Four‐dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent

Magnetic resonance microscopy (MRM) has become an important tool for small animal cardiac imaging. In relation to competing technologies (microCT and ultrasound), MR is limited by spatial resolution, temporal resolution, and acquisition time. All three of these limitations have been addressed by developing a four‐dimensional (4D) (3D plus time) radial acquisition (RA) sequence. The signal‐to‐noise ratio (SNR) has been optimized by minimizing the echo time (TE) (300 us). The temporal resolution and throughput have been improved by center‐out trajectories resulting in repetition time (TR) <2.5 ms. The contrast has been enhanced through the use of a liposomal blood pool agent that reduces the T1 of the blood to <400 ms. We have developed protocols for three specific applications: 1) high‐throughput with spatial resolution of 87 × 87 × 352 um3 (voxel volume = 2.7 nL) and acquisition time of 16 min; 2) high‐temporal resolution with spatial resolution of 87 × 87 × 352 um3 (voxel volume = 2.7 nL) and temporal resolution at 4.8 ms and acquisition time of 32 minutes; and 3) high‐resolution isotropic imaging at 87 × 87 × 87 um3 (voxel volume = 0.68 nL) and acquisition time of 31 min. The 4D image arrays allow direct measure of cardiac functional parameters dependent on chamber volumes, e.g., ejection fraction (EF), end diastolic volume (EDV), and end systolic volume (ESV). Magn Reson Med 60:111–118, 2008. © 2008 Wiley‐Liss, Inc.

[1]  G Allan Johnson,et al.  4-D Micro-CT of the Mouse Heart , 2005, Molecular imaging.

[2]  Klaas Nicolay,et al.  Comparison between prospective and retrospective triggering for mouse cardiac MRI , 2007, NMR in biomedicine.

[3]  Stefan Neubauer,et al.  High‐resolution MRI with cardiac and respiratory gating allows for accurate in vivo atherosclerotic plaque visualization in the murine aortic arch , 2003, Magnetic resonance in medicine.

[4]  Daniel B Ennis,et al.  3D breath‐held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI , 2004, Journal of magnetic resonance imaging : JMRI.

[5]  P. Lauterbur,et al.  Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance , 1973, Nature.

[6]  Katherine C. Wu,et al.  High temporal resolution breathheld 3D FIESTA CINE imaging: Validation of ventricular function in patients with chronic myocardial infarction , 2007, Journal of magnetic resonance imaging : JMRI.

[7]  Matthias Nahrendorf,et al.  Cardiac MRI in mice at 9.4 Tesla with a transmit‐receive surface coil and a cardiac‐tailored intensity‐correction algorithm , 2007, Journal of magnetic resonance imaging : JMRI.

[8]  Kamesh Namuduri,et al.  A Decision Support Framework for Automated Screening of Diabetic Retinopathy , 2006, Int. J. Biomed. Imaging.

[9]  A Haase,et al.  Magnetic resonance imaging of coronary arteries and heart valves in a living mouse: techniques and preliminary results. , 2000, Journal of magnetic resonance.

[10]  Z. Fayad,et al.  Characterization of aortic root atherosclerosis in ApoE knockout mice: High‐resolution in vivo and ex vivo MRM with histological correlation , 2003, Magnetic resonance in medicine.

[11]  Walter F Block,et al.  Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory , 2002, Magnetic resonance in medicine.

[12]  J R MacFall,et al.  MR microscopy of the rat lung using projection reconstruction , 1993, Magnetic resonance in medicine.

[13]  Anja C S Brau,et al.  Cine magnetic resonance microscopy of the rat heart using cardiorespiratory‐synchronous projection reconstruction , 2004, Journal of magnetic resonance imaging : JMRI.

[14]  Y Amano,et al.  Three‐dimensional cardiac cine magnetic resonance imaging with an ultrasmall superparamagnetic iron oxide blood pool agent (NC100150) , 2000, Journal of magnetic resonance imaging : JMRI.

[15]  Martin J. Lohse,et al.  Dobutamine-Stress Magnetic Resonance Microimaging in Mice: Acute Changes of Cardiac Geometry and Function in Normal and Failing Murine Hearts , 2001, Circulation research.

[16]  S. Neubauer,et al.  Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields , 2004, Journal of magnetic resonance imaging : JMRI.

[17]  A. Song,et al.  An improved gridding method for spiral MRI using nonuniform fast Fourier transform. , 2003, Journal of magnetic resonance.

[18]  B K Rutt,et al.  Effects of polar sampling in k‐space , 1996, Magnetic resonance in medicine.

[19]  Pierre Croisille,et al.  Cardiac and respiratory double self‐gated cine MRI in the mouse at 7 T , 2006, Magnetic resonance in medicine.

[20]  G Allan Johnson,et al.  High-resolution imaging of murine myocardial infarction with delayed-enhancement cine micro-CT. , 2007, American journal of physiology. Heart and circulatory physiology.

[21]  Wilson Fong Handbook of MRI Pulse Sequences , 2005 .

[22]  Maria I Altbach,et al.  View‐ordering in radial fast spin‐echo imaging , 2004, Magnetic resonance in medicine.

[23]  Rong Zhou,et al.  Assessment of global and regional myocardial function in the mouse using cine and tagged MRI , 2003, Magnetic resonance in medicine.

[24]  D. Peters,et al.  Undersampled projection reconstruction applied to MR angiography , 2000, Magnetic resonance in medicine.

[25]  B. Bruneau,et al.  4D cardiac MRI in the mouse , 2007, NMR in biomedicine.

[26]  Sam T. S. Wong,et al.  A strategy for sampling on a sphere applied to 3D selective RF pulse design , 1994, Magnetic resonance in medicine.

[27]  P A Narayana,et al.  High-resolution vascular imaging of the rat spine using liposomal blood pool MR agent. , 2007, AJNR. American journal of neuroradiology.

[28]  Christopher M Kramer,et al.  Black blood gradient echo cine magnetic resonance imaging of the mouse heart , 2005, Magnetic resonance in medicine.

[29]  Dirk van Ormondt,et al.  Dynamic MR-Imaging with Radial Scanning, a Post-Acquisition Keyhole Approach , 2003, EURASIP J. Adv. Signal Process..

[30]  Stefan Neubauer,et al.  Quantitative 3-Dimensional Echocardiography for Accurate and Rapid Cardiac Phenotype Characterization in Mice , 2004, Circulation.

[31]  Q. Liu,et al.  An accurate algorithm for nonuniform fast Fourier transforms (NUFFT's) , 1998 .

[32]  W. Gilson,et al.  Serial MRI evaluation of cardiac structure and function in mice after reperfused myocardial infarction , 2002, Magnetic resonance in medicine.

[33]  Qing Huo Liu,et al.  Improving Non-Cartesian MRI Reconstruction through Discontinuity Subtraction , 2006, Int. J. Biomed. Imaging.

[34]  G. Johnson,et al.  Ventilation‐synchronous magnetic resonance microscopy of pulmonary structure and ventilation in mice , 2005, Magnetic resonance in medicine.

[35]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[36]  T M Grist,et al.  Single breath‐hold 3D contrast‐enhanced method for assessment of cardiac function , 2000, Magnetic resonance in medicine.