Visualizing Gait Patterns of Able bodied Individuals and Transtibial Amputees with the Use of Accelerometry in Smart Phones

Human gait analysis is used to indirectly monitor the rehabilitation of patients affected by diseases or to directly monitor patients under orthotic care. Visualization of gait patterns on the instrument are used to capture the data. In this study, we created a mobile application that serves as a wireless sensor to capture movement through a smartphone accelerometer. The application was used to collect gait data from two groups (able-bodied and unilateral transtibial amputees). Standard gait activities such as walking, running and climbing, including non-movement, sitting were captured, stored and analyzed. This paper discusses different visualization techniques that can be derived from accelerometer data. Removing gravity data, accelerometer data can be transformed into distribution data using periodicity; features were derived from histograms. Decision tree analysis shows that only three significant features are necessary to classify subject activity, namely: average of minimum peak values, student t-statistics of minimum peak values and mode of maximum peak values. We found that the amputee group had a higher acceleration and a lower skewness period between peaks of accelerations than the able-bodied group.

[1]  Begonya Garcia-Zapirain,et al.  Gait Analysis Methods: An Overview of Wearable and Non-Wearable Systems, Highlighting Clinical Applications , 2014, Sensors.

[2]  Gavriel Salvendy,et al.  Handbook of Human Factors and Ergonomics: Salvendy/Handbook of Human Factors 4e , 2012 .

[3]  Mihaela Baritz,et al.  Assessment of Human Bio-Behavior During Gait Process Using LifeMOD Software , 2010 .

[4]  Kosuke Okusa,et al.  Gait parameter and speed estimation from the frontal view gait video data based on the gait motion and spatial modeling , 2013 .

[5]  Bijan Najafi,et al.  The impact of footwear and walking distance on gait stability in diabetic patients with peripheral neuropathy. , 2013, Journal of the American Podiatric Medical Association.

[6]  Catherine A Macleod,et al.  Development and validation of a low-cost, portable and wireless gait assessment tool. , 2014, Medical engineering & physics.

[7]  A. Mirelman,et al.  Introducing a new definition of a near fall: intra-rater and inter-rater reliability. , 2014, Gait & posture.

[8]  A M O Bakheit,et al.  Comparison of three definitions of the mid-stance and mid-swing events of the gait cycle in children , 2006, Disability and rehabilitation.

[9]  Deborah Kartin,et al.  Beyond componentry: How principles of motor learning can enhance locomotor rehabilitation of individuals with lower limb loss--a review. , 2012, Journal of rehabilitation research and development.

[10]  Gavriel Salvendy,et al.  Handbook of Human Factors and Ergonomics , 2005 .

[11]  Gaia Rubbieri,et al.  Tools for Observational Gait Analysis in Patients With Stroke: A Systematic Review , 2013, Physical Therapy.

[12]  Nicolas Vuillerme,et al.  Does a Single Gait Training Session Performed Either Overground or on a Treadmill Induce Specific Short-Term Effects on Gait Parameters in Patients with Hemiparesis? A Randomized Controlled Study , 2013, Topics in stroke rehabilitation.

[13]  黄亚明 MedScape , 2009 .

[14]  Alan R De Asha,et al.  Understanding adaptive gait in lower-limb amputees: insights from multivariate analyses , 2012, Journal of NeuroEngineering and Rehabilitation.

[15]  Peter Wolf,et al.  Validity and Reliability of Accelerometer-Based Gait Assessment in Patients with Diabetes on Challenging Surfaces , 2012, Journal of aging research.

[16]  P. J. Valenciano,et al.  Correlation among the Visual Gait Assessment Scale, Edinburgh Visual Gait Scale and Observational Gait Scale in children with spastic diplegic cerebral palsy. , 2012, Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil)).

[17]  Toshiki Kobayashi,et al.  Kinetic Gait Analysis Using a Low-Cost Insole , 2013, IEEE Transactions on Biomedical Engineering.