In vivo measurement of volumetric wear of a total knee replacement.

A new Roentgen Stereophotogrammetric Analysis (RSA) system is reported; it can measure penetration of the metallic femoral component of a Total Knee Replacement (TKR) prosthesis into the polyethylene bearing on the tibial component. This system was used to analyse a study group of six Anatomic Graduated Components (AGC) knee prostheses more than 6 years post-implantation, and to compare with a control group of six newly implanted AGC prostheses. The volumetric loss of polyethylene was estimated by imaging each prosthesis at a series of different knee flexion angles. The mean difference between the RSA measured polyethylene bearing thickness and the manufacturer's quoted values for the control group was -0.03 mm (SD 0.17). The estimated linear penetration at 6.4 years in this prosthesis was determined to be 0.1 mm/year. Volumetric wear was estimated to be 600-700 mm(3)/year at 6.4 years, equating to approximately 100 mm(3)/year. This does not appear to be clinically significant amount of wear as this prosthesis has excellent survival at 10 years.

[1]  M A Ritter,et al.  Long-Term Followup of Anatomic Graduated Components Posterior Cruciate-Retaining Total Knee Replacement , 2001, Clinical orthopaedics and related research.

[2]  Niclas Börlin,et al.  Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model , 2002, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  M. Allen,et al.  Technical feasibility and precision of radiostereometric analysis as an outcome measure in canine cemented total hip replacement , 2004, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[4]  I C Burgess,et al.  Development of a six station knee wear simulator and preliminary wear results , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  John M. Kelly ULTRA-HIGH MOLECULAR WEIGHT POLYETHYLENE* , 2002 .

[6]  S. Shalaby,et al.  Study of creep behavior of ultra-high-molecular-weight polyethylene systems. , 1998, Journal of biomedical materials research.

[7]  A Unsworth,et al.  Wear in Retrieved Charnley Acetabular Sockets , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  H. Rubash,et al.  Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements. , 2000, Journal of biomedical materials research.

[9]  T. Ilchmann Radiographic assessment of cup migration and wear after hip replacement. , 1997, Acta orthopaedica Scandinavica. Supplementum.

[10]  C. Jewett,et al.  Degradation of mechanical behavior in UHMWPE after natural and accelerated aging. , 2000, Biomaterials.

[11]  Stefan M. Gabriel,et al.  Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy. , 1998, Clinical biomechanics.

[12]  W. Harris,et al.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. , 1992, The Journal of bone and joint surgery. American volume.

[13]  D W Murray,et al.  Which primary total knee replacement? A review of currently available TKR in the United Kingdom. , 1997, Annals of the Royal College of Surgeons of England.

[14]  R. Campbell,et al.  A radiological technique for the assessment of wear in prosthetic knee replacements , 2000, Skeletal Radiology.

[15]  D W Murray,et al.  In vivo measurement of total knee replacement wear. , 2004, The Knee.

[16]  T. Bauer Particles and periimplant bone resorption. , 2002, Clinical orthopaedics and related research.