Dual-element needle transducer for intravascular ultrasound imaging

Abstract. A dual-element needle transducer for intravascular ultrasound imaging has been developed. A low-frequency element and a high-frequency element were integrated into one device to obtain images which conveyed both low- and high-frequency information from a single scan. The low-frequency element with a center frequency of 48 MHz was fabricated from the single crystal form of lead magnesium niobate-lead titanate solid solution with two matching layers (MLs) and the high frequency element with a center frequency of 152 MHz was fabricated from lithium niobate with one ML. The measured axial and lateral resolutions were 27 and 122  μm, respectively, for the low-frequency element, and 14 and 40  μm, respectively, for the high-frequency element. The performance of the dual-element needle transducer was validated by imaging a tissue-mimicking phantom with lesion-mimicking area, and ex vivo rabbit aortas in water and rabbit whole blood. The results suggest that a low-frequency element effectively provides depth resolved images of the whole vessel and its adjacent tissue, and a high-frequency element visualizes detailed structure near the surface of the lumen wall in the presence of blood within the lumen. The advantages of a dual-element approach for intravascular imaging are also discussed.

[1]  Thomas H Marwick,et al.  Screening for coronary artery disease in patients with diabetes: a Bayesian strategy of clinical risk evaluation and exercise echocardiography. , 2005, American heart journal.

[2]  D. A. Christopher,et al.  Advances in ultrasound biomicroscopy. , 2000, Ultrasound in medicine & biology.

[3]  MarkBrezinski,et al.  Index Matching to Improve Optical Coherence Tomography Imaging Through Blood , 2001 .

[4]  V. Fuster,et al.  Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo. , 1996, Circulation.

[5]  E. Bolson,et al.  Lumen Diameter of Normal Human Coronary Arteries: Influence of Age, Sex, Anatomic Variation, and Left Ventricular Hypertrophy or Dilation , 1992, Circulation.

[6]  M. Naghavi,et al.  New developments in the detection of vulnerable plaque , 2001, Current atherosclerosis reports.

[7]  Zahi A Fayad,et al.  Progression and Regression of Atherosclerotic Lesions: Monitoring With Serial Noninvasive Magnetic Resonance Imaging , 2002, Circulation.

[8]  Qifa Zhou,et al.  Integrated IVUS-OCT Imaging for Atherosclerotic Plaque Characterization , 2014, IEEE Journal of Selected Topics in Quantum Electronics.

[9]  Hiroto Tsujioka,et al.  Head to head comparison between the conventional balloon occlusion method and the non-occlusion method for optical coherence tomography. , 2011, International journal of cardiology.

[10]  P. Libby,et al.  The unstable atheroma. , 1997, Arteriosclerosis, thrombosis, and vascular biology.

[11]  N. Weissman,et al.  Plaque characterization with optical coherence tomography. , 2006, Journal of the American College of Cardiology.

[12]  Peter Barlis,et al.  Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition. , 2007, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[13]  G Tearney,et al.  Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: comparison with intravascular ultrasound. , 2001, Circulation.

[14]  Takahiko Suzuki,et al.  Safety and feasibility of an intravascular optical coherence tomography image wire system in the clinical setting. , 2008, The American journal of cardiology.

[15]  J. Fujimoto,et al.  Optical coherence tomography for optical biopsy. Properties and demonstration of vascular pathology. , 1996, Circulation.

[16]  C. Zarins,et al.  Compensatory enlargement of human atherosclerotic coronary arteries. , 1987, The New England journal of medicine.

[17]  N. Munce,et al.  Hybrid intravascular ultrasound and optical coherence tomography catheter for imaging of coronary atherosclerosis , 2013, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[18]  K. Shung,et al.  Piezoelectric films for high frequency ultrasonic transducers in biomedical applications. , 2011, Progress in materials science.

[19]  M. Davies,et al.  Relationship Between Coronary Artery Remodeling and Plaque Vulnerability , 2002, Circulation.

[20]  Qifa Zhou,et al.  Multi-frequency intravascular ultrasound (IVUS) imaging , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[21]  K. Seung,et al.  Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. , 2002, Journal of the American College of Cardiology.

[22]  Tetsuo Tsuchiya,et al.  Relationship Between Arterial and Fibrous Cap Remodeling: A Serial Three-Vessel Intravascular Ultrasound and Optical Coherence Tomography Study , 2010, Circulation. Cardiovascular interventions.

[23]  Jong Seob Jeong,et al.  Angled-focused 45 MHz PMN-PT single element transducer for intravascular ultrasound imaging. , 2015, Sensors and actuators. A, Physical.

[24]  Brett E. Bouma,et al.  In Vivo Characterization of Coronary Atherosclerotic Plaque by Use of Optical Coherence Tomography , 2005, Circulation.