Comparison of speed-accuracy tradeoff between linear and nonlinear filtering algorithms for myocontrol.

Nonlinear Bayesian filtering of surface electromyography (EMG) can provide a stable output signal with little delay and the ability to change rapidly, making it a potential control input for prosthetic or communication devices. We hypothesized that myocontrol follows Fitts' Law, and that Bayesian filtered EMG would improve movement times and success rates when compared with linearly filtered EMG. We tested the two filters using a Fitts' Law speed-accuracy paradigm in a one-muscle myocontrol task with EMG captured from the dominant first dorsal interosseous muscle. Cursor position in one dimension was proportional to EMG. Six indices of difficulty were tested, varying the target size and distance. We examined two performance measures: movement time (MT) and success rate. The filter had a significant effect on both MT and success. MT followed Fitts' Law and the speed-accuracy relationship exhibited a significantly higher channel capacity when using the Bayesian filter. Subjects seemed to be less cautious using the Bayesian filter due to its lower error rate and smoother control. These findings suggest that Bayesian filtering may be a useful component for myoelectrically controlled prosthetics or communication devices. NEW & NOTEWORTHY Whereas previous work has focused on assessing the Bayesian algorithm as a signal processing algorithm for EMG, this study assesses the use of the Bayesian algorithm for online EMG control. In other words, the subjects see the output of the filter and can adapt their own behavior to use the filter optimally as a tool. This study compares how subjects adapt EMG behavior using the Bayesian algorithm vs. a linear algorithm.

[1]  C M Light,et al.  Intelligent multifunction myoelectric control of hand prostheses , 2002, Journal of medical engineering & technology.

[2]  Philip A. Parker,et al.  Signal Processing for Proportional Myoelectric Control , 1984, IEEE Transactions on Biomedical Engineering.

[3]  I. Scott MacKenzie,et al.  Fitts' Law as a Research and Design Tool in Human-Computer Interaction , 1992, Hum. Comput. Interact..

[4]  Scott J. Young,et al.  Cathodal Transcranial Direct Current Stimulation in Children With Dystonia , 2014, Journal of child neurology.

[5]  D. Richard Brown,et al.  Adaptive whitening in electromyogram amplitude estimation for epoch-based applications , 2005, IEEE Transactions on Biomedical Engineering.

[6]  E. Clancy,et al.  Influence of smoothing window length on electromyogram amplitude estimates , 1998, IEEE Transactions on Biomedical Engineering.

[7]  I. Scott MacKenzie,et al.  Accuracy measures for evaluating computer pointing devices , 2001, CHI.

[8]  Kevin B. Englehart,et al.  A wavelet-based continuous classification scheme for multifunction myoelectric control , 2001, IEEE Transactions on Biomedical Engineering.

[9]  Scott J. Young,et al.  Visual Feedback Reduces Co-contraction in Children With Dystonia , 2011, Journal of child neurology.

[10]  Stuart K. Card,et al.  Evaluation of mouse, rate-controlled isometric joystick, step keys, and text keys, for text selection on a CRT , 1987 .

[11]  M. Osman Tokhi,et al.  A fuzzy clustering neural network architecture for multifunction upper-limb prosthesis , 2003, IEEE Transactions on Biomedical Engineering.

[12]  Neville Hogan,et al.  Myoelectric Signal Processing: Optimal Estimation Applied to Electromyography - Part II: Experimental Demonstration of Optimal Myoprocessor Performance , 1980, IEEE Transactions on Biomedical Engineering.

[13]  G. Zorzi,et al.  EMG-Based Visual-Haptic Biofeedback: A Tool to Improve Motor Control in Children With Primary Dystonia , 2013, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[14]  S. Meek,et al.  Comparison of signal-to-noise ratio of myoelectric filters for prosthesis control. , 1992, Journal of rehabilitation research and development.

[15]  Edward A. Clancy,et al.  Adaptive whitening of the electromyogram to improve amplitude estimation , 2000, IEEE Transactions on Biomedical Engineering.

[16]  Terence D Sanger,et al.  Bayesian filtering of myoelectric signals. , 2007, Journal of neurophysiology.

[17]  B. Kantowitz,et al.  Fitts' law with an isometric controller: effects of order of control and control-display gain. , 1988, Journal of motor behavior.

[18]  Adrian D. C. Chan,et al.  Continuous myoelectric control for powered prostheses using hidden Markov models , 2005, IEEE Transactions on Biomedical Engineering.

[19]  B. Hudgins,et al.  Hidden Markov model classification of myoelectric signals in speech , 2002 .

[20]  Garrett B. Stanley,et al.  Design and implementation of a hands-free electrolarynx device controlled by neck strap muscle electromyographic activity , 2004, IEEE Transactions on Biomedical Engineering.

[21]  N. Hogan,et al.  Probability density of the surface electromyogram and its relation to amplitude detectors , 1999, IEEE Transactions on Biomedical Engineering.

[22]  Adrian D. C. Chan,et al.  A Gaussian mixture model based classification scheme for myoelectric control of powered upper limb prostheses , 2005, IEEE Transactions on Biomedical Engineering.

[23]  T. Sanger,et al.  Prolonged Electromyogram Biofeedback Improves Upper Extremity Function in Children With Cerebral Palsy , 2010, Journal of child neurology.

[24]  Han-Pang Huang,et al.  Recognition of Electromyographic Signals Using Cascaded Kernel Learning Machine , 2007, IEEE/ASME Transactions on Mechatronics.

[25]  N. Hogan,et al.  Customized interactive robotic treatment for stroke: EMG-triggered therapy , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[26]  Martin Arguin,et al.  Speed-accuracy trade-offs in myocontrol. , 2006, Human movement science.

[27]  Robert W. Mann,et al.  Myoelectric Signal Processing: Optimal Estimation Applied to Electromyography - Part I: Derivation of the Optimal Myoprocessor , 1980, IEEE Transactions on Biomedical Engineering.

[28]  Woojin Chung,et al.  Comparison of myocontrol and force control based on fitts’ law model , 2011 .

[29]  S Micera,et al.  Control of Hand Prostheses Using Peripheral Information , 2010, IEEE Reviews in Biomedical Engineering.

[30]  Panagiotis K. Artemiadis,et al.  A Switching Regime Model for the EMG-Based Control of a Robot Arm , 2011, IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics).

[31]  P. Fitts The information capacity of the human motor system in controlling the amplitude of movement. , 1954, Journal of experimental psychology.