sensors, the experimental study was performed using a down-scaled PSC girder model. Two specimens were constructed with embedded EM sensors, and three sensors were installed in each specimen. The embedded EM sensor could measure the B-H loop of PS tendons even if it was located inside concrete, and the area of the B-H loop was proportionally decreased according to the increase in tensile force. According to the results, the proposed method can be used to estimate the tensile force of unrevealed PS tendons.

[1]  Bijan O Aalami Time‐dependent analysis of post‐tensioned concrete structures , 1998 .

[2]  Seok-Goo YOUN,et al.  DETERIORATION OF BONDED POST-TENSIONED CONCRETE BRIDGES AND RESEARCH TOPICS ON THE STRENGTH EVALUATION IN ISARC , 2006 .

[3]  Chung Bang Yun,et al.  Identification of prestress-loss in PSC beams using modal information , 2004 .

[4]  Seunghee Park,et al.  Visualization of Fatigue Cracks at Structural Members Using a Pulsed Laser Scanning System , 2015 .

[5]  Hung-Liang Roger Chen,et al.  MEASUREMENT OF TENSILE FORCES IN A SEVEN-WIRE PRESTRESSING STRAND USING STRESS WAVES , 2001 .

[6]  Seunghee Park,et al.  Integrating embedded piezoelectric sensors with continuous wavelet transforms for real-time concrete curing strength monitoring , 2015 .

[7]  G C Frantz,et al.  STRUCTURAL TESTS OF 27-YEAR-OLD PRESTRESSED CONCRETE BRIDGE BEAMS , 1991 .

[8]  Jong-Jae Lee,et al.  Magnetic Flux Leakage Sensing-Based Steel Cable NDE Technique , 2014 .

[9]  Ru Zhang,et al.  Smart elasto-magneto-electric (EME) sensors for stress monitoring of steel structures in railway infrastructures , 2011 .

[10]  Ming L. Wang,et al.  Fast EM stress sensors for large steel cables , 2008, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[11]  Junkyeong Kim,et al.  Advanced Fatigue Crack Detection Using Nonlinear Self-Sensing Impedance Technique for Automated NDE of Metallic Structures , 2015 .

[12]  Seunghee Park,et al.  Flaw Imaging Technique for Plate-Like Structures Using Scanning Laser Source Actuation , 2014 .

[13]  Kevin L. Rens,et al.  Review of nondestructive evaluation techniques of civil infrastructure , 1999 .

[14]  Yang Zhao,et al.  Steel stress monitoring sensor based on elasto-magnetic effect and using magneto-electric laminated composite , 2012 .

[15]  S A Freitag,et al.  Deterioration of Prestressed Concrete Bridge Beams , 2008 .

[16]  Jin-Hak Yi,et al.  Vibration and impedance monitoring for prestress-loss prediction in PSC girder bridges , 2009 .

[17]  Seunghee Park,et al.  Damage visualization of pipeline structures using laser-induced ultrasonic waves , 2015 .

[18]  Changbin Joh,et al.  Feasibility Study of Stress Measurement in Prestressing Tendons Using Villari Effect and Induced Magnetic Field , 2013, Int. J. Distributed Sens. Networks.

[19]  N. Lakshmanan,et al.  Experimental, numerical and analytical studies on a novel external prestressing technique for concrete structural components , 2009 .

[20]  Glenn Washer,et al.  Velocity Constants for Ultrasonic Stress Measurement in Prestressing Tendons , 2002 .

[21]  S K Kunnath,et al.  FIELD MEASUREMENT AND EVALUATION OF TIME-DEPENDENT LOSSES IN PRESTRESSED CONCRETE BRIDGES , 1997 .

[22]  Hyunwoo Kim,et al.  FBG Sensors Encapsulated into 7-Wire Steel Strand for Tension Monitoring of a Prestressing Tendon , 2012 .

[23]  Jinping Ou,et al.  Monitoring of structural prestress loss in RC beams by inner distributed Brillouin and fiber Bragg grating sensors on a single optical fiber , 2014 .

[24]  Ming L. Wang,et al.  Comparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge , 2013 .

[26]  Lawrence D. Reaveley,et al.  Post-tensioned Tendon Losses in a Spliced-Girder Bridge, Part 1: Field Measurements , 2007 .