Volume correction in computed tomography densitometry for follow-up studies on pulmonary emphysema.

Lung densitometry in drug evaluation trials can be confounded by changes in inspiration levels between computed tomography (CT) scans, limiting its sensitivity to detect changes over time. Therefore our aim was to explore whether the sensitivity of lung densitometry could be improved by correcting the measurements for changes in lung volume, based on the estimated relation between density (as measured with the 15th percentile point) and lung volume. We compared four correction methods, using CT data of 143 patients from five European countries. Patients were scanned, generally twice per visit, at baseline and after 2.5 years. The methods included one physiological model and three linear mixed-effects models using a volume-density relation: (1) estimated over the entire population with one scan per visit (model A) and two scans per visit (model B); and (2) estimated for each patient individually (model C). Both log-transformed and original volume and density values were evaluated and the differences in goodness-of-fit between methods were tested. Model C fitted best (P < 0.0001, P < 0.0001, and P = 0.064), when two scans were available. The most consistent progression estimation was obtained between sites, when both volume and density were log-transformed. Sensitivity was improved using repeated CT scans by applying volume correction to individual patient data. Volume correction reduces the variability in progression estimation by a factor of two, and is therefore recommended.

[1]  W. MacNee,et al.  [Evaluation of emphysema progression as measured by computed tomography in patients with chronic obstructive pulmonary disease]. , 1996, Pneumonologia i alergologia polska.

[2]  B. Stoel,et al.  Repeatability of Lung Density Measurements with Low-Dose Computed Tomography in Subjects with &agr;-1-Antitrypsin Deficiency–Associated Emphysema , 2001, Investigative radiology.

[3]  G J Kemerink,et al.  Density resolution in quantitative computed tomography of foam and lung. , 1996, Medical physics.

[4]  N H Holstein-Rathlou,et al.  Volume adjustment of lung density by computed tomography scans in patients with emphysema , 2004, Acta radiologica.

[5]  A. Dirksen,et al.  Short‐term reproducibility of computed tomography‐based lung density measurements in alpha‐1 antitrypsin deficiency and smokers with emphysema , 2004, Acta radiologica.

[6]  B. Stoel,et al.  Detection of emphysema progression in alpha 1-antitrypsin deficiency using CT densitometry; Methodological advances , 2008, Respiratory research.

[7]  R. Stockley,et al.  Predictors of mortality in α1-antitrypsin deficiency , 2003, Thorax.

[8]  Jan Stolk,et al.  Comparison of the Sensitivities of 5 Different Computed Tomography Scanners for the Assessment of the Progression of Pulmonary Emphysema: A Phantom Study , 2004, Investigative radiology.

[9]  F D Thomas,et al.  Density patterns in the normal lung as determined by computed tomography. , 1980, Radiology.

[10]  E Kohda,et al.  Longitudinal follow-up study of smoking-induced lung density changes by high-resolution computed tomography. , 2000, American journal of respiratory and critical care medicine.

[11]  Jan Stolk,et al.  Optimization and Standardization of Lung Densitometry in the Assessment of Pulmonary Emphysema , 2004, Investigative radiology.

[12]  T. Louis,et al.  Feasibility of retinoids for the treatment of emphysema study. , 2006, Chest.

[13]  H A Vrooman,et al.  A randomized clinical trial of alpha(1)-antitrypsin augmentation therapy. , 1999, American journal of respiratory and critical care medicine.

[14]  E. Podgoršak,et al.  The use of CT densitometry to predict lung toxicity in bone marrow transplant patients. , 1989, International journal of radiation oncology, biology, physics.

[15]  Johan H C Reiber,et al.  Variability in Densitometric Assessment of Pulmonary Emphysema With Computed Tomography , 2005, Investigative radiology.

[16]  M. Okamoto,et al.  Decreased computed tomographic lung density during exacerbation of asthma , 2003, European Respiratory Journal.

[17]  H. Vrooman,et al.  Quantitative Analysis of Computed Tomography Scans of the Lungs for the Diagnosis of Pulmonary Emphysema: A Validation Study of a Semiautomated Contour Detection Technique , 1995, Investigative radiology.

[18]  J. Hogg,et al.  Report of a workshop: quantitative computed tomography scanning in longitudinal studies of emphysema , 2004, European Respiratory Journal.

[19]  R M Slone,et al.  Repeatability of quantitative CT indexes of emphysema in patients evaluated for lung volume reduction surgery. , 2001, Radiology.

[20]  E. Hoffman,et al.  Characterization of the interstitial lung diseases via density-based and texture-based analysis of computed tomography images of lung structure and function. , 2003, Academic radiology.

[21]  H Oeser,et al.  Measurement of Lung Density by Computed Tomography , 1978, Journal of computer assisted tomography.

[22]  H Putter,et al.  Correlation between annual change in health status and computer tomography derived lung density in subjects with α1-antitrypsin deficiency , 2003, Thorax.