Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps

Conventional wisdom is that breath acetone may be markedly elevated in type 1 diabetes, but that this only occurs during poor blood glucose control and/or intercurrent illness. In contrast, little is known about breath acetone at more representative everyday blood glucose levels in diabetes. We used selected ion flow tube mass spectrometry to monitor the breath of eight patients with type 1 diabetes mellitus during 'insulin clamp' studies in which insulin and glucose were infused into patients to lower blood glucose levels in steps from normal values into the low glucose (hypoglycaemic) range. The concentration of acetone in breath and the blood sugar concentration of the patients were monitored at each blood glucose concentration. The blood glucose level at the start of the study was typically about 6 mM L(-1), whereas the breath acetone concentration at this blood glucose level was unexpectedly variable, ranging from 1 part-per-million to 21 ppm, in contrast to what was previously believed, i.e. that type 1 diabetes mellitus is characterized by high acetone levels. In all eight patients, the breath acetone declined linearly with blood glucose concentration.

[1]  David Smith,et al.  A longitudinal study of ammonia, acetone and propanol in the exhaled breath of 30 subjects using selected ion flow tube mass spectrometry, SIFT-MS , 2006, Physiological measurement.

[2]  H. Byun,et al.  Analysis of diabetic patient's breath with conducting polymer sensor array , 2005 .

[3]  M. Kalapos,et al.  On the mammalian acetone metabolism: from chemistry to clinical implications. , 2003, Biochimica et biophysica acta.

[4]  P. Španěl,et al.  SIFT studies of the reactions of H3O+, NO+ and O2+ with a series of aldehydes and ketones , 1997 .

[5]  山根 則夫 Relationship between skin acetone and blood β-hydroxybutyrate concentrations in diabetes , 2006 .

[6]  David Smith,et al.  Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis. , 2005, Mass spectrometry reviews.

[7]  P. Španěl,et al.  Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath , 1996, Medical and Biological Engineering and Computing.

[8]  P. Španěl,et al.  SIFT studies of the reactions of H3O+, NO+ and O+2 with a series of volatile carboxylic acids and esters , 1998 .

[9]  Jianzhong Li,et al.  Determination of acetone in breath , 2005 .

[10]  I. Ray,et al.  Detection of biomarker in breath: A step towards noninvasive diabetes monitoring , 2008 .

[11]  H. Arnqvist,et al.  Concentrations of acetone in venous blood samples from drunk drivers, type-I diabetic outpatients, and healthy blood donors. , 1993, Journal of analytical toxicology.

[12]  R. Hoeldtke,et al.  Acetone Metabolism During Diabetic Ketoacidosis , 1982, Diabetes.

[13]  David Smith,et al.  A general method for the calculation of absolute trace gas concentrations in air and breath from selected ion flow tube mass spectrometry data , 2006 .

[14]  David Smith,et al.  A longitudinal study of methanol in the exhaled breath of 30 healthy volunteers using selected ion flow tube mass spectrometry, SIFT-MS , 2006, Physiological measurement.

[15]  P. Španěl,et al.  A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS) , 2006, Physiological measurement.

[16]  L. Laffel Ketone bodies: a review of physiology, pathophysiology and application of monitoring to diabetes , 1999, Diabetes/metabolism research and reviews.

[17]  Tianshu Wang,et al.  Generation of volatile compounds on mouth exposure to urea and sucrose: implications for exhaled breath analysis , 2006, Physiological measurement.

[18]  S. Amiel,et al.  Delay in onset of awareness of acute hypoglycemia and of restoration of cognitive performance during recovery. , 2000, Diabetes care.

[19]  David Smith,et al.  A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry. , 2006, Rapid communications in mass spectrometry : RCM.

[20]  David Smith,et al.  The concentration distributions of some metabolites in the exhaled breath of young adults , 2007, Journal of breath research.

[21]  M. Evans,et al.  An exploratory comparative study of volatile compounds in exhaled breath and emitted by skin using selected ion flow tube mass spectrometry. , 2008, Rapid communications in mass spectrometry : RCM.

[22]  P. Španěl,et al.  The challenge of breath analysis for clinical diagnosis and therapeutic monitoring. , 2007, The Analyst.

[23]  X. Zhang,et al.  Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[24]  Patrik Španěl,et al.  Application of ion chemistry and the SIFT technique to the quantitative analysis of trace gases in air and on breath , 1996 .

[25]  P. Španěl,et al.  Trace gases in breath of healthy volunteers when fasting and after a protein-calorie meal: a preliminary study. , 1999, Journal of applied physiology.

[26]  D. Hopkins,et al.  Alanine infusion during hypoglycaemia partly supports cognitive performance in healthy human subjects , 2004, Diabetic medicine : a journal of the British Diabetic Association.

[27]  D. Ruta,et al.  Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database , 1999, BMJ.