Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study

Extracellular electrical stimulation (EES) of the central nervous system (CNS) has been used empirically for decades, with both fundamental and clinical goals. Currently, microelectrode arrays (MEAs) offer new possibilities for CNS microstimulation. However, although focal CNS activation is of critical importance to achieve efficient stimulation strategies, the precise spatial extent of EES remains poorly understood. The aim of the present work is twofold. First, we validate a finite element model to compute accurately the electrical potential field generated throughout the extracellular medium by an EES delivered with MEAs. This model uses Robin boundary conditions that take into account the surface conductance of electrode/medium interfaces. Using this model, we determine how the potential field is influenced by the stimulation and ground electrode impedances, and by the electrical conductivity of the neural tissue. We confirm that current-controlled stimulations should be preferred to voltage-controlled stimulations in order to control the amplitude of the potential field. Second, we evaluate the focality of the potential field and threshold-distance curves for different electrode configurations. We propose a new configuration to improve the focality, using a ground surface surrounding all the electrodes of the array. We show that the lower the impedance of this surface, the more focal the stimulation. In conclusion, this study proposes new boundary conditions for the design of precise computational models of extracellular stimulation, and a new electrode configuration that can be easily incorporated into future MEA devices, either in vitro or in vivo, for a better spatial control of CNS microstimulation.

[1]  Charles A. Miller,et al.  Electrode configuration influences action potential initiation site and ensemble stochastic response properties , 2003, Hearing Research.

[2]  Marc Olivier Heuschkel Fabrication of multi-electrode array devices for electrophysiological monitoring of in-vitro cell/tissue cultures , 2001 .

[3]  K. Svoboda,et al.  Sparse optical microstimulation in barrel cortex drives learned behaviour in freely moving mice , 2008, Nature.

[4]  L A Bullara,et al.  Electrical stimulation of the brain. III. The neural damage model. , 1975, Surgical neurology.

[5]  A. Leduc,et al.  A numerical solution of cylindrical coordinate Laplace’s equation with mixed boundary conditions along the axis of symmetry: Application to intracerebral stimulating electrodes , 1984 .

[6]  Pierre Meyrand,et al.  Multiple spontaneous rhythmic activity patterns generated by the embryonic mouse spinal cord occur within a specific developmental time window. , 2004, Journal of neurophysiology.

[7]  W. Theodore Brain stimulation for epilepsy , 2005, Nature Clinical Practice Neurology.

[8]  A. Hodgkin,et al.  A quantitative description of membrane current and its application to conduction and excitation in nerve , 1952, The Journal of physiology.

[9]  J.H. Meier,et al.  Simulation of multipolar fiber selective neural stimulation using intrafascicular electrodes , 1992, IEEE Transactions on Biomedical Engineering.

[10]  Steve M. Potter,et al.  Effective parameters for stimulation of dissociated cultures using multi-electrode arrays , 2004, Journal of Neuroscience Methods.

[11]  M. Brecht,et al.  Behavioural report of single neuron stimulation in somatosensory cortex , 2008, Nature.

[12]  Frank Rattay,et al.  Effective electrode configuration for selective stimulation with inner eye prostheses , 2004, IEEE Transactions on Biomedical Engineering.

[13]  Nicholas T. Carnevale,et al.  The NEURON Simulation Environment , 1997, Neural Computation.

[14]  D.B. McCreery,et al.  Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation , 1990, IEEE Transactions on Biomedical Engineering.

[15]  E. Zrenner Will Retinal Implants Restore Vision ? , 2002 .

[16]  Ursula van Rienen,et al.  Matching geometry and stimulation parameters of electrodes for deep brain stimulation experiments—Numerical considerations , 2006, Journal of Neuroscience Methods.

[17]  E. Perl,et al.  Microelectrode arrays for stimulation of neural slice preparations , 1997, Journal of Neuroscience Methods.

[18]  Enrico Marani,et al.  Extracellular stimulation window explained by a geometry-based model of the Neuron-electrode contact , 2002, IEEE Transactions on Biomedical Engineering.

[19]  J. Holsheimer,et al.  Excitation of dorsal root fibers in spinal cord stimulation: a theoretical study , 1993, IEEE Transactions on Biomedical Engineering.

[20]  T. Sejnowski,et al.  [Letters to nature] , 1996, Nature.

[21]  Dominique M Durand,et al.  Extracellular voltage profile for reversing the recruitment order of peripheral nerve stimulation: a simulation study , 2004, Journal of neural engineering.

[22]  J. McHardy,et al.  An approach to corrosion control during electrical stimulation , 1977, Annals of Biomedical Engineering.

[23]  C. McIntyre,et al.  Sources and effects of electrode impedance during deep brain stimulation , 2006, Clinical Neurophysiology.

[24]  Sébastien Joucla,et al.  The "mirror" estimate: an intuitive predictor of membrane polarization during extracellular stimulation. , 2009, Biophysical journal.

[25]  Ursula van Rienen,et al.  Choosing electrodes for deep brain stimulation experiments–electrochemical considerations , 2005, Journal of Neuroscience Methods.

[26]  Guenter W. Gross,et al.  Recording of spontaneous activity with photoetched microelectrode surfaces from mouse spinal neurons in culture , 1982, Journal of Neuroscience Methods.

[27]  Frank Rattay,et al.  Dipole Distance for Minimum Threshold Current to Stimulate Unmyelinated Axons With Microelectrodes , 2007, IEEE Transactions on Biomedical Engineering.

[28]  C. McIntyre,et al.  Cellular effects of deep brain stimulation: model-based analysis of activation and inhibition. , 2004, Journal of neurophysiology.

[29]  R. Plonsey,et al.  Development of a model for point source electrical fibre bundle stimulation , 1988, Medical and Biological Engineering and Computing.

[30]  J. Rauschecker,et al.  Sending Sound to the Brain , 2002, Science.

[31]  J. Rizzo,et al.  Multi-electrode stimulation and recording in the isolated retina , 2000, Journal of Neuroscience Methods.

[32]  J. B. Ranck,et al.  Specific impedance of rabbit cerebral cortex. , 1963, Experimental neurology.

[33]  Peter Fromherz,et al.  Sheet conductor model of brain slices for stimulation and recording with planar electronic contacts , 2002, European Biophysics Journal.

[34]  Allen Taflove,et al.  Incorporation of the electrode–electrolyte interface into finite-element models of metal microelectrodes , 2008, Journal of neural engineering.

[35]  Huxley Af,et al.  A quantitative description of membrane current and its application to conduction and excitation in nerve. 1952. , 1990 .

[36]  Pascal Mailley,et al.  A New 3-D Finite-Element Model Based on Thin-Film Approximation for Microelectrode Array Recording of Extracellular Action Potential , 2008, IEEE Transactions on Biomedical Engineering.

[37]  J. B. Ranck,et al.  THE SPECIFIC IMPEDANCE OF THE DORSAL COLUMNS OF CAT: AN INISOTROPIC MEDIUM. , 1965, Experimental neurology.

[38]  C. McIntyre,et al.  Extracellular stimulation of central neurons: influence of stimulus waveform and frequency on neuronal output. , 2002, Journal of neurophysiology.

[39]  M. Merello,et al.  Deep Brain Stimulation of the Subthalamic Nucleus for the Treatment of Parkinson's Disease , 2008 .

[40]  Johannes J. Struijk,et al.  Evaluation of the cable model for electrical stimulation of unmyelinated nerve fibers , 2001, IEEE Transactions on Biomedical Engineering.

[41]  L. Geddes,et al.  The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologist , 1967, Medical and biological engineering.

[42]  Bruce C. Wheeler,et al.  Neural recording and stimulation of dissociated hippocampal cultures using microfabricated three-dimensional tip electrode array , 2006, Journal of Neuroscience Methods.

[43]  C. Winfree,et al.  Spinal cord stimulation for the relief of chronic pain. , 2005, Current surgery.

[44]  A. Benabid,et al.  Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus , 1991, The Lancet.

[45]  Arthur Prochazka,et al.  Control of urinary bladder function with devices: successes and failures. , 2006, Progress in brain research.

[46]  J. Holsheimer,et al.  Optimum electrode geometry for spinal cord stimulation: The narrow bipole and tripole , 1997, Medical and Biological Engineering and Computing.

[47]  D. Bertrand,et al.  A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices , 2002, Journal of Neuroscience Methods.

[48]  O. Billoint,et al.  A 64-Channel ASIC for In-Vitro Simultaneous Recording and Stimulation of Neurons using Microelectrode Arrays , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[49]  B. Wheeler,et al.  Multisite hippocampal slice recording and stimulation using a 32 element microelectrode array , 1988, Journal of Neuroscience Methods.