In research on natural ventilation, and passive cooling with forced convection, is essential to know how heat flows in a solid object and the pattern of temperature distribution on their surfaces, and eventually how air flows through and convects heat from the surfaces of steel under roof. This paper presents some results from running the computational fluid dynamic program (CFD) by comparison between natural ventilation and forced convection within roof attic that is received directly from solar radiation. The CFD program for modeling air flow inside roof attic has been modified to allow as two cases. First case, the analysis under natural ventilation, is closed area in roof attic and second case, the analysis under forced convection, is opened area in roof attic. These extend of all cases to available predictions of variations such as temperature, pressure, and mass flow rate distributions in each case within roof attic. The comparison shows that this CFD program is an effective model for predicting air flow of temperature and heat transfer coefficient distribution within roof attic. The result shows that forced convection can help to reduce heat transfer through roof attic and an around area of steel core has temperature inner zone lower than natural ventilation type. The different temperature on the steel core of roof attic of two cases was 10-15 K. Keywords—CFD program, natural ventilation, forced convection, heat transfer, air flow.
[1]
Cezar O.R. Negrão.
Integration of computational fluid dynamics with building thermal and mass flow simulation
,
1998
.
[2]
H. Matsumoto,et al.
A laboratory experiment on natural ventilation through a roof cavity for reduction of solar heat gain
,
2008
.
[3]
Christian Inard,et al.
Prediction of air temperature distribution in buildings with a zonal model
,
1996
.
[4]
Kwang Woo Kim,et al.
An experimental study on airflow in the cavity of a ventilated roof
,
2009
.
[5]
Mohamed B. Gadi,et al.
Using CFD to investigate ventilation characteristics of vaults as wind-inducing devices in buildings
,
2008
.
[6]
Zhengen Ren,et al.
COwZ—A subzonal indoor airflow, temperature and contaminant dispersion model
,
2006
.
[7]
J. Tanny,et al.
Heat Fluxes and Airflow Patterns Through Roof Windows in a Naturally Ventilated Enclosure
,
2005
.
[8]
Zhengen Ren,et al.
Simulating air flow and temperature distribution inside buildings using a modified version of COMIS with sub-zonal divisions
,
2003
.
[9]
Helmut E. Feustel,et al.
COMIS—an international multizone air-flow and contaminant transport model
,
1998
.