Suppressing the effect of flexible deformation in virtual vascular intervention surgery

In virtual surgery of minimally invasive vascular intervention, the feedback force is transmitted by the flexible guide wire. The flexion deformation of the guide wire would cause force loss and system lag, which would affect the authenticity of the VR (virtual reality) training. The SMC (sliding mode control) strategy with delayed-output observe can be used to suppress the effect of flexible deformation, but the effect of flexible deformation would be larger when multi- flexible deformation. In this study, we add a Proportional plus integral (PD) compensator to the delayed-output observe to suppress the effect of multi-flexible deformation. Simulation experiment results prove that the improved control strategy can suppress the effect of flexible deformation. And the strategy can be used in most kinds of virtual surgeries to enhance the efficiency of VR training.

[1]  Yuan-Shin Lee,et al.  Investigating Human Performance in a Virtual Reality Haptic Simulator as Influenced by Fidelity and System Latency , 2012, IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans.

[2]  P. Lanzer,et al.  Catheter-based cardiovascular interventions , 2013 .

[3]  John Kenneth Salisbury,et al.  Stability of Haptic Rendering: Discretization, Quantization, Time Delay, and Coulomb Effects , 2006, IEEE Transactions on Robotics.

[4]  Caroline Jay,et al.  Modeling the effects of delayed haptic and visual feedback in a collaborative virtual environment , 2007, TCHI.

[5]  Jian Sun,et al.  State feedback and output feedback control of a class of nonlinear systems with delayed measurements , 2007 .

[6]  Kai-Yuan Cai,et al.  Tracking control for a velocity-sensorless VTOL aircraft with delayed outputs , 2009, Autom..

[7]  Xinkai Chen Adaptive sliding mode control for discrete-time systems , 2005 .

[8]  Michael Defoort,et al.  Sliding-Mode Formation Control for Cooperative Autonomous Mobile Robots , 2008, IEEE Transactions on Industrial Electronics.

[9]  Anthony G. Gallagher,et al.  Construct validation of a novel hybrid virtual-reality simulator for training and assessing laparoscopic colectomy; results from the first course for experienced senior laparoscopic surgeons , 2008, Surgical Endoscopy.

[10]  Nikolaos Kazantzis,et al.  Nonlinear observer design in the presence of delayed output measurements , 2005, Syst. Control. Lett..

[11]  Allison M. Okamura,et al.  Friction Compensation for Enhancing Transparency of a Teleoperator With Compliant Transmission , 2007, IEEE Transactions on Robotics.

[12]  Lucian Panait,et al.  The role of haptic feedback in laparoscopic simulation training. , 2009, The Journal of surgical research.

[13]  Allison M. Okamura,et al.  Force modeling for needle insertion into soft tissue , 2004, IEEE Transactions on Biomedical Engineering.

[14]  Guo-Ping Cai,et al.  Optimal tracking control of a flexible hub–beam system with time delay , 2006 .

[15]  Gábor Székely,et al.  Evaluation of a new virtual-reality training simulator for hysteroscopy , 2009, Surgical Endoscopy.

[16]  Marlies P. Schijven,et al.  European consensus on a competency-based virtual reality training program for basic endoscopic surgical psychomotor skills , 2010, Surgical Endoscopy.

[17]  Toshio Tsuji,et al.  Human hand impedance characteristics during maintained posture , 1995, Biological Cybernetics.

[18]  Doug A. Bowman,et al.  Evaluating Display Fidelity and Interaction Fidelity in a Virtual Reality Game , 2012, IEEE Transactions on Visualization and Computer Graphics.

[19]  Xinghuo Yu,et al.  SECOND‐ORDER TERMINAL SLIDING MODE CONTROL OF INPUT‐DELAY SYSTEMS , 2006 .

[20]  Walter Herzog,et al.  Feedback controlled force enhancement and activation reduction of voluntarily activated quadriceps femoris during sub-maximal muscle action. , 2012, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[21]  Xinkai Chen,et al.  Adaptive sliding mode control for discrete-time multi-input multi-output systems , 2006, Autom..

[22]  C. Karaliotas,et al.  When simulation in surgical training meets virtual reality , 2011 .

[23]  Shih-Tseng Lee,et al.  Development of an Augmented Reality Force Feedback Virtual Surgery Training Platform , 2011 .

[24]  Lucy Y. Pao,et al.  Isotropic force control for haptic interfaces , 2004 .

[25]  Yuanqing Xia,et al.  Robust Sliding-Mode Control for Uncertain Time-Delay Systems Based on Delta Operator , 2009, IEEE Transactions on Industrial Electronics.

[26]  Blake Hannaford,et al.  Control law design for haptic interfaces to virtual reality , 2002, IEEE Trans. Control. Syst. Technol..

[27]  Yuan-Shin Lee,et al.  Snapping algorithm and heterogeneous bio-tissues modeling for medical surgical simulation and product prototyping , 2007 .

[28]  Steven D. Wexner,et al.  Review of available methods of simulation training to facilitate surgical education , 2010, Surgical Endoscopy.