Flash Glucose Monitoring: Differences Between Intermittently Scanned and Continuously Stored Data

The flash glucose monitoring system FreeStyle Libre (Abbott Diabetes Care Ltd., Witney, UK) measures interstitial glucose concentrations and continuously stores measurement values every 15 minutes. To obtain a current glucose reading, users have to scan the sensor with the reader. In a clinical trial, 5% of the scanned data showed relative differences of more than ±10% compared with continuously stored data points (median −0.5%). Such differences might impact results of studies using this system. It should be indicated whether scanned or continuously stored data were used for analyses. Health care professionals might have to differentiate between data reports from clinical software and the scanned data their patients are provided with. Additional information on these differences and their potential impact on therapeutic decisions would be helpful.

[1]  P. Geelhoed-Duijvestijn,et al.  Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial , 2016, The Lancet.

[2]  Sofia Dahlqvist,et al.  A Clinical Trial of the Accuracy and Treatment Experience of the Flash Glucose Monitor FreeStyle Libre in Adults with Type 1 Diabetes , 2017, Diabetes technology & therapeutics.

[3]  G. Freckmann,et al.  Accuracy Evaluation of Four Blood Glucose Monitoring Systems in Unaltered Blood Samples in the Low Glycemic Range and Blood Samples in the Concentration Range Defined by ISO 15197. , 2015, Diabetes technology & therapeutics.

[4]  H. Bilo,et al.  Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus , 2017, BMJ Open Diabetes Research and Care.

[5]  T. Bailey,et al.  The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System , 2015, Diabetes technology & therapeutics.

[6]  Joan Lee Parkes,et al.  Accuracy Evaluation of Five Blood Glucose Monitoring Systems: The North American Comparator Trial , 2013, Journal of diabetes science and technology.

[7]  R. Stimson,et al.  Flash Glucose Monitoring Improves Outcomes in a Type 1 Diabetes Clinic , 2017, Journal of diabetes science and technology.

[8]  Gerry Rayman,et al.  Flash Glucose-Sensing Technology as a Replacement for Blood Glucose Monitoring for the Management of Insulin-Treated Type 2 Diabetes: a Multicenter, Open-Label Randomized Controlled Trial , 2016, Diabetes Therapy.

[9]  A. Maran,et al.  Head-to-head comparison between flash and continuous glucose monitoring systems in outpatients with type 1 diabetes , 2016, Journal of Endocrinological Investigation.