Microwave applicator for hyperthermia treatment on in vivo melanoma model

In this article, we evaluated a planar microwave applicator for in vivo superficial hyperthermia treatments on small tumors in the mouse mimicking treatments for human neoplasms. The design of the applicator, was challenged by the small dimensions of the tumors and unwanted diffusion of heating in the tumor-bearing animals. The required solution was to limit the penetration of microwaves in the depth of the tissue maintaining the full efficacy of hyperthermia. The study was firstly performed by computer simulations of SAR distribution inside a flat homogeneous phantom, considering various thicknesses of the integrated water bolus. Simulations, validated by the measurements, were also used to evaluate the impedance matching. Further tests were performed on homogeneous agar phantom to simulate the temperature distribution in the biological tissue and to preliminary assess the possible modality and schedule of microwave hyperthermia delivery. The in vivo experiments showed the evidence of direct microwave-induced heating and damage of the melanoma tissue in a range of penetration coherent both with computer simulations and phantom studies. The described approach appears perspective for designing limited-microwave-delivery applicators tailored for treatments of human superficial tumors and pre-tumoral lesions.

[1]  J. Trachtenberg,et al.  Interstitial microwave thermal therapy and its application to the treatment of recurrent prostate cancer , 2004, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[2]  Marleen de Bruijne,et al.  Development of a guideline for the water bolus temperature in superficial hyperthermia , 2006, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[3]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[4]  S. Davidson,et al.  Infrared thermographic SAR measurements of interstitial hyperthermia applicators: errors due to thermal conduction and convection , 2004, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[5]  K. Yee Numerical solution of initial boundary value problems involving maxwell's equations in isotropic media , 1966 .

[6]  J W Hand,et al.  Quality assurance guidelines for ESHO protocols. , 1989, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[7]  R K Jain,et al.  Differential response of normal and tumor microcirculation to hyperthermia. , 1984, Cancer research.

[8]  L. Kubínová,et al.  Imaging of mouse experimental melanoma in vivo and ex vivo by combination of confocal and nonlinear microscopy , 2009, Microscopy research and technique.

[9]  C. J. Prior,et al.  Microstrip disc antenna with short-circuited annular ring , 1985 .

[10]  G C van Rhoon,et al.  A 433 MHz Lucite cone waveguide applicator for superficial hyperthermia. , 1998, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[11]  J. Vrba,et al.  Evanescent-mode applicators (EMA) for superficial and subcutaneous hyperthermia , 1993, IEEE Transactions on Biomedical Engineering.

[12]  P R Stauffer,et al.  Characterization of a digital microwave radiometry system for noninvasive thermometry using a temperature-controlled homogeneous test load , 2008, Physics in Medicine and Biology.

[13]  Margarethus M. Paulides,et al.  A Patch Antenna Design for Application in a Phased-Array Head and Neck Hyperthermia Applicator , 2007, IEEE Transactions on Biomedical Engineering.

[14]  Allen Taflove,et al.  Computational Electrodynamics the Finite-Difference Time-Domain Method , 1995 .

[15]  Allen Taflove,et al.  Application of the Finite-Difference Time-Domain Method to Sinusoidal Steady-State Electromagnetic-Penetration Problems , 1980, IEEE Transactions on Electromagnetic Compatibility.

[16]  Steven L. Dvorak,et al.  Numerical analysis of printed strip dipole hyperthermia applicators , 1995 .

[17]  W. J. Ellison,et al.  Water: a dielectric reference , 1996 .

[18]  Ashutosh Kumar Singh,et al.  Experience with a small animal hyperthermia ultrasound system (SAHUS): report on 83 tumours , 2005, Physics in medicine and biology.

[19]  Constantine A. Balanis,et al.  Antenna Theory: Analysis and Design , 1982 .

[20]  T. Samaras,et al.  Theoretical investigation of measurement procedures for the quality assurance of superficial hyperthermia applicators , 2002, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[21]  Paul R Stauffer,et al.  Can we settle with single-band radiometric temperature monitoring during hyperthermia treatment of chestwall recurrence of breast cancer using a dual-mode transceiving applicator? , 2007, Physics in medicine and biology.

[22]  J. Zee,et al.  HYPERTHERMIA IN RECURRENT BREAST CANCER : FROM EXPERIMENTAL ONCOLOGY TO STANDARD PRACTICE , 2002 .