Sequential processing from cell lysis to protein assay on a chip enabling the optimization of an F(1)-ATPase single molecule assay condition.

We developed an integrated protein assay device, "Single Molecule MicroTAS (SMM)," which enables cell lysis, protein extraction, purification, and activity assay. The assay was achieved at the single-molecule scale for a genetically engineered protein, F(1)-ATPase, which is the smallest known rotary motor. A cell lysis condition, with a wide range of applied voltages (50-250 V) and other optimized values (pulse width: 50 micros; duty: 0.01%; electrode gap: 25 microm; total flow rate: 5 microL min(-1)) provided a high enough protein concentration for the assay. Successively, the protein was extracted and purified by specific binding in a microfluidic channel. During the assay process, the diffusion effect of lysate between a two-phase laminar flow contributes to optimizing the single-molecule assay condition, because the concentration of the original lysate from the E. coli solution is too high to assay. To achieve the most efficient assay condition, the protein diffusion effect on the assay was experimentally and numerically evaluated. The results reveal that, in our experimental conditions, concentrations of F(1) and other contaminated effluents are optimized for the F(1) rotational assay at a channel position. The adenosine triphosphate (ATP)-driven rotation speed measured in the SMM was compatible with that obtained by conventional purification and assay. Such a sequential process from cell lysis to assay proves that the SMM is an example of a sample-in-answer-out system for F(1) protein evaluation.

[1]  L. Goldstein,et al.  Bead movement by single kinesin molecules studied with optical tweezers , 1990, Nature.

[2]  Young-Ho Cho,et al.  A continuous electrical cell lysis device using a low dc voltage for a cell transport and rupture , 2007 .

[3]  Yu-Cheng Lin,et al.  Electroporation microchips for continuous gene transfection , 2001 .

[4]  Dino Di Carlo,et al.  Reagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation. , 2003, Lab on a chip.

[5]  Hiroyuki Fujita,et al.  Microfabricated arrays of femtoliter chambers allow single molecule enzymology , 2005, Nature Biotechnology.

[6]  Zhao-Lun Fang,et al.  Integration of single cell injection, cell lysis, separation and detection of intracellular constituents on a microfluidic chip. , 2004, Lab on a chip.

[7]  Ronald D. Vale,et al.  Single-molecule analysis of kinesin motility reveals regulation by the cargo-binding tail domain , 1999, Nature Cell Biology.

[8]  Dino Di Carlo,et al.  On-chip cell lysis by local hydroxide generation. , 2005, Lab on a chip.

[9]  Steffen Hardt,et al.  Integrated polymer chip for two-dimensional capillary gel electrophoresis. , 2004, Lab on a chip.

[10]  Luke P. Lee,et al.  A novel high aspect ratio microfluidic design to provide a stable and uniform microenvironment for cell growth in a high throughput mammalian cell culture array. , 2005, Lab on a chip.

[11]  Michael P. Sheetz,et al.  Identification of a novel force-generating protein, kinesin, involved in microtubule-based motility , 1985, Cell.

[12]  Jongyoon Han,et al.  Two-dimensional protein separation with advanced sample and buffer isolation using microfluidic valves. , 2004, Analytical chemistry.

[13]  M. Gijs,et al.  Droplet-based DNA purification in a magnetic lab-on-a-chip. , 2006, Angewandte Chemie.

[14]  Dafu Cui,et al.  Microfabrication and characterization of porous channels for DNA purification , 2006 .

[15]  Yi-Kuen Lee,et al.  Using a micro electroporation chip to determine the optimal physical parameters in the uptake of biomolecules in HeLa cells. , 2007, Bioelectrochemistry.

[16]  Koen Visscher,et al.  Single-molecule techniques for drug discovery. , 2004, Assay and drug development technologies.

[17]  宁北芳,et al.  疟原虫var基因转换速率变化导致抗原变异[英]/Paul H, Robert P, Christodoulou Z, et al//Proc Natl Acad Sci U S A , 2005 .

[18]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[19]  M. Yamada,et al.  A microfluidic flow distributor generating stepwise concentrations for high-throughput biochemical processing. , 2006, Lab on a chip.

[20]  K. Jensen,et al.  A microfluidic electroporation device for cell lysis. , 2005, Lab on a chip.

[21]  T Kitamori,et al.  Integration of an immunosorbent assay system: analysis of secretory human immunoglobulin A on polystyrene beads in a microchip. , 2000, Analytical chemistry.

[22]  Mehmet Toner,et al.  A high-throughput microfluidic real-time gene expression living cell array. , 2007, Lab on a chip.

[23]  S. J. Lee,et al.  Micro total analysis system (μ-TAS) in biotechnology , 2004, Applied Microbiology and Biotechnology.

[24]  Hiroyuki Fujita,et al.  Highly coupled ATP synthesis by F1-ATPase single molecules , 2005, Nature.

[25]  Paul Yager,et al.  Cell lysis and protein extraction in a microfluidic device with detection by a fluorogenic enzyme assay. , 2002, Analytical chemistry.

[26]  Kazuhiko Kinosita,et al.  Direct observation of the rotation of F1-ATPase , 1997, Nature.

[27]  P Yager,et al.  Theoretical analysis of molecular diffusion in pressure-driven laminar flow in microfluidic channels. , 2001, Biophysical journal.

[28]  Takeshi Hatsuzawa,et al.  On-Chip Single-Cell Lysis for Extracting Intracellular Material , 2007 .

[29]  C. Klapperich,et al.  Thermoplastic microfluidic device for on-chip purification of nucleic acids for disposable diagnostics. , 2006, Analytical chemistry.

[30]  R. Rosenfeld Nature , 2009, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[31]  Masasuke Yoshida,et al.  Purine but Not Pyrimidine Nucleotides Support Rotation of F1-ATPase* , 2001, The Journal of Biological Chemistry.

[32]  G. Whitesides,et al.  Experimental and theoretical scaling laws for transverse diffusive broadening in two-phase laminar flows in microchannels , 2000 .

[33]  Edward O Haeggström,et al.  Microfluidic sonicator for real-time disruption of eukaryotic cells and bacterial spores for DNA analysis. , 2005, Ultrasound in medicine & biology.

[34]  Toshio Yanagida,et al.  A single myosin head moves along an actin filament with regular steps of 5.3 nanometres , 1999, Nature.

[35]  Gwo-Bin Lee,et al.  Integrated microfluidic systems for cell lysis, mixing/pumping and DNA amplification , 2005 .

[36]  Hiroyasu Itoh,et al.  Direct observation of DNA rotation during transcription by Escherichia coli RNA polymerase , 2001, Nature.

[37]  D. Root,et al.  Downscaling functional bioassays by single-molecule techniques. , 2006, Drug discovery today.

[38]  Mark Bachman,et al.  Fast electrical lysis of cells for capillary electrophoresis. , 2003, Analytical chemistry.

[39]  Dong-Chul Han,et al.  Electrotransfection of mammalian cells using microchannel-type electroporation chip. , 2004, Analytical chemistry.

[40]  A. Hudspeth,et al.  Movement of microtubules by single kinesin molecules , 1989, Nature.

[41]  R. Monticello,et al.  Effects of inducing expression of cloned genes for the F0 proton channel of the Escherichia coli F1F0 ATPase , 1992, Journal of bacteriology.

[42]  Y. Tai,et al.  A micro cell lysis device , 1999 .

[43]  K. Svoboda,et al.  Fluctuation analysis of motor protein movement and single enzyme kinetics. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[44]  Chih-Ming Ho,et al.  Electrokinetic bioprocessor for concentrating cells and molecules. , 2004, Analytical chemistry.

[45]  Masasuke Yoshida,et al.  The Role of the DELSEED Motif of the β Subunit in Rotation of F1-ATPase* , 2000, The Journal of Biological Chemistry.

[46]  Matthias Rief,et al.  Myosin-V is a processive actin-based motor , 1999, Nature.