Impact of Harmonics and Unbalance on the Dynamics of Grid-Forming, Frequency-Droop-Controlled Inverters

Due to its multiple advantages, the grid-forming, droop-controlled (GFDC) inverter is a strong contender for large-scale deployment in the future power systems. However, it is still unclear whether higher harmonics can play an important role in the dynamics of GFDC inverter networks. The major objective of this article is to gain insight into whether certain higher harmonics influence or interact with GFDC inverter network dynamics and to characterize this harmonic interaction. For this purpose, a multiple-harmonic dynamic phasor model (DPM) of a representative GFDC network is derived, which can be conveniently extended to hundreds of DPM equations in order to rigorously investigate the effects of dc offsets and/or second-harmonic content, six-step switching harmonics, and unbalance. For a representative network, the results from eigenvalue migration studies show that GFDC dynamics are not strongly influenced by the presence of six-step switching harmonics nor unbalance. For the first time, it is shown that under conditions of high droop slope and high-bandwidth power filtering, dc offsets and second-harmonic content can excite a resonance within the network and even influence the location of the eigenvalues of the linearized DPM. All DPM results are thoroughly validated using Simulink, and the selected results are validated experimentally using the Wisconsin Energy Institute (WEI) microgrid testbed.

[1]  A. Yacamini,et al.  Harmonics produced by direct current in convertor transformers , 1978 .

[2]  Vaithianathan Venkatasubramanian,et al.  Tools for dynamic analysis of the general large power system using time-varying phasors , 1994 .

[3]  J. M. Noworolski,et al.  Generalized averaging method for power conversion circuits , 1990, 21st Annual IEEE Conference on Power Electronics Specialists.

[4]  Andrew D. Paquette,et al.  Virtual Impedance Current Limiting for Inverters in Microgrids With Synchronous Generators , 2013, IEEE Transactions on Industry Applications.

[5]  Josep M. Guerrero,et al.  Dynamic-phasor-based nonlinear modelling of AC islanded microgrids under droop control , 2014, 2014 IEEE 11th International Multi-Conference on Systems, Signals & Devices (SSD14).

[6]  Josep M. Guerrero,et al.  Dynamic-Phasor Modeling and Transient Analysis of Inverter-Based Microgrid Under Unbalanced and Harmonic Condition , 2018, 2018 IEEE Energy Conversion Congress and Exposition (ECCE).

[7]  Mohsen Hamzeh,et al.  A New Control Strategy for a Multi-Bus MV Microgrid Under Unbalanced Conditions , 2012, IEEE Transactions on Power Systems.

[8]  Lena Jaeger,et al.  Vector Control And Dynamics Of Ac Drives , 2016 .

[9]  T. M. Jahns,et al.  Comparison of Grid Following and Grid Forming Control for a High Inverter Penetration Power System , 2018, 2018 IEEE Power & Energy Society General Meeting (PESGM).

[10]  Alessandro Astolfi,et al.  Conditions for stability of droop-controlled inverter-based microgrids , 2014, Autom..

[11]  A. Engler,et al.  CONTROL OF PARALLEL OPERATING BATTERY INVERTERS , 2001 .

[12]  A. I. Mees,et al.  Limit Cycle Stability , 1973 .

[13]  Gray Davis Integration of Distributed Energy Resources the Certs Microgrid Concept California Energy Commission , 2022 .

[14]  Yushi Miura,et al.  Cost-Function-Based Microgrid Decentralized Control of Unbalance and Harmonics for Simultaneous Bus Voltage Compensation and Current Sharing , 2019, IEEE Transactions on Power Electronics.

[15]  Robert H. Lasseter,et al.  Real-World Performance of a CERTS Microgrid in Manhattan , 2014, IEEE Transactions on Sustainable Energy.

[16]  Alireza Karimi,et al.  Robust distributed averaging frequency control of inverter-based microgrids , 2016, 2016 IEEE 55th Conference on Decision and Control (CDC).

[17]  Alan R. Wood,et al.  HVDC converter transformer core saturation instability: a frequency domain analysis , 1996 .

[18]  S. Sanders,et al.  Dynamic Phasors in Modeling and Analysis of Unbalanced Polyphase Ac Machines , 2002, IEEE Power Engineering Review.

[19]  G. C. Paap,et al.  Symmetrical components in the time domain and their application to power network calculations , 2000 .

[20]  Turhan Demiray,et al.  Simulation of Power System Dynamics using Dynamic Phasor Models , 2008 .

[21]  Xu-Dong Chen,et al.  Modelling and stability analysis of virtual synchronous machine using harmonic state‐space modelling method , 2019, The Journal of Engineering.

[22]  Josep M. Guerrero,et al.  Mitigation of Harmonics in Grid-Connected and Islanded Microgrids Via Virtual Admittances and Impedances , 2017, IEEE Transactions on Smart Grid.

[23]  Frede Blaabjerg,et al.  Harmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis , 2019, IEEE Transactions on Smart Grid.

[24]  Frede Blaabjerg,et al.  The modeling and harmonic coupling analysis of multiple-parallel connected inverter using Harmonic State Space (HSS) , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[25]  Malte John,et al.  Small signal impedance measurement in droop controlled AC microgrids , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[26]  A. M. Kulkarni,et al.  Dynamic Phasor Analysis of SSR Mitigation Schemes Based on Passive Phase Imbalance , 2011, IEEE Transactions on Power Systems.

[27]  Vinod Khadkikar,et al.  Direct Control of the Inverter Impedance to Achieve Controllable Harmonic Sharing in the Islanded Microgrid , 2017, IEEE Transactions on Industrial Electronics.

[28]  Josep M. Guerrero,et al.  Dynamic Phasors-Based Modeling and Stability Analysis of Droop-Controlled Inverters for Microgrid Applications , 2014, IEEE Transactions on Smart Grid.

[29]  R. Adapa,et al.  Control of parallel connected inverters in stand-alone AC supply systems , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[30]  T. Kawabata,et al.  Parallel Operation of Voltage Source Inverters , 1986, 1986 Annual Meeting Industry Applications Society.

[31]  G. Venkataramanan,et al.  Dynamic modeling and control of three phase pulse width modulated power converters using phasors , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[32]  Thomas M. Jahns,et al.  Coherency Identification and Aggregation in Grid-Forming Droop-Controlled Inverter Networks , 2019, IEEE Transactions on Industry Applications.

[33]  Giri Venkataramanan,et al.  Impedance matching based stability criteria for AC microgrids , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[34]  Giri Venkataramanan,et al.  On the choice of voltage regulators for droop-controlled voltage source converters in microgrids to ensure stability , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[35]  Peter W. Lehn,et al.  On Dynamic Evaluation of Harmonics Using Generalized Averaging Techniques , 2015, IEEE Transactions on Power Systems.