Exergetic analysis of a double stage LiBr–H2O thermal compressor cooled by air/water and driven by low grade heat

Abstract In the present paper, an exergetic analysis of a double stage thermal compressor using the lithium bromide–water solution is performed. The double stage system considered allows obtaining evaporation temperatures equal to 5 °C using solar heat coming from flat plate collectors and other low grade thermal sources. In this study, ambient air and water are alternatively used as cooling fluids without crystallization problems up to condensation–absorption temperatures equal to 50 °C. The results obtained give the entropy generated, the exergy destroyed and the exergetic efficiency of the double stage thermal compressor as a function of the absorption temperature. The conclusions obtained show that the irreversibilities generated by the double stage thermal compressor will tend to increase with the absorption temperature up to 45 °C. The maximum value corresponds to 1.35 kJ kg −1  K −1 . The entropy generated and the exergy destroyed by the air cooled system are higher than those by the water cooled one. The difference between the values increases when the absorption temperature increases. For an absorption temperature equal to 50 °C, the air cooled mode generates 14% more entropy and destroys 14% more exergy than the water cooled one. Also, the results are compared with those of previous studies for single and double effect air cooled and water cooled thermal compressors. The conclusions show that the double stage system has about 22% less exergetic efficiency than the single effect one and 32% less exergetic efficiency than the double effect one.

[1]  K. Ng,et al.  Entropy production analysis and experimental confirmation of absorption systems , 1997 .

[2]  Peter Lamp,et al.  European research on solar-assisted air conditioning , 1998 .

[3]  Giacomo M. Bisio,et al.  Thermodynamic analysis of the main devices for thermal energy upgrading , 1998 .

[4]  M. J. Moran,et al.  Thermal design and optimization , 1995 .

[5]  Felix Ziegler,et al.  Absorption cycles. A review with regard to energetic efficiency , 1993 .

[6]  M. Venegas,et al.  Thermodynamic study of multistage absorption cycles using low‐temperature heat , 2002 .

[7]  Alberto Coronas,et al.  Double-lift absorption refrigeration cycles driven by low-temperature heat sources using organic fluid mixtures as working pairs , 2001 .

[8]  Pierre Neveu,et al.  A comparative thermodynamic study of sorption systems: second law analysis , 1996 .

[9]  Antonio Lecuona,et al.  Compressors driven by thermal solar energy: Entropy generated, exergy destroyed and exergetic efficiency , 2002 .

[10]  Félix Hernández,et al.  The natural gas-absorption method system as an alternative to the electric power-mechanical compression system in Spain , 1993 .

[11]  Z. F Li,et al.  Solar absorption cooling with low grade heat source — a strategy of development in South China , 2002 .

[12]  B. Agnew,et al.  Exergy analysis: an absorption refrigerator using lithium bromide and water as the working fluids , 2000, Applied Thermal Engineering.

[13]  M. Venegas,et al.  Crystallization as a limit to develop solar air-cooled LiBr–H2O absorption systems using low-grade heat , 2004 .

[14]  Syed M. Zubair,et al.  Second law based thermodynamic analysis of ammonia-water absorption systems , 2004 .

[15]  Peter Lamp,et al.  Opportunities for sorption cooling using low grade heat , 1998 .