Doppler shift measurements using Monte Carlo modeling

The most desired aim of clinical detection is to minimize the dimension of the detection instruments but still maintain high resolution and high precision. One of the most important mechanisms for maintaining the life of human beings is the human circulatory system. Thus, the research presented focuses on a non-invasive technique of photon measuring. From the measured results one can obtain important biomedical parameters for pathological diagnosis. This project is to implement a non-invasive optical flow velocimetry for detecting the human circulatory system under the skin surface. Then numerical simulation and model analysis of the transmission of photons on the skin surface is calculated via the Monte Carlo method. The source of the incidence photons is a He-Ne laser. The signal is transmitted and detected via a Y-type optical fiber. Optical heterodyning is used to measure the frequency difference between the reflection wave and the original incidence laser wave. This is a real time and continuous detection blood flow velocimetry. The authors find that this is a reliable tool for doctors when doing clinical diagnosis.

[1]  T Tanaka,et al.  Measurement of the Velocity of Blood Flow (in vivo) Using a Fiber Optic Catheter and Optical Mixing Spectroscopy. , 1975, Applied optics.

[2]  G. A. Holloway,et al.  An Instrument to Measure Cutaneous Blood Flow Using the Doppler Shift of Laser Light , 1978, IEEE Transactions on Biomedical Engineering.

[3]  A Yoshida,et al.  [The new laser Doppler velocimetry for the measurement of retinal circulation and its clinical application]. , 1996, [Hokkaido igaku zasshi] The Hokkaido journal of medical science.

[4]  B Chance,et al.  Intracellular oxidation-reduction state measured in situ by a multichannel fiber-optic surface fluorometer. , 1982, Science.

[5]  C. Riva,et al.  Laser Doppler measurements of blood flow in capillary tubes and retinal arteries. , 1972, Investigative ophthalmology.

[6]  T. Ryan,et al.  Laser Doppler imaging of skin microcirculation. , 1998, Acta dermato-venereologica.

[7]  D R Doiron,et al.  Porphyrin photodynamic therapy: principles and clinical applications. , 1986, Current problems in dermatology.

[8]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[9]  M. Stern,et al.  In vivo evaluation of microcirculation by coherent light scattering , 1975, Nature.

[10]  B L Petrig,et al.  Laser Doppler velocimetry study of retinal circulation in diabetes mellitus. , 1986, Archives of ophthalmology.

[11]  Wood Eh,et al.  Photoelectric determination of arterial oxygen saturation in man. , 1949 .

[12]  F.M. Ham,et al.  Determination of glucose concentrations in an aqueous matrix from NIR spectra using optimal time-domain filtering and partial least-squares regression , 1997, IEEE Transactions on Biomedical Engineering.

[13]  Toyoichi Tanaka,et al.  Blood Velocity Measurements in Human Retinal Vessels , 1974, Science.

[14]  J. Piau,et al.  Systemic sclerosis: blood rheometry and laser Doppler imaging of digital cutaneous microcirculation during local cold exposure. , 1998, Clinical hemorheology and microcirculation.